Voltage Loggers
Record voltage measurements.
See Also: Loggers, Pressure Loggers, Current Loggers, Dataloggers, Humidity Loggers, Temperature Humidity Loggers, Temperature Loggers, Wireless Data Loggers, Wireless Loggers, Data Loggers
-
product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
779785-01
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
product
NI-9252, ±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module
786783-01
±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module - The NI-9252 is an 8-channel analog input module for CompactDAQ and CompactRIO systems. Each channel provides a ±10 V measurement range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9252 features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
product
NI-9264, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
780927-02
25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The NI‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the NI‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection.
-
product
AC-Powered, AC Voltage Monitor, Adjustable
VMA
NAI’s VMA is a field-adjustable, AC-Powered, AC Voltage Monitor used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits.High and low voltage limits, and "pick-up" and "drop-out" time delay are field-adjustable. The VMA voltage monitor is ideally suited for rugged defense and industrial applications.
-
product
NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module
785184-01
±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.
-
product
NI-9239 , ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
780181-01
±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.
-
product
Voltage USB data logger
EL-USB-3
This data logger measures and stores up to 32,510 voltage readings over a 0-30V d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista.
-
product
NI-9201, ±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779372-01
±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9201 is an effective combination of channel count and speed at a low price for an economical multifunction system. The module features up to 100 V of overvoltage protection for errant signal connection or unexpected signals to the individual channels.
-
product
DC-Powered, AC Voltage Monitor
VAD/VQD
NAI’s VAD and VQD are DC-Powered, AC Voltage Monitors used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits. These voltage monitors are ideally suited for rugged defense and industrial applications.
-
product
Process Voltage & Current Data Loggers
Monitor and log virtually any process voltage or current output from your transducers.
-
product
Low Level, DC Voltage Data Logger
Volt101A
The Volt101A is one of MadgeTech's newest data loggers. It is part of a new series of low cost, state-of-the-art data logging devices. MadgeTech has taken the lead in offering the most advanced, low cost, battery powered data loggers in the world today.
-
product
Data Loggers
For acquiring temperature, pressure or fill levels, use the highly precise long-time data recording devices of the MSX-ilog series by ADDI-DATA. The compact, portable and interference-free systems are ideal for acquiring data at different locations in your installation. Data is automatically converted to physical values and can be calculated via the onboard µ-processor. The integrated web server allows easy configuration, monitoring and data export. Further features: Onboard data saving, internal clock, low consumption and Ethernet interface, data thus being available on the company network for evaluation and statistical purposes.
-
product
The Field Logger
The Field Logger is a stand-alone data logger which is capable of recording potential vs. time and LPR vs. time data. The instrument is battery powered and records data onto an attached SD memory card. The instrument is entirely contained within a waterproof (IP67), tough polycarbonate enclosure (23x19x11cm), with probe connection via a single high quality watertight Lemo or Amphenol connector.
-
product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779373-01
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
product
Midi Logger
GL240
Its compact size contains an isolated input system which ensures that signals are not corrupted by inputs to other channels, thus eliminating wiring concerns. The GL240s multi-type inputs are suitable for voltage, temperature, humidity, pulse, and logic signals, enabling combined measurements of different phenomena like temperature/humidity and voltage. power ground allowing off-ground measurements using shunts, as well as powered or grounded thermocouples.
-
product
CAN Logger
Reach Technologies' CAN Logger is a high performance, high channel count, DSP enabled, automotive bus data logger. The CAN Logger is ideal for capturing all or specific bus traffic for vehicles under test. The CAN Logger is also perfect for real-time monitoring of specific signals.
-
product
Mini Logger
OBD
The DAWN OBD Mini Logger™ is a compact, low-cost data logger to acquire CAN bus data from cars and trucks. The logger installation is simple since it snaps directly on the J1962 OBD connector. The logger is so small that it fits in the palm of your hand.
-
product
Data Logger
LR8520
• Record fungal index, growth prediction, temperature and humidity • Minimum 0.5 sec interval • Wireless data download to a tablet or computer
-
product
Temperature Logger
TGU-4020
This unit uses an external probe (not included) to record temperature in awkward to reach areas or applications where a fast response is required. It can also measure higher temperatures than the self-contained unit. The tip of the probe can be exposed to temperatures up to 125C.
-
product
NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module
780159-02
300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.
-
product
Data Loggers
The unit can acquire data from on-board interfaces at rates of up to 10 kilosamples per second, and from remote units via communications links. A high-performance on-board PowerPC microprocessor offering over 1000MIPS processing power hosts customer applications for real-time data analysis. Application code may be autocoded using our Graphical Development Environment (GDE) from Matlab/Simulink control modules. Data is logged to 2GB of on-board Flash memory and downloaded for analysis via a Gigabit Ethernet network connection.
-
product
Temperature Logger
SRIL-8
The LogTag® Dry Ice “Probe-less” Temperature Logger operates, measures and stores up to 8000 temperature readings in temperature environments ranging from -80°C to +40°C (-112°F to +104°F).
-
product
Data Logger
MS6R
The complete solution for monitoring of temperature, humidity and other values. For desktop use with rubber feet - see Optional accessories. For mounting to 19" rack - one rack unit 1U.
-
product
Data Logger +
DL-8T
Monitor and record temperature in eight different locations with the Model DL-8T Temperature Logger. The DL-8T has a built-in sensor for local temperature monitoring and accepts seven external thermocouples in types J, K, T, S, or E.
-
product
Data Logger
ETR101A
The ETR101A kit comes assembled and includes a data logger (TC101A-MP), temperature sensor (thermocouple type K), water resistant enclosure, interface cable (IFC200), hex screwdriver and software.
-
product
Communication Data Logger
LE-270GR
LE-270GR is a Communication Data Logger, which has acceleration sensor and a connector for GPS antenna. It has logger mode with which you can records CAN/LIN communication logs in the SD/SDHC card for long hours and remote mode with which you can monitor data or GPS data on the PC at real time by connecting the analyzer with PC. It also has simulation mode with which you can repeatedly transmit CAN/LIN data which is registered in advance and selected on PC. It has galvanic-isolated two CAN transceivers and two LIN transceivers. Thus you can measure 2 channels of CAN/LIN communication lines and can simultaneously register GPS positioning data, acceleration data, and voltage data of 4 external signals.
-
product
Salinity Logger Sensor
NUL-228
This sensor enables measurements of the salt content in a solution in three ranges: %, ppm and mg/L.The sensor is pre-set factory calibrated and immediately ready to use.
-
product
Temperature Logger Sensor
NUL-203
This is one of our most versatile sensors. It can be used in biology to monitor ecological systems, microbiological cultures and to study the effect of temperature on photosynthesis and enzymatic reactions. In chemistry, to study exothermic or endothermic reactions and how the rate of reaction is affected by temperature; in physics it can be used to study heat/energy transfer.
-
product
Loggers
The HiGee/LoGee are ultra-small, ultra-light, 3-axis, battery powered, stand-alone, programmable shock recorders. These low-cost recording devices measure and records the peak acceleration levels to which it is exposed, along with their time of occurrence.





























