EM
-
Product
EMF Measurements/EM Measurements/Electromagnetic Radiation
-
Holland Shielding Systems B.V.
Electromagnetic fields cause interference in electronic devices and may affect the health of people close to where the fields are generated. It is important to recognize this at an early stage in a construction process, for instance at a future construction location or while construction is already underway, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by GSM, UMTS antennas and transformer spaces, to mention a few examples. These measurements can help determine the best location in the new building for rooms where sensitive measurements are to take place, e.g. in hospitals or nano laboratories. And last but not least, field-strength measurements can detect sources of interference and can be part of a scheduled check of existing screened spaces and Faraday cages.
-
Product
Power Relays
-
Replace your large, slow, unreliable EM relays with the Ideal Switch. Enable a new era of connected and better protected buildings (residential, commercial, hospitals, airports), transportation (eMobility, Rail, Marine), factories (Robots and Systems), and power distribution (solar, wind, grid, battery).
-
Product
RF Architectural Shielding Products
-
EMI (Electromagnetic Interference) is often used interchangeably with RFI (Radio Frequency Interference). However, EMI can be any frequency of electromagnetic noise, whereas RFI is a relatively narrow range of electromagnetic noise on the EM spectrum. EMI Shielding can be used to mitigate electric and magnetic radiation across various spaces. Radio Frequency (RF) Shielding can be used to mitigate RFI with specifically designed enclosures that can block RFI. As well, RF Shielding can include application of RF Shielding paints, fabrics, and other materials.
-
Product
High Frequency Electromagnetic Software
Sonnet Suites
-
The Sonnet® Suites™ develop precise RF models (S-, Y-, Z-parameters or extracted SPICE model) for planar circuits and antennas. The software requires a physical description of your circuit (arbitrary layout and material properties for metal and dielectrics), and employs a rigorous Method-of-Moments EM analysis based on Maxwell's equations that includes all parasitic, cross-coupling, enclosure and package resonance effects.
-
Product
Propagation Software
Wireless InSite
-
Wireless InSite is a suite of ray-tracing models and high-fidelity EM solvers for the analysis of site-specific radio propagation and wireless communication systems. The software provides efficient and accurate predictions of EM propagation and communication channel characteristics in complex urban, indoor, rural and mixed path environments.
-
Product
Antennas
-
A specialized transducer that converts electric current into electromagnetic (EM) waves or vice versa.
-
Product
IQ Modulator
IQM Series
-
*Capable of receiving from DC to 500 MHz, LO inputs, outputting RF frequencies *Internal low noise oscillator *Internal reference *Buffered modulator Balanced IQ *Optimized for low EVM *Internal Reference Detect Switch Optional (EM Research RDS Series) *Up to 250 mega-symbols per second
-
Product
EM Tracking Products
-
The strength of the Aurora and 3D Guidance electromagnetic tracking solutions lies in their similarities and their differences. Both can provide unobstructed in-vivo tracking of OEM medical instruments, share exceptional measurement accuracy and reliability and are engineered and manufactured to deliver unparalleled tracking performance. Between them, there are seven different field generators with unique measurement volumes, and 20 standard sensor offerings (plus custom options). While the Aurora has 6DOF and 5DOF sensors, the 3D Guidance solution specializes in 6DOF tracking. 6DOF sensors are usually re-processable; 5DOF can be disposable. Some of our field generators are portable, while others seamlessly integrate into the medical OEM’s procedural cart or operative table. These differences provide near-countless opportunities to customize and integrate the Aurora and 3D Guidance solutions – all while benefiting from a shared foundation of technical excellence and expert product execution.
-
Product
Free Feature-Limited Version of Sonnet''s Professional Sonnet Suite
Sonnet Lite™
-
Sonnet Lite™ is a free feature-limited version of Sonnet''s professional Sonnet Suites, which provides EM analysis to thousands of companies across the globe. Many major manufacturers of high-frequency components and boards depend on Sonnet to analyze their predominantly planar high-frequency designs from 1 MHz through several THz.
-
Product
Electron Diffraction System
-
Modern physics is the post-Newtonian conception of physics. It implies that classical descriptions of phenomena are lacking, and that an accurate, " Modern", description of nature requires theories to incorporate elements of quantum mechanics or relativity, or both. This section includes many of the most important experiments in physics, including e/m tubes, the Franck-Hertz experiment, and nuclear magnetic resonance (NMR)
-
Product
Electron Microscope Sample Preparation
-
Excellent sample preparation is the prerequisite for first-class electron microscopy. Be prepared – for great results in EM Sample Preparation! Perfect preparation makes the difference between trying and achieving, between failure and success, between results and excellent results. So be prepared for great results with Leica Microsystems!
-
Product
Handheld 1-D electro-magnetic current meter for rivers
AEM1-DA
-
AEM1-DA is a 1-D electro-magnetic (EM) current meter for the flow measurements in rivers, streams and various waterways. The measurement range is 0 to 5m s-1. The EM sensor can accurately measure water speeds at a shallow depth of 3cm. The display unit has a 2MB flash memory so that the data are saved with calendar information (up to 255 station data). In comparison with conventional propeller-type current meter, AEM1-DA is robust and extremely easy to be operated and maintained.
-
Product
Navigation Information System
Nav-IS
-
Aeronautical & General Instruments Ltd.
