Frequency Calibrators
-
Product
Low Frequency 2-Way Power Dividers To 3000 MHz
-
Power dividers from 4 kHz to 3 GHz are available from Pulsar Microwave in connectorized packages with SMA-female connectors, standard. This series is designed to handle 1 watt input power. They are designed for use in 50-ohm systems, and cover frequencies for VHF, UHF, Cell and PCS applications.
-
Product
Dynamic Frequency Selection
-
MET is a leader in performing DFS testing on a variety of WLAN products for FCC, ISED, EU and Japan requirements.Many countries require wireless devices operating in unlicensed 5 GHz bands to have the capability to detect interference with other technology sharing the spectrum (such as military and weather radar systems) and automatically switch over to another frequency.
-
Product
Ultra-Low Frequency Raman Spectrometer Down to 10 cm-1
Modular TeraHertz Raman Spectrometer
-
HORIBA’s modular terahertz modular Raman spectrometer extends the spectral range of a measurement to < 10 cm-1. Consisting of an Ondax SureBlock™ module fiber coupled to HORIBA’s iHR320 imaging spectrometer, this custom system provides an affordable option for macro-Raman measurements close to the laser line. Below are Stokes and anti-Stokes spectra of elemental sulfur recorded with this system.
-
Product
Calibration Services
-
WTG's calibration package is more than just verification of performance specs. It is a complete package of services including inspection and maintenance. Our services uphold the value of the instrument and extend its lifetime.
-
Product
Crossover Calibrator
CC-1
-
The purpose of this tool is to enable the installer to set the crossover frequency of an electronic crossover to the desired frequency, accurately and quickly. It can also be useful for matching gains on multiple amplifier competition type systems.
-
Product
Humidity and Temperature Calibration
-
The most comprehensive temperature, humidity and dew-point calibration offering on the market today.
-
Product
NIST Calibration for D410-A
D410-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
PD Calibrator
-
PDCAL has excellent pulse-with stability; scale calibration factors are permanently stored inside its flash memory. Thanks to on board photo coupler PDCAL output pulse can be synchronized with the actual line frequency through external surrounding electrical light source systems.
-
Product
Documenting Calibrators
-
We offer documenting calibrators, for us the “documenting” calibrator means a calibrator that can store the calibration results into its memory and upload them to calibration software. This benefits you as you don’t need to carry pen and paper and spend time in making notes and typing them into software.
-
Product
DOUBLE FREQUENCY DOUBLE VOLTAGE TEST SET
-
International Biological Laboratories
This test set provides a continuously variable output voltage at double frequency to test the insulation between turns of coils, layer to layer, terminals of windings with either uniform or graded insulation and also between the windings and earth, with graded insulation of both Distribution and Power transformers.
-
Product
Backflow Test Kit Repair Calibration & Certification
-
Meeting Water Safety regulations and standards has become a primary concern for all industries. Most municipal and state regulators demand that Backflow Prevention Testing be carried out no less than once per year and that testing devices be calibrated and if required, certified regularly.
-
Product
Network Analyzer N-Port Calibrated Measurements
S95551B
Network Analyzer
PXI vector network analyzers (VNA) offer the capability to extend the number of ports for your measurements by using additional modules. When multiple modules are used, they are configured for multiport operation. The S95551B adds a multiport analyzer mode that enables full multiport error correction and measurement capabilities. The instruments may be identified as one VNA by the firmware running on an external host PC. At least one VNA instrument connected to your PC must have one S95551B license to maintain N-port capabilities.
-
Product
Audio Frequency Transmitter
TG 20/50
-
Cable fault location with the BAUR TG 20/50. The TG 20/50 is a portable, battery-operated audio generator with a built-in charging unit. Together with the UL audio frequency receiver and the SP detecting rod, the TG 20/50 is used for cable tracing, twist method and for determining the depth of cables and metal pipes.* Automatic or manual impedance adjustment* Charging unit and rechargeable battery integrated; battery or mains operation* Continuous or cyclical output* Two output frequencies selectable
-
Product
Airborne Frequency Converter
AFC Series
-
Behlman’s AFC-7000-1 & -2 and AFC-7003, frequency converter are designed to convert three-phase aircraft power to regulated single-phase (115 or 230 VAC) or three-phase (115/200 VAC) at 50 Hz, 60 Hz or 400 Hz. They are ruggedly built to support aircraft takeoffs and landings and designed to meet the input power requirements of MIL-STD-704 and RTCA-DO-160.
