Frequency Calibrators
-
Product
Scientifically Calibrated Audio Clips
AudioRef™
-
AudioRef is a package of scientifically calibrated audio reference clips that enable professionals to accurately set up and evaluate audio monitoring equipment.
-
Product
OTDR Training & Calibration Solution
-
In addition to network simulation applications, the Fiber Lab 800HE from M2 Optics is a professional optical fiber platform that enables technicians to practice using an OTDR to find splices, faults, or bad connections in a length of optical fiber. In addition to training, it can also be used by equipment servicing teams to calibrate OTDRs with fiber that includes pre-determined events at known points.
-
Product
Microphone Calibration Workstation
9350C
-
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
Product
Pressure Test & Calibration Pumps
-
Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 1,500psi (100bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 918 is an ideal comparison test pump for pressure instruments calibration.
-
Product
1KVA Variable Frequency Power Source
CX- 9001
-
Shenzhen Chuangxin Instruments Co., Ltd.
1KVA Variable-Frequency Power Source
-
Product
Measuring and Calibration Stations
PCB
-
Is used to measure electric and magnetic fields of an ESD generator
-
Product
UV/VIS/NIR Spectrophotometer Calibration Standards
-
As the world's foremost spectrophotometer reference standard manufacturer, we have a dedicated staff and years of experience to back up our products. Our solid state UV/VIS/NIR reference standards are the most stable on the market and remain in spec long after many other manufacturer's standards go bad. Relying on our proprietary nano-deposition technology, you can rest assured that our solid-state standards will produce steady readings for years to come on your machines.
-
Product
Test gas - for calibration
-
Test gases for gas measuring and gas warning devices.Enables the functional control and calibration of measurement technology.
-
Product
Calibration Substrates
-
The GGB Industries, Inc., line of CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe® at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected
-
Product
Dynamic Calibration for ROSS Streak Cameras
DynaCal
-
The DynaCal Optical Calibration Module (OCM) is designed exclusively for the Sydor ROSS Streak Camera to ensure accuracy, both over time and in situ, so you can be confident that the data from your shot is certified to be correlated to the calibration of your camera. The beauty of in situ calibration is that the cost of removing and resetting the camera is avoided—and so is the risk of the replacement of the camera and shifting or disturbing the sensitive nature of streak camera results. Only in situ calibration will reveal the real world effects of EMR, gravity, electronic noise and more when they distort your camera results.
-
Product
Frequency Response Analyser
DP-cPCI-7554
-
DP-cPCI-7554 is a cPCI module capable of analyzing the phase and gain characteristics of a system. The system under test is stimulated by the user defined waveform. The obtained response is correlated with the applied stimulus by the on-board DSP processor to determine the phase difference and the gain.Gain and the face analysis is carried out only at sine waveform.
-
Product
350 MHz Universal Frequency Counter/Timer, 12 digits/s, 20 ps
53230A
Frequency Counter
The Keysight 53230A universal frequency counter/timer serves all your frequency and time interval measurement needs. In addition to the typical frequency and time interval measurements, continuous/gap-free measurements are available for basic modulation domain analysis. Optional burst measurement software is available. An optional microwave channel can be added to measure 6 or 15 GHz.
-
Product
Calibrator for Battery Charger-Analyzers
VCM-100
-
The VCM 100 is an instrument designed to verify the performance and to calibrate Battery Charger-Analyzers used on Nickel-Cadmium, Lead-Acid and other types of batteries.
-
Product
Frequency Analyzers
-
The groundbreaking multi function measuring system from RION Compact design, easy and intuitive operation Wireless connections Use it anytime anywhere!
-
Product
Reference Frequency Generator
MFCh
-
*Frequency reproduction accuracy ± 2 x 10 -9 *Output frequency 1 Hz - 10 MHz *Output pulse signal 1 kHz The MFC is designed to generate high-frequency pulse signals with a frequency of 1 kHz and a frequency in the range from 1 Hz to 10 MHz along two output lines. The MFC is designed to operate in measuring systems based on the VXIbus trunk. In the MFC, a rubidium frequency standard is used as a reference frequency source. Time to reach the mode when the power source of the rubidium standard is turned on, no more than 10 min
-
Product
Hydrogen Frequency & Time Standard
CH1-1006
-
The hydrogen frequency and time standard Ch1-1006 is designed to generate highly stable, high-frequency, spectrally pure sinusoidal 5, 10, 100 MHz and pulsed 1 Hz signals and for the behavior of time-frequency measurements.
