HFC
-
Product
Mass Flow Controller for Medium Flow
HFM-201 / HFC-203
-
The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.
-
Product
High Frequency Current Transformer
HFCT
-
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.
-
Product
Mini Fiber Optic Receiver
MX555 series
-
The Maxcom MX555 series optical receivers are versatile, low-cost and compact optical receivers are versatile, low-cost and compact optical receivers for use in HFC fiber applications.
-
Product
Fast Response Flow Controller for Medium Flow
HFM-305 / HFC-307
-
The HFM-305/HFC-307 is Teledyne Hastings' fast response series of mass flow meters and controllers. Featuring reliability and stability, the 300 Series is chosen for its fast response under a wide range of conditions. .The HFM-305 / HFC-307 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured to have either normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-305 / HFC-307 services a wide variety of applications. Cleaning for oxygen service is available.
-
Product
High Frequency Current Transformer Clamps
HFCT-20HD & HFCT-60HD™
-
The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.
-
Product
Mass Flow Controller for Medium Flow
HFM-201 / HFC-203
-
The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.
-
Product
Mass Flow Controller for Low Flow
HFM-200 / HFC-202
-
The HFM-200/HFC-202 is Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers. Featuring reliability and stability, the 200 Series is chosen by OEM's for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.
-
Product
Other CATV Meters
-
Wuhan Sunma Technology Co., Ltd.
SunmaFiber provide all kinds of CATV meters, such as Signal Level Meter, QAM Analyzer, Spectrum Analyzer, DVB/DVC/DVT Analyzer and other TV testers. also you can find other more equipment in CATV / Broadcasting fileds, such as Three Frequency Points, HFC Return Path Signal Generator, Return Path Signal Generator, Digital RF Signal Generator and so on.
-
Product
Fast Response Flow Controller for Medium Flow
HFM-301 / HFC-303
-
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
Product
Mass Flow Controller for Medium Flow
HFM-205 / HFC-207
-
The HFM-205/HFC-207, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-205 / HFC-207 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a full complement of fitting and elastomer options, the HFM-205/ HFC-207 covers a wide range of high flow applications.
-
Product
Digital "A" Flow Controller for Low Flow
HFM-D-300A / HFC-D-302A
-
HFM-D-300A / HFC-D-302A mass flow instruments have flow ranges from 0-5 sccm to 0-25 slm; use all metal seals, provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
Product
Mass Flow Controller for Medium Flow
HFM-205 / HFC-207
-
The HFM-205/HFC-207, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-205 / HFC-207 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a full complement of fitting and elastomer options, the HFM-205/ HFC-207 covers a wide range of high flow applications.
-
Product
Digital "A" Flow Controller for Medium Flow
HFM-D-301A / HFC-D-303A
-
Mass flow techniques provide reliable, repeatable and accurate gas flow rate measurements.HFM-D-301A/HFC-D-303A mass flow instruments have flow ranges from 0-25 slm to 0-1000 slm; provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available. Available with a variety of elastomer seals for maximum flexibility.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
Product
Fast Response Flow Controller for Medium Flow
HFM-305 / HFC-307
-
The HFM-305/HFC-307 is Teledyne Hastings' fast response series of mass flow meters and controllers. Featuring reliability and stability, the 300 Series is chosen for its fast response under a wide range of conditions.The HFM-305 / HFC-307 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured to have either normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-305 / HFC-307 services a wide variety of applications. Cleaning for oxygen service is available.













