Data Acquisition Systems
sense, log and store information. Also known as: DAS
See Also: Data Acquisition, PCI Data Acquisition, DAQ
-
Product
16-Channel Anti-Alias Low-Pass Filter Card
AAF-16
-
The AAF-16 is a 16-channel anti-alias low-pass filter card series for front-end signal conditioning in PC-based data acquisition systems.
-
Product
PXI High Density Mux 49 Channel 2 Pole
40-670A-021-49/2
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
SATA SSDs VPX & XMC Modules
-
Curtiss-Wright Defense Solutions
Curtiss-Wright Direct Attached Storage (DAS) products enable solid-state disks (SSD) to be incorporated in embedded computing system solutions for a wide range of deployed applications. DAS devices are connected to and used by only one host computer. These data solutions are scalable from 512 Gigabytes up to 64 Terabytes.
-
Product
Battery Portable Passive Intermodulation Analyzer
iPA Series
-
The iPA Series Passive Intermodulation (PIM) analyzer is the first battery powered PIM Test Analyzer versatile enough to support multiple test scenarios such as testing at the top of the tower, base of tower, roof top and in-building for DAS systems. This IEC compliant 20W, rugged, battery operated design includes a tablet computer in a ruggedized case for remote control. This allows hands-free dynamic testing that is safe and convenient. Add the optional Range to Fault (RTF) module to quickly identify the location of PIM and Return Loss sources.
-
Product
PXI 2 Amp Multiplexer, Single 64-Channel, 1-Pole
40-635A-001
Multiplexer Module
The 40-635A-001 is a single 64-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI High Density Multiplexer, 47-Channel, 2-Pole
40-640A-022-47/2
Multiplexer Module
The 40-640A-022-47/2 is a 47-channel, 2-pole MUX and is part of a series of high density multiplexer modules featuring a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
Data Acquisition System
Pixie-16
Data Acquisition Module
The Pixie-16 is a data acquisition system for nuclear physics and other applications requiring coincident radiation detection with large number of channels.
-
Product
PXI Single 44 x 4 Matrix 1 Pole Screened
40-523-021-S
Matrix Switch Module
The 40-523 module is configured as a 44x4 high density matrix with available reedrelay formats of 1-pole, 2-pole and 1-pole screened. The screened version is suitablefor switching signals up to 50MHz. Model 40-524 is a similar matrix, available insingle pole 46x4 format. Typical applications include signal routing in FunctionalATE and data acquisition systems. These PXI matrix cards are constructed using highreliability Ruthenium Electro-Plated Reed Relays, offering >10e8 operations togive maximum switching confidence with long life and stable contact resistance.
-
Product
Road Load Data / Durability
-
Vehicle Durability Testing and Road Load Data AcquisitionA road load data acquisition system from Dewesoft is a perfect vehicle durability testing solution for real-drive tests or tests on the road simulator test benches. Our advanced DAQ technologies will shorten time to test dramatically and make sure you get the correct measurements right the first time.
-
Product
PXI 2 Amp MUX, Single 16-Channel 2-Pole
40-635-102
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI MUX 2 Bank, 32 Channel Screened 1 Pole
40-610-021-S-2/32/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI/PXIe Very High Density Multiplexer, 24-Channel, 8-Pole
40-675B-002-24/8
Multiplexer Module
The 40-675B-002-24/8 (PXI) and the 42-675B-002-24/8 (PXIe) are 24-channel, 8-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. They use high quality electromechanical signal relays allowing each channel to switch current up to 1 A at 150 VDC/100 VAC. Connections are made via a front panel 200-pin connector.
-
Product
Software for Recordkeeping Reporting
RegPerfect
-
Data management is vital to your company's bottom line and mission critical environmental compliance goals. Today's environmental professionals must learn to do more with less when faced with budget constraints, rising operating costs, and staff reductions. TML helps environmental professionals around the world meet these challenges by offering RegPerfect Software.The Teledyne Monitor Labs RegPerfect® software system is a state of the art Data Acquisition Handling and Reporting Sytem. RegPerfect® is the culmination of more than 40 years of experience in the data acquisition system business. The software is designed to comply with the data collection, quality assurance, and reporting requirements of federal and local regulatory agencies. Operating in real time, this rugged platform provides the visibility, connectivity and securityfor all of your environmental and operational needs related to the performance of your Continuous Emission Monitoring (CEM) System. For the most recent updates to the software, please visit the Product Status page.
