UL
-
Product
Wide Angle Scale Instrument
LS-110 LS-80 PF
-
Standard Electric Works Co., Ltd
● Easy to read long-scale and pointer-indications can easily be read from a distance.● Full Scale Deflection : 250°● Accuracy : Class 1.5● Scale Length : LS-110 : 183mm LS-80 : 140mm● Case and Composition : Acrylic resin cover, plastic with UL body and terminal, Four studs mounting. LS-110 case : plastic body option 1 : plastic body with metal case, no UL option 2 : metal case, no UL exception : W, VAR, PF (3P4W)● Color : White scale plate, black terminal plate, black meter body.● Pointer : Sword-type in black color.● TAUT BAND / Pivot & Jewel for LS-110.
-
Product
Lightening Protection
Copper Grounding
-
LBA offers a complete selection of copper bare wire and strap of various widths and gauges for grounding system construction. Our offerings include prefabricated copper ground wire terminations, Copperweld™ ground rods, chemical ground rods, earthing mesh, and exothermic welding materials, as well as UL and NFPA compliant lightning system cable and accessories.
-
Product
High Power Contact
-
Rated to 10,000 cycles.Rated up to 150 Amps with max resistance of 0.35 mOhms.Designed for use with 2 AWG CW6044-14(UL rated) , AS 105-14(Non-UL) or equiv.
-
Product
FCC/CE Certification Testing
-
FCC/CE Certification Testing services to ensure that our product designs meets the necessary FCC/CE/UL norms. FCC compliance testing is mandatory for a wide variety of products designed for the EU/US markets.
-
Product
Usability Testing
-
Underwriters Laboratories Inc.
Ascertaining the safety of medical devices obviously includes the human factor – the people who are using the device must be able to do so safely and effectively. UL''''s usability testing services are aimed at achieving compliance with regulatory requirements, reducing medical device use error, helping manufacturers create user-friendly devices, and reducing training costs.
-
Product
1U Type Power Supply; ATX 270 W
PS270-1U
-
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 18A (0.5A min)**+3.3V, 16A (0.5A min)**+12V1, 16A (1A min)**+12V2, 10A (1A min)**-12V, 0.8A**+5Vsb, 2.5A*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CSA 22.2 NO.60950-1, IEC, UL, NEMKO, CE*Dimensions: 150 x 81.5 x 40.5 mm*Compatible with Axiomtek products: AX61120 / AX60530
-
Product
Fire & Flammability Test
-
Fire & Flammability testing: ASTM E119 [UL 263]; ASTM E152 [UL 10C]; ASTM E814 [UL 1479]; API 607, 6A; ASTM E108 [UL 790]; UL 1709; UL 1715; UL 2043; NFPA 286; UBC 26-2; UBC 26-3; ASTM E84 [NFPA 255, UL 723]; ASTM E162; ASTM E662 [NFPA 258]; ASTM D635; ASTM D1929; ASTM D2863; ASTM E1354; ASTM E1317; Room Burn Facility; CAL 133, 117, 129; UL 94 V/HB; IMO A.652 (16); IMO A.653 (16); ULVW I; ASTM D2859; AITM 2.0007; NFPA 701; FMVSS 302; FAA 25.853; IEEE 383
-
Product
Clamp Meters
-
Clamp meter is a rugged high end AC clamp meter. With a UL listed safety rating of CAT IV 600V / CAT III 1000V, this clamp meter is built to get the tough jobs done.
-
Product
AC/DC Leakage Current Tester
228
-
Test for dangerous leakage current with the Simpson Model 228, designed to meet the latest UL, IEC, and ANSI specifications. The 228 detects both AC and DC leakage current and simulates human response at three different levels -- reaction, let-go, and burn hazard. Each Model 228 comes with test leads with alligator clips, manual, and batteries.
-
Product
Test Finger Nail Probe
CX-75
-
Shenzhen Chuangxin Instruments Co., Ltd.
The Finger Nail Probe is indicated test IEC60335 and UL requirements. Used to check the security of parts that snap together. The spring gauge assembled in the handle can be calibrated to the neccessary force for using the instrument. This probe is make of stainless steel with appropriated hardened tip and a handle in insulating material. Handle has a special adaptor M5 for use with 50N force gauges.