-
Product
NIST Calibration for D620-A
D620-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Electrical Test Calibrators
-
The electrical test calibrators from Time Electronics are designed for rapid calibration of various electrical test equipment. Portable calibrators include the InsCal models for insulation tester calibration and the PatCal for calibration of portable appliance testers.
-
Product
Test & Calibration
-
Gamma Scientific is ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0). In addition to assurance of measurement accuracy, accreditation ensures traceability to known standards, provides international acceptance of measured values, and is important for compliance purposes for your own ISO/IEC certifications. Our state-of-the-art, ISO 17025 accredited calibration laboratories in San Diego, California offer a range of test and calibration services including:
-
Product
WAVEPULSER-40IX + WAVEPULSER-SI-STUDIO-NRZ + Adaptors and Calibration Kit
WAVEPULSER-40iX-BUNDLE
-
High-speed Interconnect Analyzer, 4-port, S-par @40 GHz, <1 mm Res., 4 phase matched cables, bundle.
-
Product
Automatic Calibration Module
ACM4520
-
ACM4520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Calibrator, Calibrated w/D & U, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL DU
-
The 72-6694 CAL DU from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Automated Probe Calibration
AutoClock
-
Metrology Software Products Ltd
AutoClock is the first product in history which makes it possible to fully automate the probe calibration process. It provides fast, accurate and automated tool axis setting. It takes seconds to automatically set the tool axis offset to microns. This enables the probe to complete the automatic calibration process without human intervention.
-
Product
Amplifier for the Frequency Range from 2 Hz to 50,000 Hz.s
Trig-Tek™ 203M
Amplifier
Versatile amplifier covers the frequency range from 2 Hz to 50,000 Hz.s and provides has three simultaneous outputs
-
Product
High-Performance Multifunction Calibrator
5730A
-
The new 50 MHz wideband option for the 5730A High-Performance Multifunction Calibrator provides expanded wideband capabilities to self-maintaining laboratories by providing a method to calibrate the 50 MHz input of the 5790B AC Meaasurement Standard. This is accomplished by characterizing the 5730A's 50 MHz output using a precision thermal voltage converter (TVC), thus reducing uncertainties to calibrate the 5790B.
-
Product
Class 1 Sound Level Calibrator
HD2020
-
The HD2020 sound level calibrator is a portable, battery operated sound source, suitable for sound level meters (portable and laboratory) and acoustic stations.
-
Product
Calibration and Test Equipment Management
-
Is every value precise? The comparability of measurement results has never been more important than in the present era of globalization. The ability to reduce variables to basic units is the fundamental prerequisite to objectively guarantee, increase, and optimize quality. Our calibration service guarantees full correlation to national standards for test equipment of all physical variables – either at our laboratory or on your premises (for measuring tools).
-
Product
8-Channel, 100 MHz Counter/Timer/Frequency Meter Function Card
ProDAQ 3808
-
The ProDAQ 3808 function card, an enhanced version of the ProDAQ 3806 counter/timer function card, is designed to operate in one of three modes: pulse counter, frequency meter, or time interval counter. In the pulse counter and frequency measurement modes, users can process incoming signals of up to 25 MHz on each of the six channels. A time interval counter range is divided into six sub-ranges, covering times from 40 ns to 20000 s with a maximum resolution of 10 ns. For pulse-width measurements, the same ranges apply.
-
Product
Time & Frequency System
TM-4M
-
The TM-4M Time & Frequency System features a larger, easier to use form-factor. It was designed for mobile applications that require uninterruptible power, and for applications that require multiple front panel connections. The six BNC jacks on the front panel are user-assignable to output any signal the user chooses.
-
Product
3207a GPS/GNS Frequency and Time Reference
GlobalTyme2
-
Precise Time and Frequency, Inc.
The ptf 3207A GlobalTyme2 GNS Receiver introduces a new level of advanced capability from a second generation, based on the highly successful ptf 3203A and ptf 3204A GlobalTyme receivers.The unit is both a frequency standard and a time standard and has been used as a precision frequency reference with low phase noise, in satellite communications applications around the world.