RTD
- variable-resistance sensor measuring temperature by fluctuations in resistance.
-
Product
3-Slot Data Acquisition Mainframe With Three 20-Channel Multiplexer Modules
DAQ970MB
Mainframe
The DAQ970MB Good Multiplexer Bundle offer includes a DAQ970A three-slot data acquisition mainframe and three 20-channel DAQM901A multiplexer modules. This bundle provides the following:3-slot mainframe with USB and LAN6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
Product
Temperature Transmitter
Series 651
-
Linearized output for precise temperature monitoring or control is combined with small size and quick, easy mounting. Rugged Series 651 Transmitters are designed for use with 2 or 3-wire Pt100 RTDs (to DIN standard 43760 or BS1904) or ungrounded Type K thermocouples
-
Product
2Wire Temp Transmitter
TS
-
● Accuracy: RTD: 0.5%, T/C: 0.75%● Wide selection of input● Low output ripple● High stability & low cost
-
Product
PC/104 8-Channel Smart Sensor Interface
518
-
Measures thermocouples, RTDs, strain gages, thermistors, 4-20 mA, voltage and resistance 8 high-accuracy differential input channels Integral sensor excitation Exclusive pulsed excitation minimizes sensor self-heating Configurable sensor type per channel Fully electronic calibration Low power
-
Product
PXI-2720, 8-Bit, 10-Channel PXI Programmable Resistor Module
781985-20
Programmable Resistor Modules
8-Bit, 10-Channel PXI Programmable Resistor Module—The PXI‑2720 is a test module that replicates the behavior of resistance-based inputs and outputs such as potentiometers, resistance temperature detectors (RTDs), voltage dividers, and bridge elements. The PXI‑2720 programmatically controls a series of relays to vary the resistance across each channel of an I/O connector. This function is well suited for simulating environmental conditions in hardware‑in‑the‑loop (HIL) validation. The software provides a simple user interface that accepts inputs in units of temperature or resistance and configures the resistance across each channel.
-
Product
Trip Amplifiers
-
Datexel manufacture a large range of Trip Amplifiers and Process Limit Alarms that accept universal inputs and provide either relays or NPN or PNP transistor outputs. The DAT5028 is also an isolated signal converter and has a local display with up to 4 relays and is DIP switch programmable. The inputs can be Thermocouples, RTD, mV, mA, Resistance, Potentiometers or Voltage. They can be supplied fully configured set up by PC or DIP switches. The DAT5024 is a trip Amplifier / Temperature limit alarm for RTD's, Thermocouples, Voltage, Resistance and Current with the option of 1 or 2 relay outputs hysteresis and delay timers. The DAT5024 E range is an economical choice with DIP Switch programmable for voltage or current input. Either 1 relay or 2 relays (SPDT) are available with delay timers.
-
Product
Multifunction Counter (Pulse Input)
CM1-CT
-
CM1-CT multifunction counter(position) display controller, is design to have 2 pulse input, for proximity switch, photoelectric sensor, encoder etc.. Counting increase or decrease, positioning batch count etc.. display, with External input and Modbus communication port.Multiple types of input mode, trip mode setting to fulfil easy usage and requirement for counter controller. For different requirement, the meter can be with 2 relay or 1 Analogue output or 1 RS485(Modbus RTD mode) communication. (Choose 1 kind of output from the 3 options)
-
Product
Telemetry
-
Single channel system, offering wireless transfer of a single analogue signal, either 4-20mA or DC voltage. Mixed signal radio telemetry solution. Analogue I/O: 2x 2-40mA or DC Voltage. Digital I/O: 2x volt free or optional pulse counting required. Multi-channel radio telemetry system, 4 Analogue and 8 digital inputs. Significant signal connectivity and data transfer in a standard package.12 I/O channels allow greater signal monitoring capability SENSOR LINK Compact wireless telemetry link for any strain gauge sensor or RTD. Transmissions distance 1 to 300 meters. Licence free radio operation.16 bit ADC resolution.
-
Product
PXI Temperature Input Module
Module
PXI Temperature Input Modules offer up to 32 channels of analog temperature measurements. Some models include autozero channels for offset compensation as well as open thermocouple detection to identify disconnected thermocouples, while others support 2-, 3-, or 4-wire resistance temperature detector (RTD) measurements. PXI Temperature Input Modules support both high-speed and high-resolution modes. You can program channel configurations and scale measured data into engineering units.
-
Product
PXI RTD Simulator Module 12-Channel PT1000
40-262-202
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
Suitable For Temperature And Potentiometer Sensors
SEM1600T
-
The SEM1600T accepts resistance or mV signals from RTD, Slidewire or Thermocouple sensors.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Portable Process & Pressure Instruments
-
Time Electronics offer a range of portable process instruments for field and laboratory use. Products include temperature calibrators and simulators for RTD and PT100 applications, and loop instruments for field instrumentation testing of transmitters, transducers and sensors.
-
Product
8-Ch RTD Input IDAQ Module
iDAQ-815
-
Hot-swappable in iDAQ system8-ch simultaneous RTD sampling24-bit resolutionMultiple supported RTD types and connection typesIsolation protection up to 600VRMS
-
Product
Calibration Software
-
AMETEK Sensors, Test & Calibration
Our calibration software provides an easy way to calibrate gauges, RTD´s, thermocouples, transmitters, thermoswithes, and pressure switches. Complete a full calibration from entering the details of the gauge to printing out a calibration certificate. Reduce operating time by automating calibration procedures, reduce sources of error by automatically reading and storing values from the reference, and customize certificate templates to fit your needs.
