Reference Transformers
See Also: References, Reference Standards, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
product
Fourier Transform Infrared Spectrophotometer
IRTracer-100
This system achieves excellent sensitivity with an SN ratio of 60,000:1, high resolution at 0.25 cm-1, and high-speed scanning capable of 20 spectra/second. The performance of medium and higher end models is supported by high reliability including advanced dynamic alignment and an interferometer with a dehumidifier. This is compatible with applications active in a variety of circumstances, with a library of approximately 12,000 spectra and data analysis programs for contaminant analysis, and time course and rapid scan programs for reaction tracking.
-
product
Integrated Transformer Test Van
XD90
Hangzhou Xihu Electronic Institute
The XD90 integrated modular power system testing vehicle provides an integrated yet flexible solution of preforming a wide selection of normal and specialty tests on power equipment. Designed with the effectiveness and efficiency of power testing in mind, this platform achieves the goal of “integration of functions” instead of just a “combination of instruments”. Not only it provides an abundant means of power testing, but with optimized device placement, operational convenience, and safety factor.
-
product
Clamp-On / Precision / Split Core Current Transformer
Transformer Ratio (Arms) : 100A / 1AColours : Red, yellow, blueConnection : Safety Sockets for Banana Plugs ф 4mm Jaw Opening : Cable Dia 15mm max.
-
product
Portable Reference Generator - 5VA
RG-5
Programmable Frequency & Voltage Portable Sine Wave Generator Sunlight Readlable Display Transformer Isolated Output 360 - 11000 Hz with 1Hz Resolution 1.9V to 125V Output with AGC
-
product
Transformer Winding Resistance Testers / TRT ? 2
TRT-2
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fast measurement: Test current 0.02A to 2A DC, Digital display of resistance and test current.
-
product
Reference Cells
Reference cell is used for measuring and setting the intensity of solar simulators for one sun (or other user desired) intensity condition. They are also used to calibrate the IV Measurement system photo-detector intensity to match the measured ISC to calibrated ISC.
-
product
Test Sets For Transformer Industries
Contemporary Test Sets For Transformer Industries are developed to recognize the potentially disastrous current transformer errors. They prevent the primary current from overpowering insulation and short circuits. They are used for developing a testing and maintenance plan for addressing the errors before any failure to save money and time. With these powerful test sets, they are sure to perform saturation testing to test the knee point of a signal by comparing primary and secondary windings.
-
product
FPGA Fast Fourier Transformation (FFT)
eXpert / Fast Fourier Transformation
Fourier Transform Analysis is Advanced On-board FPGA Technology a powerful signal-processing technique used in a wide variety of applications. GaGe’s eXpert FFT firmware allows CompuScopehardware to perform Fourier Analysis within its on-board processing FPGA.
-
product
Solar Reference Cell
The Solar Reference Cells consist of a 20 mm x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 mm x 70 mm x 16 mm metal enclosure with a protective quartz window and a temperature sensor. Designed for calibrating the irradiance of solar simulators used for testing solar cells and modules.
-
product
Transforming Analog Circuit Breaker Testers
MAC-21
The MAC-21 uses proven microprocessor and A/D converter technology to provide real-time waveform analysis. This ensures accurate true-RMS readings of current pulses, even with DC offset and distortion, which are typical in primary injection testing. Intelligent threshold algorithms provide accurate trip time measurement. Integration of measurement and control functions allow advanced features such as preset on times, auto ranging, and optional printer or computer interface.
-
product
Reference Thermometers
Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
product
Auxiliary Current Transformers
Osborne Auxiliary Current Transformers are often used to reduce system currents to lower values appropriate for instrumentation and/or protection circuits. The Aux CT’s are designed for specific current ratios and burden impedance with a known transformation error. Osborne’s units are built for high performance and longevity in the most demanding environments.
-
product
Multiple Gas Transformer DGA
MINITRANS
Based on the same core technology as the highly successful TRANSFIX the MINITRANS is a lower cost alternative, monitoring three key gases: Hydrogen, Acetylene and Carbon Monoxide (in ppm) plus moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect a wide range of developing faults including arcing.
-
product
Test Set For Instrument Transformer
This modern Test Set For Instrument Transformer is used for measuring relative errors of Instrument Voltage and Current Transformers. This is developed for reading out the unbalance of any bridge circuit. It also calculates the burden associated to the test sample. In addition to this, it further converts it to ratio and phase error values for presenting them on a LCD screen. With high-tech microprocessor controller, it ensures to provide quick and correct measurements.
-
product
Zero Phase Current Transformer
MZL-30
MULTI MEASURING INSTRUMENTS Co., Ltd.
