Frequency Calibrators
-
Product
2-18GHz Instantaneous Frequency Measurement Unit
DR073
-
Teledyne Defence & Space’s Instantaneous Frequency Measurement (IFM) module, also known as a Digital Frequency Discriminator (DFD), offers high speed frequency measurement across the full operating bandwidth.The IFM measures the frequency of RF signal present at its input and presents a result at its output as digital data. The RF input signal is conditioned by an RF amplifier that provides sufficient drive for the frequency resolving circuits. The raw video from the resolvers is digitised and processed into the required output format. There is additional timing and control circuitry which initiates the measurement process and provides handshake data to the host system processor.
-
Product
Calibration Systems
-
Brüel & Kjær Sound & Vibration A/S
Our calibration solutions meet the broad variety of needs for calibration in the field of sound and vibration accurate primary and secondary calibration of measuring equipment and the scope of transducers: accelerometers, microphones and hydrophones.
-
Product
Probes, Sensors, Measurement Microphones, Calibrators, Accessories
-
Passive Probes, Active Probes, USB Isolators, Noise & Vibration Sensors & Accessories, Electro-Acoustic Test Accessories
-
Product
Magnetic Calibration
-
Trescal provides full Magnetic Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Magnetic Calibration services can be delivered at your site or at our lab. Accreditations for our magnetic calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Time to Amplitude Converters and Calibrator
-
A Time-to-Amplitude Converter (TAC) can achieve exceptional precision by using an analog technique to convert small time intervals to pulse amplitudes. When a timing application demands picosecond precision, a time-to-amplitude converter is a prime candidate. A time-to-amplitude converter is a productive solution for measurements less than 10 μs when time resolutions from 10 ps to 50 ns are required.
-
Product
Process Calibrators
-
4-20mA Process calibrators are specific equipment which, thanks to the employed modern building technology, is now part of the range of mobile devices which have become indispensable to technicians working on modern installations.
-
Product
Radio Frequency Scoring Tool
RFST
-
The Radio Frequency (RF) Scoring Tool (RFST) takes the guess work out of RF environment simulation. During RF environment simulation, the RFST provides clear persistent scoring and recording of the RF simulator’s performance. The RFST digitizes all RF signals in the form of digital Pulse Descriptor Words (PDWs) and associated In-phase/Quadrature (I-Q) data. This massive data stream is recorded for later (Post-Scenario) Analysis. Additionally, the RFST provides a real-time visual display of the accuracy of the RF output, easily visible through straight forward real-time indicators. The post analysis tool set allows an unlimited number of users to simultaneously assess previous RF simulator performance with compelling visual representations. The RFST is a perfect complement to our A2PATS product line offering everything you need for comprehensive environment simulation and analysis.
-
Product
Frequency Offset Measurements
S93080B
-
The S93080B frequency offset capability enables the network analyzers to set the source frequency independently from where the receivers are tuned.
-
Product
Calibrators
-
Is a device used to adjust an instrument accuracy, often associated with a specific application.
-
Product
Transducer Calibration
-
When it comes to finding the perfect transducer calibration system, look no further than MB Dynamics. Our Calibration Systems offer an extensive range, from the Win475-Basic, the trusted calibration solution for the United States Air Force; to the first of its kind Win475-TS, which measures a transducer’s transverse sensitivity. No matter what your needs, you’ll find the calibration equipment that works for you.
-
Product
Aircraft and Truck Scale Calibrator
-
Morehouse Instrument Company Inc.
Aircraft and truck scale calibration often requires special adapters to simulate a tire. Scales come in a variety of sizes and have specific tolerances. Many other calibration laboratories do not use the right adapters or consider the impact of the uncertainty of the reference standard used for calibration.
-
Product
Signal Calibrators
-
Nagman Instruments & Electronics Pvt. Ltd
If you are looking for Signal calibrators that are best in industry, head over to Nagman website immediately. We have a range of signal calibrators, loop calibrators, milliamp calibrators, process meter and more. Depending on the requirement at hand, you can find a signal calibrator that is best suited for your industry. Signal calibrators can be used for calibrating thermocouples, RTD, transmitters, etc. while loop calibrators are used for calibrating controllers, indicators, etc. Nagman’s range of signal calibrators are handy, light weight, portable and durable.
-
Product
Current & Voltage Sources for Calibration of Measuring Systems and Sensors
-
ChenYang Technologies GmbH & Co. KG
*DC/AC Current: 0-60A *DC/AC voltage: 0-1000V frequency 50Hz, 60Hz, 400Hz, 1kHz
-
Product
Calibration and Verification Kits
-
Flann offers a wide range of calibration and verification kits to suit many applications and price points. Compatibility with the vast majority of current and legacy VNAs can be provided. Additionally full customisation of our kits is possible to suit your requirements.
-
Product
NIST Calibration for D600A-AT.
D600A-AT-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Gas Calibrators and Zero Air Generators
-
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
Product
NIST Calibration for D610-A
D610-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Decade Box, Calibrated, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL
-
The 72-7265 CAL from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Double Voltage Double Frequency Generator Setup
DVDF
-
This test setup is generally used to perform induced voltage test on the transformers. This set up consists of the USED motor and generator combination to develop the required voltage and frequency. Both generating unit and the drive motor are mounted on a common metallic frame.
-
Product
Automatic Calibration Module
ACM4520
-
ACM4520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Calibration Solutions
-
Calibration or buffer solution lets you calibrate any pH tester to ensure accuracy. Choose from pH 4, 7 or 10. Calibration solution helps you achieve the accuracy that's critical for measuring pH in wastewater, stormwater and process liquids. Sper Scientific offers both liquid and buffer pouches, which are ideal for field use.
-
Product
Ultra High Frequency Vibrometer
UHF-120
-
Polytec?s New UHF-120 Vibrometer Laser-Doppler Vibrometers (LDV) can characterize the out-of-plane vibrations at ultra-high frequencies. Polytec?s UHF-120 extends the vibration frequency bandwidthup to 600 MHz.
-
Product
Waterproof Infra-Red Turbidimeter (NTU) with calibration kit
TN 100
-
The microprocessor-based waterproof TN100 meter is an easy-to-use turbidimeter that meets the rigor of rugged field applications. It is a "must -have" for anyone monitoring turbidity on the go. Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).
-
Product
Calibration Blocks
-
Are used to assess and refine measurement equipment's correctness, and these calibration blocks come in various sizes and shapes.
-
Product
0.5-2.4GHz Instantaneous Frequency Measurement Unit
DR063-M2
-
Teledyne Defence & Space’s Instantaneous Frequency Measurement (IFM) module, also known as a Digital Frequency Discriminator (DFD), offers high speed frequency measurement across the full operating bandwidth.The IFM measures the frequency of RF signal present at its input and presents a result at its output as digital data. The RF input signal is conditioned by an RF amplifier that provides sufficient drive for the frequency resolving circuits. The raw video from the resolvers is digitised and processed into the required output format. There is additional timing and control circuitry which initiates the measurement process and provides handshake data to the host system processor.