-
Product
Resonant Frequency Testing
E-Meter MK II™
-
Determines resonant frequencies of the three modes of vibration. Material characteristics such as Youngs Modulus of Elasticity, Modulus of Rigidity, Poissons Ratio and Damping Constant can be calculated. Frequencies are automatically scanned in one of four ranges. The system can determine flexural resonance of concrete under accelerated freezing and thawing cycles and aggressive environments.
-
Product
Rubidium/GPS Frequency Standard
PXIe-3352
-
The Astronics Test Systems PXIe-3352 frequency standard module sets a new standard for high density functionality in a PXI module by combining a Rubidium oscillator with a GPS receiver into a single, compact instrument.
-
Product
Dry Block And Bath Calibrators
-
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
Product
Automatic Calibration Function oH Meter
AH-151
-
The pH meter AH-151 with automatic calibration function performs pH measurement by automatically cleaning the electrode with cleaning solution and performing calibration with standard solution, making it possible to drastically reduce maintenance work. In addition, by spraying the calibration solution, the consumption of calibration solution has been reduced. The spray amount of the cleaning solution can also be adjusted according to the condition of contamination, which contributes to cost reductions. With periodic cleaning and calibration, stable and highly reliable pH measurements are possible.
-
Product
Documenting Calibrators
-
We offer documenting calibrators, for us the “documenting” calibrator means a calibrator that can store the calibration results into its memory and upload them to calibration software. This benefits you as you don’t need to carry pen and paper and spend time in making notes and typing them into software.
-
Product
Thermocouple Calibration Furnace
9118A
-
The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics.
-
Product
Frequency Converter
FC5-29M
-
Frequency converter FC5-29M is a measurement instrument which is designed for spectrum conversion of 75 - 170 GHz to 1 MHz ÷ 2,6 GHz range and automatic frequency measurement of sinusoidal signals. When combined with the 1 MHz - 3,0 GHz spectrum analyzer, FC5-29M can be used for examination of the continuous and periodically repeating pulse signals.The instrument is meant to be used for measurement of various signal sources, radio-transmitting instruments, synthesizers, frequency converters, measurement generators and also for adjustment and verification of various radio-transmitting or communication instruments in laboratory and workshop conditions.
-
Product
Decade Box, Calibrated W/Data, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL D
-
The 72-7265 CAL D from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
RTD Calibrators
-
Practical Instrument Electronics, Inc.
PIE has an RTD calibrator to fit your needs from the PIE 510B single type RTD simulator to the advanced troubleshooting capabilities of the PIE 311Plus. Have you had issues in the past where your RTD calibrator wouldn’t work with some of the instruments in your plant? Our RTD calibrators are guaranteed to be compatible with all process RTD inputs including all brands of smart temperature and multivariable transmitters, PLC input cards, DCS systems and multichannel recorders.
-
Product
DC - 12 GHz Packaged High Efficiency Divide by 8 Prescaler
HMMC-3128-TR1
Frequency Divider
The HMMC-3128-TR1 is a packaged DC - 12 GHz divide by eight prescaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
Product
CALIBRATION LABORATORY
-
Micro Precision Calibration Inc.
Environmentally controlled facilities to ensure high quality and accurate calibrations and measurements.Direction by a Professional Engineer registered in Metrology by the State of California.Professionally trained technicians in electronic and mechanical calibration.Quick turnaround by a full staff -- from sales to service.Full custom database for data sheets, history, invoices, and computerized recall for upcoming due date.Service by all major carriers, with our own pick-up and delivery in some areas.Customers include over 10,000 companies globally.Technical support for ISO, MIL standards, and database set-up.Calibration Labs are located in the USA, Southeast Asia and Middle East.
-
Product
New Line of Frequency Synthesizers (Insight FS) from 36 to 1250 GHz
-
In the millimeter wave range, each synthesizer covers a full waveguide band (Q, U, V, E, W, F, D, G, Y, J). Insight FS provides several options for frequency and amplitude modulation (analog FM/AM modulation, frequency manipulation, pulses modulation). Insight FS are compact in size and controlled by IEEE, analog input, or manually.
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
Redundant Reference Frequency Shaper
CH7-317
-
Redundant reference frequency shaper Ch7-317 is designed to generate and reproduce frequency and time signals protected from frequency and phase failures based on the results of signal processing from a group of frequency and time keepers.





