-
Product
Smoke Detection Sensor - UL Approved, TAA Compliant
ENVIROMUX-SDS-TAA
-
For warning of smoke. Photoelectric smoke detector. Built-in 135° F (57° C) thermal heat sensor. Includes mounting hardware. Connect to RJ45 or digital input sensor ports. Supports CAT5/5e/6 UTP or STP cables. Voltage Supply: 8-35VDC. Current Consumption: 200uA. Alarm Output: Relay (NO). Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL. TAA compliant.
-
Product
Electrical Safety Tester
-
Basic testing methods of Glow wire device> and UL 746A, IEC829, DIN695, VDE0471, the Glow wire tester ZRS-3H/ZRS-3HS is suitable for resistance to abnormal heat and fire test on lighting lamps, electronic products and household appliances. Adopting high-temperature coating spraying on steel structure and imported instrument display, with easy operation, stable performance the equipment is applicable to flame resistance tests of all levels of QC departments and corresponding enterprises.
-
Product
AC Contactors
-
Panasonic Industrial Devices Sales Company of America
Panasonic’s line up of AC Contactors includes the HE-N, HE PV, and HE-S Series. Differentiating features and benefits of Panasonic AC Contactors include:*High-Voltage, High-Current Control*Compact Size*High Contact Reliability*Can Be Mounted In Any Direction*RoHS Compliant*UL/C-UL Standard Certified
-
Product
Wide Angle Scale Instrument
LS-110 LS-80 Hz
-
Standard Electric Works Co., Ltd
● Easy to read long-scale and pointer-indications can easily be read from a distance.● Full Scale Deflection : 250°● Accuracy : Class 1.5● Scale Length : LS-110 : 183mm LS-80 : 140mm● Case and Composition : Acrylic resin cover, plastic with UL body and terminal, Four studs mounting. LS-110 case : plastic body option 1 : plastic body with metal case, no UL option 2 : metal case, no UL exception : W, VAR, PF (3P4W)● Color : White scale plate, black terminal plate, black meter body.● Pointer : Sword-type in black color.● TAUT BAND / Pivot & Jewel for LS-110.
-
Product
Cross Voltage Testers
-
designed to perform the 60 Hz power line cross test/AC power fault tests required in GR 1089 issue 6 table 4.5 surge test 3,4, 4.3,and 6, and for UL 1950 section 6.4 paragraph 3 and 4.. Preset and Adjustable Time Settings Measuring Terminals including Voltage Sense and Current Shunt portals provide a safe location for users to accurately measure test voltages and output current while setting up tests. Calibration of the Mini_PT-600 is designed to be performed with a simple handheld multi-meter and the removable Currents Shunts can be easily sent to a calibration laboratory if required.
-
Product
Hipot & Safety Test
-
Chroma Systems Solutions, Inc.
Electrical safety tests to comply with IEC, UL, TUV, CSA, EN, and other electrical safety requirements.
-
Product
12.5 mm Test Sphere Probe
CX-12.5
-
Shenzhen Chuangxin Instruments Co., Ltd.
The rigid sphere (12.5 mm) from Autostrong is designed and manufactured to perform the test specified in many standards (IEC 60335, IEC 60065, IEC 60745, IEC 61029, IEC 60950) to prove the degree of protection for the first characteristic numerals 2 (IP2X) .Its is designed to meet the requirements of international safety regulatory agencies such as UL, DNV, IMQ, BVSQ, ITS, IRAM , CSA, VDE, DIN , INMETRO.
-
Product
Multicoupler, Rack Mount, 1U, Switchable Dual 2×4/1×8, P, LL/UL/S/C, Programmable Amplitude Balance
LS-16A-R1-24SPLUSC
-
High Performance rack mount 1U x 12” deep switchable Multicouplers are available in multiple IN X OUT configurations, such as 1×8, dual 2×4, 1×4 and 1×6. The LS-16 product line covers 300 MHz to 6000 MHz. High output/output isolation and Ethernet / USB controllable gain adjustments for each channel are available as options.
-
Product
Hipot Testers
V7X Series
-
With color touch LCD & high speed DSP technology, the compact & rugged V7X sets the standard for price/performance ratio. Made in the USA to meet tough UL, CSA, TUV and IEC Hipot requirements – the V7X provides unbeatable speed, accuracy, user safety and reliability.
-
Product
Hazardous Location Syringe Pump
1000HLf
-
The Teledyne ISCO HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.
-
Product
UL Rain Spray Test Device With Nozzle
CX-UL56
-
Shenzhen Chuangxin Instruments Co., Ltd.