Nav-IS combines a single or dual axis EM Speed Log with a range of Meteorological System options for a low cost, integrated solution. Using the latest proven and in service solid state sensor technology, this innovative, cost-effective and accurate system has been specifically developed for all applications from ocean-going merchant and passenger vessels to offshore patrol, coastguard and naval support vessels.
-
Product
EMCCD Image Sensors for Space and Ground-based Astronomy
-
EM (Electron Multiplication) is a technology that uses on-chip gain in the charge domain to effectively eliminate read noise from an image sensor. This enables advanced ultra-low light applications that require extreme sensitivity at fast frame rates such as adaptive optics and lucky imaging™.The combination of Teledyne e2v’s back-thinning technology and anti-reflection coatings enables industry leading quantum efficiency that can be optimised for applications in the visible, UV or NIR wavelength ranges.
-
Product
Electromagnetic
Promis 10
-
The Promis device is a multi-frequency, multi-spacing 3 component slingram type EM System for sounding and profiling the soil. This system features a transmitter loop to produce a primary magnetic field that will induce eddy current in conductive materials. These eddy currents will generate a secondary magnetic field that will be measured with the receiver loop. This system measures the in-phase and the out-of-phase components of the secondary magnetic field.
-
Product
Antenna, Omni-Directional Wideband Discone
EM-6105-1 | 30 MHz – 3 GHz
-
Electro-Metrics EM-6105-1 is a broad-band vertical co-linear array. It provides very wide frequency range omni-directional coverage in a single package. The antenna collapses for convenient storage and transport.
-
Product
Antenna, Log Periodic
EM-6947 | 200 MHz – 5 GHz
-
The EM-6947 is an ultra-wide bandwidth log periodic dipole array aimed at applications requiring consistent performance over a very wide frequency range. Capable of both receiving and moderate power level transmitting, the EM-6947 can take the place of two or more conventional antennas, allowing you to take full advantage of the tuning range capabilities of modern receiver and spectrum analyzer designs with less inconvenience caused by the need to switch antennas.
-
Product
Antenna, Biconical
EM-6912A | 30 Mhz – 300 MHz
-
A balun, feedline, and element cage give the Electro-Metrics EM-6912A response curves that are almost linear, making it ideal for swept measurements. An added benefit is that the EM-6912A has an improved BALUN design, which makes it insensitive to changes of orientation while vertically polarized. Readings obtained will be the same no matter which element is closest to the ground plane, eliminating a potential source of measurement error.
-
Product
Antenna, Omni Directional Wideband
EM-6851 | 2 GHz – 18 GHz
-
The EM-6851 Omni-Directional Wideband Antenna is capable of operating as either a transmitting or receiving antenna over the 2 to 18 GHz frequency range. This antenna provides a 45% size reduction when compared to similarly performing models. The antenna is enclosed in a weather resistant radome. The length of the support rod allows a microwave amplifier to be connected directly to the output connector, reducing the potential signal loss compared to an amplifier connected at a more distant point.
-
Product
Antenna, Log Periodic
EM-6944 | 200 MHz – 3 GHz
-
The EM-6944 offers an exceptional combination of frequency coverage from 200 MHz – 3 GHz and high power handling capability without compromising the consistent performance versus frequency that makes the log periodic antenna so desirable for test applications.
-
Product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
-
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
Product
Antenna, High Field Biconical
EM-6913 | 20 MHz – 300 MHz
-
The Electro-Metrics EM-6913 can be used for generating high intensity fields as required for EMC immunity testing 20 MHz to 300 MHz.
-
Product
Antenna, Log Periodic
EM-6951 | 300 MHz – 1 GHz
-
The Electro-Metrics EM-6951 Log Periodic Antenna was designed to operate over the 300 MHz to 1 GHz frequency range.
-
Product
Antenna, Tactical, Log Periodic
EM-6942 | 400 MHz – 4 GHz
-
The EM-6942 is designed for harsh environmental conditions and its folding elements and 2-section design simplifies transport and storage. The antenna can be mounted on a tripod or any ¼-20 mount and be positioned for horizontal or vertical polarization.
-
Product
Antenna, Log Periodic
EM-6936 | 700 MHz – 1300 MHz
-
The Electro-Metrics EM-6936 Log Periodic Antenna operates over the 700 MHz – 1300 MHz frequency range.
-
Product
Antenna, Log Periodic
EM-6939 | 800 MHz – 20 GHz
-
The Electro-Metrics EM-6939 Log Periodic Antenna operates over the 800 MHz – 20 GHz frequency range.
-
Product
Antenna, Octave Band Horn
EM-7022 | 4 GHz – 10 GHz
-
Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.
-
Product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
-
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
Product
Antenna, Wideband Discone
EM-6115 | 10 KHz – 2 GHz
-
The EM-6115 is a broad band collinear array allowing very wide Omni-Directional frequency coverage in a single package. Below approximately 100 MHz, the EM-6115 acts as an active vertical rod which offers 10 to 12 dB Greater unsaturated instantaneous dynamic range than competitive antennas (overload field strength: 2 V/meter) which greatly reduces intermodulation generated signals in a typical read world RF environment. In the congested spectrum above 100 MHz the antenna is passive and contributes no intermodulation products so the overload point is determined solely by the receiving instrument. This immunity to overload can often make the difference between useful signal output and an indecipherable jumble of spurious products and is accomplished without compromising sensitivity. The antenna collapses for convenient storage and transport.