-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
-
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
-
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
-
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
-
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
-
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-012
-
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Dual Bus 74-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-302
-
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
-
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXI 5A Fault Insertion Switch 10-Channel
40-196-001
-
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
PXI 16-Channel 4-Bus 2A Fault Insertion Switch
40-197A-002
-
This 16-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers.
-
Product
Dual Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-102
-
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-402
-
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
-
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
-
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A
40-194A-001
-
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PXI 5A Fault Insertion Switch 5-Channel
40-196-101
-
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
-
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch
40-190B-001
-
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Fault finder
The STaff™
-
The staff fault finder is designed to meet the demands of the professional troubleshooter but its simplicity and price make it a tool for anyone needing to locate cable faults. Arrows on the LCD screen direct the user to the fault with pinpoint accuracy. A reference indication also will aid the user in identifying multiple faults when present. Whether you are fault locating utility service line or locating a broken sprinkler wire, the STAFF is the professional's choice.
-
Product
Fault Location
-
They can occur when new, during commissioning of the cables or initial energization, or many years after the cables have been put into service. The types of faults can also vary considerably, from dead shorts (also sometimes called “bolted faults”) to a cable that has catastrophically faulted and completely blown open.
-
Product
Fault Locating
-
Schweitzer Engineering Laboratories, Inc.
The built-in fault-locating methods in SEL devices allow you to quickly identify faults, dispatch crews for repairs, and restore service faster. Traveling-wave fault-locating technology calculates the locations of temporary and permanent faults by measuring the arrival times of the naturally occurring traveling waves caused by a transmission line fault. Accurately detecting these waves requires ultra-high-resolution monitoring, and locating is accurate to within one tower span (±300 m). Impedance-based fault-locating technology calculates fault locations by detecting changes in line impedance as a result of a fault. Impedance-based locating is reliable and accurate to about 2 percent of a line’s total length.
-
Product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
-
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
Visual Fault Locators
-
Visual fault locators are used to identify problems with your fiber. GAOTek visual fault locators typically are applied for fiber tracing, fiber routine, and continuity checking. Imagine being able to easily identify when and where a fiber is breaking, bending, or when there’s a threat to the fiber layer.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
-
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
Fault Locator
REZAP MODULAR
-
REZAP MODULAR brings full REZAP functionality to fuse panels with severe space restrictions
-
Product
Visual Fault Locator
STC-VFL301
-
Shanghai Stone Communication tech Co., Ltd
STC-VFL301 is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network.
-
Product
Fault Locator
WEEZAP
-
WEEZAP is an LV vacuum circuit breaker combined with advanced measurement and protection capability.
-
Product
Cable Fault Finder
-
Techno Instrumentation (India) Private Limited
Magnetic and Acoustic signal strength through bar graph and digits on LCD.Coincidence feature gives distance to the fault in milliseconds.Easy, fast and accurate pinpointing of faults.
-
Product
Visual Fault Locator
VFL X5003
-
Constant & stable output powerLow battery warning, reminds users to change the battery timely.Long battery life (up to 40 hours with AAA batteries)Pocket size and light weight, easy to use.Re-changeable ceramic tube, to avoid returning to manufacturer for this small fault.
-
Product
Stimulus Induced Fault Testing
SIFT
-
SIFT allows for the analysis of numerous stimuli to identify speed, fault, and parametric differences in silicon. The heart of the SIFT technique revolves around intentionally disturbing devices with external stimuli and comparing the test criteria to reference parts or timing/voltage sensitivities. Synchronous interfacing is possible to any tester without any wiring or program changes. The system can be based on either a motorized probe station or portable microscope stand for test head applications.





























