AC Load Banks
source for testing and measurement of current, voltage and frequency.
See Also: Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks, Resistive Load Banks, UPS
-
product
PXI Electronic Load Module
PXI Electronic Load Module provides the electronic load capabilities of sinking DC power with high-accuracy measurements in a compact form factor optimized for design validation, characterization, and production test.
-
product
300 Watt Electronic Load Module
N3304A
The Keysight N3304A is a 300 W (0-60A, 0-60V)electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3304A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3304A can also digitize waveforms.
-
product
250 Watt Electronic Load Module
N3303A
The Keysight N3303A is a 250 W (0-10A, 0-240V) electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3303A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3303A can also digitize waveforms.
-
product
350W Bench Electronic Load, Single Input 150V, 60A, 350W
EL34143A
Keysight’s EL30000 Series bench electronic loads consist of three models, all with a built-in data logger. The EL33133A basic performance electronic load offers an economical price, a limited range, and a single 40 A, 150 V, and 250 W input. Two performance models offer additional ranges, the EL34143A single input 60 A, 150 V, 350 W, and EL34243A dual input 60A, 150V, 600 W.
-
product
250 Watt Electronic Load Module
N3307A
The Keysight N3307A is a 250 W (0-30A, 0-150V) electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3307A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3307A can also digitize waveforms.
-
product
600 Watt Electronic Load Module
N3306A
The Keysight N3306A is a 600 W (0-120A, 0-60V) electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3306A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3306A can also digitize waveforms.
-
product
PXIe-4051 - PXIe, 1-Channel, 60 V, 40 A PXI Electronic Load Module
788179-01
The PXIe-4051 provides programmable load capable of sinking DC power for characterization, design validation, and manufacturing test. This module helps you sink current and absorb power out of a power source up to 300 W with programmable constant voltage, current, resistance, and power levels. You can use the PXIe-4051 to streamline the task of designing automated test systems for a wide range of applications—from aerospace and defense to automotive and semiconductor component test—by eliminating the need to mix multiple instrumentation form factors in a given test system and simplifying synchronization.
-
product
DC Load Banks
Guangdong EMAX Electrical Co., Ltd.
DC load banks for all voltage levels and power test applications, available in a variety of models including portable and fixed models.
-
product
DC Load Banks
Power House Manufacturing, Inc.
DC load banks by Power House Manufacturing are offered in any voltage from 6 to 1,000 Volts DC.
-
product
DC Load Bank
K-900
Kongter Test & Measurement Co., Limited
K-900 series are your best choice DC load bank with Kongter’s updated solutions. This new series resistive dummy load includes a series customized load bank models that feature rugged design and and excellent performance. They facilitate your work for DC load and battery capacity testing. With different models of DC load bank, it covers a wide range from 12V to 480V nominal voltages with current up to 600A. Its big TFT touch screen with vivid display makes it more user-friendly for setting and operation. Kongter’s new PC software make it easy for measurement monitoring and report print out.
-
product
Load Banks
Power House Manufacturing, Inc.
Load banks manufactured by Power House are engineered to be smaller and lighter than the competition.
-
product
Load Bank
Being the reckoned names in the industry, we offer world-class range of Load Bank that is manufactured with perfection. We offer in different configurations such as Resistive, Inductive, and Capacitive. Our entire product range has high compressive strength and ensures smooth operations. They are durable in nature and are delivered in stipulated time frame.
-
product
Custom Load Banks
Power House Manufacturing, Inc.
Custom Load Banks are our specialty. Power House Manufacturing is dedicated to providing our customers with exactly what they need. Having years of custom load bank manufacturing experience, Power House can deliver the perfect custom testing solution you require.
-
product
Rack Mounted Load Banks
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.
-
product
Programmable AC Electronic Load
63800
Chroma Systems Solutions, Inc.
The Chroma 63800 Loads can simulate load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This special feature provides real world simulation capability and prevents overstressing resulting in reliable and unbiased test results.
