product
Counter Electrodes
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
product
Electrodes
EGL electrodes have consistently raised the industry standards for reliability and performance since their introduction in 1930.To ensure rigid quality control, all phases of manufacturing are performed in-house, including emission coating, inverter welding shells with lead wires, and sealing and centering the mounts in glass envelopes.
-
product
Electrodes
Electrodes are offered in a wide variety of types. Spring electrodes are normally used in the inspection of pipes, although circular brush electrodes can also be used. Flat brush electrodes are used for flat surfaces. Brush materials can be of brass, steel or conductive neoprene construction. Internal electrodes are for testing internal pipe coatings.
-
product
Cells and Electrodes
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
product
Working Electrodes for Flow Cell
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
product
Starter Electrodes
Backed by our commitment to accurate and precise measurement, the OHAUS Starter Series of electrodes are designed to produce exact results time and time again.
-
product
ESD LCD SURFACE RESISTIVITY METER (WITH 1 PAIR OF 5 POUND ELECTRODES)
The ESD LCD SURFACE RESISTIVITY METER provides everything necessary to test work surfaces using the procedure outlined in the EOS/ESD-S4.1 standard. This test kit makes testing surface resistance easy – simply place the weights attach the cables, switch to the correct voltage and press the button to read resistance directly on the meter. The meter incorporates parallel probes on the bottom of the unit which allows the user to make surface resistivity measurements. The parallel probes allow for quick and easy testing of a variety of surfaces and materials, without the use of the five pound electrodes
-
product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
product
Handheld Water Quality Meters
LAQUA DO210
Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation0.01 mg/L or 0.1% DO resolutionCompensates salinity, temperature, and atmospheric pressure Allows up to 2 calibration points using galvanic DO electrode°C & °F temperature readingsAuto log data; built-in memory can store up to 500 dataAuto stable, auto hold, and real-time measurement modesAuto shut-off (programmable: up to 30 minutes)Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mmCasing is IP67 waterproof/dustproof, shock & scratch resistant, non-slipPowered by 2 x AA batteriesPackaged with galvanic electrode in carrying case3 years meter warranty
-
product
Handheld Water Quality Meters
LAQUA WQ-320-K
- Dual channel- Large colour graphic LCD screen (70 x 52 mm) with backlight - Built-in foldable meter stand- IP67 waterproof and dustproof- Battery and USB powered- Eco-friendly, shock-proof, scratch-resistant, and non-slip- Built-in sensor holders- Efficient sensor locking mechanism- Sensor's LED light as reading stability indicator- No sensor adapter needed for attaching multiple sensors together- Compatible with conventional electrodes having BNC and phono connectors and long cables- Sensor status indicator- Temperature sensor indicator- °C & °F temperature units- Sample ID setting- Detailed calibration data- Auto stable, Auto hold, and Real time measurement modes- Customizable meter kit - up to 15 meter-sensor kit combinations- Hands-free testing- Ergonomic design- Multi-language options- Versatile channel and adaptive display- Up to 2 simultaneous calibrations and measurements- Automatic sensor recognition function- Data transfer via USB or wireless communication- Printer communication- 3 years meter warranty
-
product
Conductivity Logger Sensor
NUL-215
This logger sensor is based on a probe with two electrodes with known surface area and distance between them. A signal is supplied to the electrodes and by testing the signal behavior, the conductivity of the solution is calculated
-
product
Online pH Controller
LD-LOPC-A10
Online pH ControllerLD-LOPC-A10features 1 to 3 points pH calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. The automatic electrode slope display helps user decide when to replace the sensor.
-
product
Fully Automatic Transformer Oil Test Set
OTS-A series
The Motwane Manufacturing Company
OTS-A series is fully automatic microprocessor based transformer oil test set designed with advanced features to measure breakdown voltage of insulation oil accurately. The OTS-A Series preprogrammed with worldwide acceptable standards.The user can define customized standards. The large LCD display with menbrane key pad for easy operation. It is provided with internal memory for 100 data storage & built-in thermal printer for onsite report. The kit is protected by automatic detection of poor input ground.The acrylic oil test vessel provided with adjustable electrode gap setting. The voltage calibrator for on site calibration saves cost & time of user.
-
product
Industrial pH Meter (Four-Wire Analyzer)
HP-200-K
One-touch calibration function Realizes gentle measurement by combination with lead-free ORP electrode
-
product
pHTestr® 50 Waterproof Pocket pH Tester,
Premium 50 Series
The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.
-
product
Anti-Sulfurated Thick Film Type Resistors, Precision Type
ERJ-U2R/ERJ-U3R/ERJ-U6R Series
Panasonic Industrial Devices Sales Company of America
High Precision And High Resistance To Sulfurization In One Resistor!Panasonic's ERJ-U2R, ERJ-U3R, ERJ-U6R (ERJ-U*R Series) offers high precision and also provides anti-sulfurization characteristics that avoid an open circuit caused by a sulfide disconnection. High resistance to sulfurization is achieved through the use of an anti-sulfurated electrode structure and material in the manufacture of ERJ-U*R Series Resistors. AEC-Q200 Compliance and IEC 60115-8, JIS C 5201-8 and JEITA RC-2134C Reference Standards for the entire ERJ-U*R Series of High Precision, Thick Film Chip Resistors from Panasonic ensures optimal quality and reliability.