-
Product
Temperature Data Logger
-
The temperature recording in a process is the most common and widely required application in any process. The commonly used temperature sensors are RTD Pt100 / Pt1000/ Cu53 / Thermistors and different kinds of Thermocouple. In order to avoid electromagnetic interference, the temperature signal is converted to 4-20mA and is carried to the logger. Our range of Temperature Data Logger includes Temperature Humidity Logger, RTD Data Logger, Thermocouple Data Logger and Flameproof Data Loggers.
-
Product
PXI-2722,16-Bit, 5-Channel PXI Programmable Resistor Module
781985-22
Programmable Resistor Modules
16-Bit, 5-Channel PXI Programmable Resistor Module—The PXI‑2722 is a test module that replicates the behavior of resistance-based inputs and outputs such as potentiometers, resistance temperature detectors (RTDs), voltage dividers, and bridge elements. The PXI‑2722 programmatically controls a series of relays to vary the resistance across each channel of an I/O connector. This function is well suited for simulating environmental conditions in hardware‑in‑the‑loop (HIL) validation. The software provides a simple user interface that accepts inputs in units of temperature or resistance and configures the resistance across each channel.
-
Product
3-Slot Data Acquisition Mainframe With GPIB, Three 20-Channel Multiplexer Modules, And BenchVue DAQ Software
DAQ973MBX
Mainframe
The DAQ973MBX Best Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe, three 20-channel DAQM901A multiplexer modules, and a BV0006B BenchVue DAQ software with a KeysightCare software support subscription. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2-and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning measures thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance36-month node-lock BV0006B BenchVue DAQ software license with KeysightCare software support subscription
-
Product
Resistance Temperature Detectors
-
Sensors used to measure temperature by correlating the resistance of the RTD element with temperature.
-
Product
Cryogenic Temperature Sensors
Ultra-low temperature Rox™
-
With the amazing progress made by dilution refrigerator manufacturers to push base temperatures well below 10 mK, the need for accurate, simplified temperature measurements continues to grow. The RX-102B-RS meets this need as a resistive temperature device (RTD) that maintains sensitivity well below 10 mK.
-
Product
PXI RTD Simulator Module, 8 Channel, PT100
40-263-401
Simulator
The 40-263-401 is an 8-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module, 8 Channel, PT1000
40-263-403
Simulator
The 40-263-403 is an 8-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
CAN PT MiniModule evo
-
CSM offers these modules for temperature measurements with increased accuracy requirements compared to thermocouples. PTMM evo modules allow high-precision temperature measurements with either PT100 or PT1000 RTD elements.
-
Product
Resistance Temperature Detectors - RTDs
-
Ashcroft® RTD sensor assemblies monitor temperature in industrial, process and hazardous installations. Available with Pt 100 and Pt 1000 RTDs, they are designed for use with either DIN 43772/T.2 or ISA-ds 49 style thermowells along with DIN and ASME type lag extensions. A wide selection of aluminum and 316 stainless steel connection heads make these RTDs configurable to the requirements of nearly any installation.
-
Product
Digital Multimeters
-
*5½-digit resolution to 8½-digit resolution DMMs*6ppm basic voltage measurement accuracy on the 8½-digit DMM for calibration laboratories*Fast, 1 Msample/s sampling speed to capture complex, low level current profiles from IoT devices or other wireless devices*Sensitivity of 1 µΩ and 1 pA to test low power devices for research, design, and manufacturing test*A wide range of measurement functions such as DC and AC volts, DC and AC current, two- and four-wire Ohms, continuity, frequency, period, RTD, thermistor, and thermocouple temperatures, diode test, and capacitance*Numerous interface options including LAN/LXI, USB-TMC, GPIB, and RS-232 for data acquisition and automated testing*Intelligence to execute tests and create customized measurements with minimal PC interaction*Measurement expansion up to ten channels
-
Product
Reference Thermapen®
-
Until now you would have spent hundreds more to get this level of accuracy in a NIST-Traceable standards thermometer. Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
Product
Dry Block Calibrators
-
Nagman Instruments & Electronics Pvt. Ltd
Dry Block calibrators are used for the most accurate calibration of temperature devices. Ideal for quick / fast Site Calibration of RTDs / Bi Metal Thermometers, Temperature Switches / Indicators etc. in Industrial & Marine Applications. Dry block calibrators can be used for a very wide range of temperature from – 100°C to over 1500°C. Nagman hosts a range of calibrators that are Stable, portable, heavy duty and budget friendly.
-
Product
Reference Cells For PIV-IV Systems
-
NREL calibrated cell used for calibration transfer.The Abet Technologies solar reference cell is a precision instrument for the determination of solar simulator irradiance levels. The sensor is a mono-crystalline silicon solar cell having an area of2x2cm(4cm).The back of the solar cell is attached to the device in such a way that a good heat transfer to the device housing is guaranteed. Below the solar cell a Pt100 RTD temperature sensor is mounted to allow monitoring of device temperature. The device is not shunted allowing the whole IV-curve to be measured. The solar cell is protected by a high quality fused silica window, assuring spectral sensitivity over a 320 -1100 nm range.
-
Product
Multi-Channel Telemetry
-
The AT7000 multi-channel systems can combine any customized mix of ordinary sensors: strain gages, thermocouples, RTDs, accelerometers, as well as motor/generator field voltages, currents and ground fault currents. The received data is continuously streamed to the user as analog (+/- 10V or 4/20mA) or digital data.