-
product
Outdoor Permanent Mounted Load Bank
Mosebach Manufacturing Company
Mosebach Pad Mounted Load bank is designed to be permanently mounted next to a generator for dedicated testing. Its unique design allows it to be one of the smallest on the market! This size enclosure will fit 50 kW, 75 kW or 100kW of testing ability. Also available in 300kW and larger load banks.
-
product
Load Bank
RLB
RARA manufactures load banks, ranging from small portable units for testing generators to multi-megawatt designs for larger applications. Regular load testing, along with correct battery maintenance, is the best way of ensuring the reliability of standby power systems. It is routine for all newly-installed generating sets to have a load test during the commissioning process in order to prove the performance of the set and all ancillaries-cooling system, exhaust system, switchgear and protection schemes.
-
product
AC Electronic Load
AC&DC Electronic Loads are design for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources and other power devices such as switches, circuit breakers, fuses and connectors.
-
product
AC & DC Electronic Load
3270 Series (350V,1875W~22500W)
3270 Series is suitable for the step, square and sine wave of the AC Power device test, especially for the uninterruptible power supply UPS, Inverter, fuses, circuit breakers, power regulator AVR, battery, AC / DC power supply / components ... and so on, absolutely is the best test solution in the market.
-
product
DC Load Banks
Custom DC Units
Mosebach Manufacturing Company
Mosebach has been building DC load banks for over 30 years. We have a wide range of custom-designed units. Please give us a call at 1-866-629-4328 to discuss your needs.
-
product
Resistive Load Banks
R Series
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.
-
product
Dc Load Bank
Highly reliable and durable new alloy resistor is used for the JUNXY DC load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable.
-
product
SMART Constant Current DC Load Banks
SLB-Series
SMART Constant Current DC Load Banks are designed for acceptance testing, discharge testing, battery capacity testing, battery maintenance, engineering examination and other testing for DC power with load. The SMART technology allows a constant current discharge without the need for manual adjustment of current during the discharge test. Our SLB-Series load banks are portable, durable, economic, safe, easy-to-use and come complete with our DataView software, providing the user with a complete data management and analysis program.
-
product
AC & DC Electronic Loads
The Adaptive Power Systems Electronic Loads cover a wide range of power levels, voltage and current profiles and feature sets.Supported voltages range up to 1250Vdc or 350Vrms AC. From bench to system and DC or AC requirements, we can more than likely offer you the optimal programmable load to meet your needs.
-
product
Load Board
cPCI 6U
Load boards are essential in keeping any system in top running shape. As a full-system provider, Hartmann strives to not only provide the systems you need, but the supporting hardware as well.
-
product
AC Electronic Load
The electronic AC loads cover a wide variety of different voltage, current and power ranges. All the AC loads are programmed with 11 different sine, square and DC waves. With 5 crest factor variations of each, a total of 55 waveforms are available. An external input is also provided to enable the user to amplify signals from a waveform generator.AC Loads allow real world operating conditions to be simulated. Typical applications include circuit breaker, transformer & UPS output testing along with general laboratory and research work.
-
product
Inductive Load Banks
L-Series
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
product
AC and DC Electronic load
63800 series
The Chroma 63800 Loads can simulate load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This special feature provides real world simulation capability and prevents overstressing thereby giving reliable and unbiased test results. The 63800's state of the art design uses DSP technology to simulate non-linear rectified loads with its unique RLC operation mode. This mode improves stability by detecting the impedance of the UUT and dynamically adjusting the load's control bandwidth to ensure system stability. Comprehensive measurements allow users to monitor the output performance of the UUT. Additionally, voltage & current signals can be routed to an oscilloscope through analog outputs. The instrument's GPIB/RS232 interface options provide remote control & monitor for system integration. Built-in digital outputs may also be used to control external relays for short circuit (crowbar) testing.