-
Product
PXI Dual 12x8 Matrix, 2 Pole Switching
40-522-022
Matrix Switch Module
Medium density PXI dual 12x8, 2-pole matrix - it is also available in reed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
Product
PXI MUX 4 Bank, 16 Channel Screened 1 Pole
40-610-021-S-4/16/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
Current to Digital
-
Analog Devices’ breakthrough current-to-digital converter technology is backed by award winning expertise to help solve your medical, industrial, and security application needs. Our high speed, high resolution ADC modules enable improved CT scanner data acquisition, photodiode sensors and power monitoring, spectroscopy, and high channel count data acquisition systems.
-
Product
Low Speed Daq & Industrial Recorders
-
Advanced software packages can be used with Yokogawa recorders, data acquisition instruments, and other measuring equipment to build an integrated PC-based data acquisition system. Ethernet communication interfaces support fast and easy connection to LAN environments, enabling remote monitoring applications and centralized back up services. Standard software for the configuration of measurement devices and applications offer easy set-up and minimizes preparation time. Yokogawa offers the right tools to simplify your applications.
-
Product
Sensing System
DAS
-
Our Distributed Acoustic Sensor(DAS) with excellent pattern recognition software can detect and locate the distributed thousanfs of acoustic events. Whenever any vibration or sound around its sensing fiber is detected, our DAS system will process the measured data in real-time and its pattern recognition software will recognize the types of the events, such as digging, pipeline leakage, fence breach, vehicle moving person walking. And, the detected events are reported to the alarm server to help operators take actions to protect theor facilities.
-
Product
PXI High Density Multiplexer, 4-Bank, 20-Channel, 1-Pole
40-615A-016
Multiplexer Module
The 40-615A-016 is a 4-bank, 20-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
PXI High Density Multiplexer, 1-Bank, 64-Channel, 1-Pole, Screened
40-610A-016
Multiplexer Module
The 40-610A-016 is a screened 64-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI 2 Amp Multiplexer, Dual 16-Channel, 1-Pole
40-635A-105
Multiplexer Module
The 40-635A-105 is a dual 16-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI 32x8 Matrix Module, 2-Pole, 2A, 60W
40-580-001
Matrix Switch Module
The 40-580 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 32x8 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 160 pin DIN 41612 connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.
-
Product
Portable Conductivity/TDS/RS232 Meter with DAS
CyberScan CON 110
-
Single & Multi-point Automatic or Manual Calibration for quick and easy calibration±1% Full Scale Accuracy for precise and accurate measurements
-
Product
Temperature Data Acquisition
THERMES-USB
-
Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)
-
Product
PXI 4 Banks of 20 Channel 2 Pole MUX
40-615-022-4/20/2
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
Miniature Axial Extensometers
Model 3442
-
Jinan Testing Equipment IE Corporation
Weighing as little as 8 grams, these miniature extensometers are designed to have very low operating force with minimal specimen influence. All use an improved version of Epsilon’s dual flexure design which makes them very rugged for their size. With a module height of 15.2 mm (0.6 inches), they will fit in the limited space between grips that is typical with small test samples. Gauge lengths can be as short as 3 mm or as long as 50 mm. A newly designed gage setting pin and assembly allows the gauge length to be set accurately and repeatably to ASTM and ISO requirements for all gauge lengths. Reengineered quick attach wire forms provide simple and secure specimen attachment. Wire forms for round and flat specimens are included, as well as flat, 3-point, and vee knife edges. The wire forms may be removed to enable mounting using elastic bands or springs. A tethering attachment point provides fall protection and enables counterbalancing of the extensometer’s weight when testing delicate specimens.Model 3442 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller and Epsilon will equip the extensometer with a compatible connector wired to plug directly into the controller. For systems lacking the required electronics, Epsilon can provide a variety of solutions for signal conditioning and connection to data acquisition systems, chart recorders, or other equipment.
-
Product
PXI High Density Multiplexer, 2-Bank, 40-Channel, 1-Pole
40-615A-017
Multiplexer Module
The 40-615A-017 is a 2-bank, 40-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
Instrumented Pendulum Impact Testing System
JB(INSTRUMENTED)
-
Jinan Testing Equipment IE Corporation
JB-450I/750I Instrumented Pendulum Impact Testing Machine is equipped with high precision instrumented strain-gauged striking edge & high-speed data acquisition system. This instrumented test system can measure the force of a test specimen during an impact event. Then, the instrumented test data can be used to calculate the energy absorbed by the test specimen. In addition, the crack initiation and arrest loads can be used in fracture mechanical models.
-
Product
PXI 2A Multiplexer, 1-Bank, 16-Channel 8-Pole
40-614-018
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.




