Split-core type for measuring zero phase current
-
product
HDMI / 3G Reference Media Player
VQS-300
Versatile destop/rackmount unit, loaded with unique sophisticated set of static and dynamic test patterns - see more details in separate VQL for VQS Presentation Multi-format HDMI and 3G-SDI outputs, digital and analog AV outputs 2.5 ppm accurate system clock to meet full 3G-SDI broadcast specs Front side bay for detachable SATA HDD – up to 2 TB of content VQL - Library of unique sophisticated dynamic test patterns and sequences LIve clips and 3D Video Tests, 5.1 Surround Sound and LR Stereo Audio Tests All commonly used resolutions, aspect ratios, frame rates and interlace modes Easy expansion with any external USB storage device: BD/DVD, HDD, FD.
-
product
High Impedance Transformers
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
product
Fully Automatic Transformer Oil Test Set
OTS-A series
The Motwane Manufacturing Company
OTS-A series is fully automatic microprocessor based transformer oil test set designed with advanced features to measure breakdown voltage of insulation oil accurately. The OTS-A Series preprogrammed with worldwide acceptable standards.The user can define customized standards. The large LCD display with menbrane key pad for easy operation. It is provided with internal memory for 100 data storage & built-in thermal printer for onsite report. The kit is protected by automatic detection of poor input ground.The acrylic oil test vessel provided with adjustable electrode gap setting. The voltage calibrator for on site calibration saves cost & time of user.
-
product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
product
Phase Shifting Transformer
Supreme Instrument Laboratories
Supreme make PHASE SHIFTING TRANSFORMERS are special transformers which provide convenient means to adjust phase angle (power factor) of A.C. loading circuit while testing power factor sensitive device for the full 90 degree LAG through '0' degree to 90 degree LEAD. Based on their rating these Phase shifters are manufactured in two configuration.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
Transformer Turn Ratio Instrument
ART-3D
The ART-3D is high precision instrument designed to measure ratios, magnetization currents, phase-shifting in power transformers, distribution transformers, potential and current transformers, in conformity to IEEE C57.12.90 and CEI/IEC 60076.
-
product
Portable Three Phase Transformer
Supreme Instrument Laboratories
Portable 3 phase double wound transformers both step-up & step-down, natural air cooled construction, housed in well ventilated sheet steel cabinet duly powder coated. All the input and output terminals are brought out and terminated on highly insulated bakelite panels duly marked for easy connection. Necessary carrying handles and castor wheel will be provided for portability.
-
product
Multiple Gas Transformer DGA
MULTITRANS
The MULTITRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor a bank of three single-phase transformers in close proximity. Based on the same core technology as the highly successful TRANSFIX the MULTITRANS measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm).
-
product
Heading Reference Directional Gyroscopes
4000HR-series
The 4000HR air-driven directional gyro offers some of the best features of our other popular models. It inherited all of the functionality and reliability of the industry standard 4000B upon which it’s based, and it picked up a heading reference bug from the 4000C autopilot model.
-
product
Ultra-Low Noise, Precision Voltage Reference
ISL21090
The ISL21090 is an ultra-low noise, high DC accuracy precision voltage reference with a wide input voltage range. The ISL21090 uses Renesas' advanced bipolar technology to achieve sub 1.0µVP-P (1.25V option) 0.1Hz to 10Hz noise with an initial voltage accuracy of 0.02% (2.5V option).
-
product
Split type AC Current Transformer
CTF-100T
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Wire stopper is equipped for the slipping protection.*The special connector is not necessary as the output terminals are provided.*Open circuit protection and nonflammable plastic material.
-
product
3207a GPS/GNS Frequency and Time Reference
GlobalTyme2
Precise Time and Frequency, Inc.
The ptf 3207A GlobalTyme2 GNS Receiver introduces a new level of advanced capability from a second generation, based on the highly successful ptf 3203A and ptf 3204A GlobalTyme receivers.The unit is both a frequency standard and a time standard and has been used as a precision frequency reference with low phase noise, in satellite communications applications around the world.
-
product
Reference Coordinate Measuring Machine
XENOS
XENOS from ZEISS features two linear drives in the Y direction, which are synchronized via a new technology developed by ZEISS: the central drive. It ensures optimal force distribution of the drives depending on the position of the X axis.
-
product
Transformer Testing
Haomai Electric Power Automation Co.,Ltd.
1)Test Standard:IEC60076 & IEEE C57.12.90 2)Voltage ratio measurement of transformer 3)Turns ratio measurement of transformer 4)Group vector measurement of transformer





