UL rain spray test device with nozzle Size:500*800*2000mm((adjustable height 1000~2000mm)Nozzle water column intersection from the ground height 0-1400mm adjustable
-
Product
Electrical Product Safety Testing
-
We specialize in pre-certification evaluation, CE marking self-declaration testing, UL / CSA / TUV certification/verification testing. Other agency witness testing may be arranged upon request. CKC’s, and our partners, are equipped to test to a wide array of products including information technology, audio/video, test and measurement, medical and industrial.
-
Product
Speed Switch
DR1000
-
Features • Works with remote / external pulse frequency output sensor (NPN, PNP, or Mag Pick-up) • DPDT relay output • Under-speed setpoint adjustment from 0.5-5,000 rpm (at 8 PPR) • Terminal blocks for easy wiring • 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options • Rugged explosion proof / NEMA 4X housing • UL Listed Class I, Div I (C, D) Class II, Div I (E, F, G)
-
Product
Pressure Transmitters
-
Explosion-proof pressure transmitter is approved for use in hazardous locations per CSA Standard 30 and UL Standard 1203 for Class 1, Division 1 and Division 2 hazardous locations. Wetted parts are all 316L Stainless Steel (50 up to 10000 PSIG), 17-4PH (15000 & 20000 PSIG) for compatibility with a variety of media. Wetted materials and construction comply with the NACE MR0175 Standard. The KP46 Series explosion-proof pressure transmitter's fitting and sensing diaphragm are machined out of a single piece of material, so there are no welds, seams or O-ring seals, resulting in excellent long-term performance and stability. The case is factory sealed, making this pressure transmitter very rugged with excellent shock and vibration resistance.
-
Product
Diaphragm Operated Dual-Action Pressure Switch
H2
-
Explosion-proof, UL & CSA Listed for Class I, Groups B, C & D and Class II, Groups E, F & G. The H2 is designed for sequencing two different actions as pressure of a liquid or gas increases or decreases. The patented design consists of two concentric pistons operated by a single diaphragm with one pressure chamber.
-
Product
Smoke Detection Sensor – 120VAC Wire-In with Battery Backup
ENVIROMUX-SDS-120V
-
For warning of smoke and invisible fire particles. Ionization smoke detector. Applications from 40°F to 100°F (4°C to 38°C). Front loading battery door. 9V battery backup (included) in case of power failure. One button design for easy testing and HUSH mode activation control. LED indicates four modes of operation: standby condition, alarm condition, alarm memory and hush mode. Hush mode: silences false alarms for 8 minutes, or low battery warning for 13 hours. Voltage supply: 120VAC. Pre-stripped wiring harness with tinned strands. Audio alarm: 85dB at 10ft. Dimensions: 5" diameter x 1.75" depth. Dust cover prevents false alarms. Tamper resist feature. Links with up to 24 devices. Max distance between first and last device: 1000ft (305m). Alarm memory indicates initiating alarm in interconnected systems. Use compatible relay (ENVIROMUX-RLY-SDS120V) for connection to the ENVIROMUX system or other auxiliary warning devices such as external sirens or stairwell lighting. ENVIROMUX-RLY-SDS120V includes normally open and normally closed contacts. Contact ratings: 10A at 120VAC, 5A at 30VDC. Regulatory approvals: UL.
-
Product
5W to 15W - Single Output
KPSA Series
-
*Small size and lightweight*PC board mountable*Low Cost*UL Class II Approved*Wide input range*No external components needed
-
Product
Thermal Abuse Test Chamber
-
Guangdong Bell Experiment Equipment Co.,Ltd
DGBell's Thermal abuse test chamber is suitable for standard IEC 62133-2017, UL 1642 and GB 31241-2014.
-
Product
3.0mm Preset Controls Probe
CX-A3C
-
Shenzhen Chuangxin Instruments Co., Ltd.
Used to verify protection against access to hazardous parts by use of a tool through holes which give access to pre-set controls. Meets IEC, EN, UL and CSA Standards including IEC 1010, EN 61010-1, U- 3101-1, UL 3111-1 and CSA 1010-1. The handle and stop face are made of Delrin®. The rod is stainless steel.
-
Product
UL94 Horizontal & Vertical Flammability Tester
-
TESTEX Testing Equipment Systems Ltd.
UL94 Horizontal & Vertical Flammability Tester, used to determine the flammability of plastic materials for parts in devices and appliances. UL94 Horizontal & Vertical Flammability Tester complies with UL HB, UL94, IEC 60695-11-10, etc. Contact us for UL 94 flammability test procedure.





























