Showing results: 91 - 105 of 303 items found.
-
-
MC740 -
Milwaukee Instruments
The Milwaukee MC740 PRO Conductivity (EC) controller and pump lets you measure and adjust EC levels automatically.
-
MC745 -
Milwaukee Instruments
The Milwaukee MC745 PRO Conductivity (EC) controller and pump lets you measure and adjust EC levels automatically.
-
FES-210L -
HORIBA, Ltd.
The FES-210L Series sanitary conductivity sensors are electric sensors that target sanitation issues by employing a flat structure that keeps dirt from adhering to the tip of the sensor, and they enable continuous, high accuracy measurement in liquids of various concentrations, from purified water to cleaning solutions.The FES-210L Series, which is used in conjunction with the conductivity converter HE-960HS, demonstrates the optimum high sanitary characteristics that are ideal for the concentration and CIP management employed at food (beverage) and cosmetics plants.
-
miniCT -
Valeport Ltd,
The miniCT is Valeport’s real time Conductivity and Temperature sensor package. It features high accuracy sensors combined with a robust design to make it suitable for inclusion in a variety of sensor suites, fixed site monitoring in still wells or for use on frames andbuoys, ROVs, AUVs and ASVs
-
INFINITY-CTW ACTW-USB -
JFE Advantech Co., Ltd.
Infinity-CTW is an autonomously deployable data logger for highly accurate temperature and salinity measurements during long-term periods. The instrument has a mechanical wiper that periodically sweeps the sensing surface of the seven-electrode conductivity cell to keep the initial accuracy, avoiding bio-fouling without chemical materials and frequent maintenances. Infinity-CTW allows for accurate and stable salinity measurements for several months without cleaning maintenances. Infinity-CTW performance was evaluated and reported by Alliance for Coastal Technologies, ACT code: VS09-06).
-
TP02 -
Hukseflux Thermal Sensors B.V.
TP02 is a probe that offers the possibility to perform a practical and fast measurement of the thermal conductivity (or thermal resistivity) of the medium in which it is inserted at the highest accuracy level. It works in compliance with the ASTM D 5334-00, D 5930-97 and IEEE 442-1981 standards. The standard TP02 probe has proven suitability in soils, thermal backfill materials, sediments, foodstuff, powders, sludges, paints, glues and various other materials. The Non-Steady-State Probe (NSSP) measurement method (also known as transient line source, thermal needle, hot needle, heat pulse- and hot wire technique) has the fundamental advantages that it is fast and absolute while the sample size is not critical. Hukseflux is specialised in NSSP design. Special models have been developed for in-situ field experiments. For permanent installation in soils, a dedicated model, TP01, is available. TP02 has been designed and tested in collaboration with the Applied Physics Group of Wageningen University.
-
rapidPro CTD -
Valeport Ltd,
Optionally, the rapidPro CTD is designed to operate with the Teledyne OceanScience rapidCAST underway profiling winch to deliver the highest quality CTD and optional optical parameter casts on the move. While the vessel is underway profiles of up to 450m at 6 knots are expected.
-
CyberScan PC 300 -
Thermo Scientific
Waterproof and Dustproof Housing - IP67 rated, ideal for rugged harsh conditions. Plus it floats!
-
SKZ1061A -
SKZ Industrial Co., Ltd
Single material:foam (insulation material surface flat, plate), polyurethanes, phenolic, urea-formaldehyde, mineral wool(glass wool, rock wool, mineral wool), cement wall.Composite materials:glass composite CRC, cement enhanced polyphony board, sandwich concrete, fiber glass panel composite plate, paper cellular plate
-
HE-960CW -
HORIBA, Ltd.
HE-960CW connects conductivity sensor (ESH /FS Series) and measures conductivity and temperature in the sample water. It is ideal for the conductivity control of the purified water, pasteurized water, and water for injection that are used in the production of pharmaceuticals.And we have developed a lineup of electric conductivity sensors that can be used in conjunction, from the conventional insertion type to the flow-through type with improved cleaning and sanitary properties.
-
HE-480C -
HORIBA, Ltd.
HE-480C connects conductivity sensor (ESH /FS Series) and measures conductivity and temperature in the sample water. This is a highly functional model, with high-performance temperature compensation, and is applicable to a wide range of tasks, from managing pure water for use with semiconductors, to managing the quality of boiler water.
-
MTN01 -
Hukseflux Thermal Sensors B.V.
The MTN01 Multi-purpose Thermal Needle System allows performing fast measurements of the thermal resistivity or conductivity of soils. It is specifically designed to be reasonably robust, as well as accurate. It is therefore suitable for laboratory as well as field- measurements of soil thermal properties. The sensor is a Non-Steady-State Probe (NSSP), TP07, which is mounted on the Insertion Tool, IT02. The system is operated using a hand-held Control and Readout Unit CRU01.
-
PN-50α -
NAPSON Corp.
*Principle: Photovoltaic effect by light pulse irradiation*No damage and no stain by Non-contact method*Possible to check even oxidized film on wafer surface*Instantly discrimination by optical pulse illuminate
-
HE-480C-GC -
HORIBA, Ltd.
The length of the sensor has been reduced by 50% as compared to existing systems to reduce space requirements. At the same time, the measurement range has been increased tenfold, enabling the system to measure even samples with comparatively high concentrations. Two different types of chemicalresistant glassy carbon sensors can be used, making the system ideal for chemical dilution/recovery management and pure water recycling as well.