-
product
Conductivity Electrode
As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.
-
product
MANIFULATOR
As one of the most important module in Probe_Station, manipulator is an accurate system that probe micro distance() and contact on the electrode of semiconductor wafer, device. ECOPIA's Manipulator is very easy to use and probe arm's elastic plate is good to protect sample's surface, from being damaged by Z direction movement.
-
product
Synchronous GPS Based I/O Controller & Interrupter
interX
interX was originally developed as a measurement instrument for industrial and trunk pipeline anodic or cathodic protection systems. interX allows facilitate measurement of galvanic parameters (instant-off polarized potentials, pipe-to-soil potential) across a wide range of timing cycles. It is used to make synchronous disconnect and reconnect of protection electrodes (anode or cathode) or rectifier's from/to buried underground pipeline to perform measurements.
-
product
pH / mV Transmitter
DO9403T-R1
The DO9403T-R1 pH transmitter converts the output of a pH electrode, with temperature compensation, into a 4÷20 mA signal.
-
product
Meter with "3-in-1" pH/Temperature Combi Electrode
pH 6+
Multi-Point Calibration (up to 3 points) with Auto-Buffer Recognition - choice of USA, NIST or pure water buffer standards with ±0.01 pH accuracy
-
product
Reference Electrodes
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
product
Handheld Water Quality Meters
LAQUA EC220
Waterproof standard handheld meters with backlit LCD, shockproof & scratch-resistant non-slip casing, built-in electrode stand, and foldable meter stand in durable carrying case for routine water quality testing in the field.
-
product
pHTestr® 10 Waterproof BNC Pocket pH Tester
Simply choose the electrode best suited for your application, connect the pHTestr BNC 10, calibrate, and measure. Change electrodes to suit your application without having to purchase another meter. Order electrodes separately. Large display and tactile keypad allow for easy calibration along with USA and NIST auto-buffer recognition. Hold function freezes reading on the display for easy recording. Additional features include Valox® sensor housing, self-diagnostic error messages, a battery-life indicator, and an auto-off function to maximize battery life.
-
product
Capacitive H.V. Detectors (Contact)
213 HVD~226 HVD
Standard Electric Works Co., Ltd
● Excellent shock resistance.● Rugged nylon moulding.● Auto on (when voltage detected).● Excellent drop resistance.● Good vibration resistance.● Loud sound alarm indication.● Built-in proving and self-test circuit.● High bright color-coded LEDS.● Works from standard 9V battery.● Interchangeable contact electrode.● Use in all whether conditions.● Compatible with all link sticks.● Lightweight, robust & compact.● Models available from 11kV to 132kV.● Suitable for indoor and outdoor use.● Self(auto on) or manual arming.● Easy access to batteries.● Customized threshold on demand.● Auto off (if no voltage detected).● Waterproof design, protection class : IP65.
-
product
Potential Meters
Potential meters are basically electrometers which have extremely high input resistances in order to keep the feeding reference electrode free of load. This is necessary to maintain the true potential. pH - meters can be used as potential meters when fast reading is not required, because common pH meters are very slow. When the potential answer to current pulses is to be followed, potential meters are essential.
-
product
Portable pH/mV Meter with pH electrode, temperature probe
CyberScan pH 11
5-point Push-Button Calibration with Auto-Buffer Recognition for quick calibration with no calibration mistakes
-
product
pH/ORP Wet-Tap
3719
The Signet 3719 pH/ORP Wet-Tap allows installation and removal of pH or ORP electrodes, even under process pressure, without the need for process shutdown during routine electrode maintenance and calibration. Automatic process isolation is achieved during electrode retraction with a double O-ring seal on a unique and compact retraction assembly; no separate valve is required.
-
product
Solid State Relay
5200
The B/W 5200 Series solid state relays are offered in two basic types for use in a wide range of low and high sensitivity applications.Both 5200 solid state relays are designed to operate on either 115 or 230 volts AC at 50/60 hertz.Both models incorporate a low voltage sensing circuit.Furhtermore, both solid state relays are capable of performing control functions directly from electrodes suspended in a well or tank, the B/W Unifloat level sensing system, or various pilot devices such as pressure, flow and limit switches, thermostats and push buttons.
-
product
Panel-mount Type pH Meter (Four-Wire Transmission, 4 point ararm, Time sharing Proportional Control)
HP-960FTP
HP-960FTP industrial pH meter is a high-end pH meter with a four-point alarm and a time sharing proportional control function.It connects pH sensor and measures pH and temperature in the sample water.It can also be linked with a cleaning device via an external input, extending its automatic operation time.Many types of electrodes are available to match the sample properties.