Luminous Flux
-
Product
Integrating Sphere Based Spectroradiometer Systems
-
Spectroradiometer systems with integrating sphere for the measurement of UV-VIS-NIR spectral radiant flux (W/nm) and luminous flux (lm) and chromaticity metrics.
-
Product
High Power LED Photo-color-semi Automatic Selector
-
Shenzhen Chuangxin Instruments Co., Ltd.
Can divide LED in to several groups by chromatic coordinates, correlated color temperature, dominant wavelength or luminous flux.
-
Product
Integrating Spheres
-
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
Product
High Accuracy Spectrophotocolorimeter
LMS-3000
-
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
Product
LED Fast-Scan Micro-Spectrophoto Colori meter
8000
-
Shenzhen Chuangxin Instruments Co., Ltd.
The system can determine spectral power distribution, chromaticity coordinates, correlated color temperature, color rending index (Ra), color difference, peak wavelength, spectral half width, dominant wavelength, color purity, luminous flux, test for photometry colorimetry electricity of LED characteristics.
-
Product
PCE Series Opto-Electric Measurement System
-
Hangzhou Everfine Photo-E-Info Co., LTD
This system delivers various photometric, colorimetric and electrical parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
Product
RGB Laser Illuminance, Luminance & Optical Power Meters
TM6102/TM6103/TM6104
-
Accurately evaluate the white balance of displays that use lasers by measuring centroid wavelength and optical power, which are key characteristics in the evaluation of laser light sources. Designed to adjust and inspect RGB lasers. Meters measure radiant illumination, centroid wavelength, illuminance, luminance, chromaticity, Radiant flux (optical power) and luminous flux.
-
Product
Integrating Sphere
-
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
Product
GO-SPEX100 Goniospectroradiometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
GO-SPEX100 delivers photmetric, colorimetric, electrical comprehensive test function for LEDs, and built-in precision temperature control platform,not only for measuring the specific temperature of the photometric and colorimetric parameters of LED, but also to measure the characteristics curve of its photometric and colorimetric performance with temperature.The test parameters include: spatial luminous intensity distribution curve, luminous flux, spatial spectral distribution, relative spectrum, absolute spectrum, color parameter, forward current and forward voltage, etc.
-
Product
0.3M Integrating Sphere For Leds Luminous Flux Test
CX-0.3S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Thesystem are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.
-
Product
LED Tester0.3m-2m Integrating Sphere
CX-8000
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Product
Spectroradiometer
-
Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.
-
Product
Spectral Light Meters For Photometric And Colorimetric Measurements
-
Comprehensive range of spectroradiometers for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens), luminous intensity (cd) as well as the colorimetric characteristic values such as chromaticity coordinates (x,y,u',v') or color rendering index (CRI), etc.
-
Product
LED Goniophotometer for Lamps
880
-
Shenzhen Chuangxin Instruments Co., Ltd.
Be used to measure the luminous intensity distribution curve intensity data spread angle and equivalent luminous flux of luminaries. Computer controls the whole test process automatically with low cost and simple operations.
-
Product
Light Meters For Photometry
-
Comprehensive range of solutions for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens) and luminous intensity (cd).
-
Product
Luminance Colorimeter
-
RayClouds Photoelectric Technology Co.,Ltd.
Measurement parameters: luminance, chrominance, color temperature, flicker, Gamma, etc.Applications: mobile phone screens, small flat panel displays, TV displays, etc.
-
Product
Luminance Colorimeter
RD Series
-
RD series can measure not only luminance and chromaticity, but also response and flicker for display and light source.
-
Product
Luminance Color Meters
-
Konica Minolta Sensing Americas, Inc
Similar to Illuminance meters, luminance color meters are three element detectors that both measure photometric brightness falling upon a surface, as well as give color information.
-
Product
Neutron Flux Monitoring Systems
-
To monitor reactor core neutron flux and provide indication during all modes of reactor operation, and to provide trip signals to the Reactor Protection System (RPS) and the Reactor Manual Control System (RMCS).
-
Product
Magnetic Flux Leakage Testing
-
PRÜFTECHNIK Condition Monitoring GmbH
NOVAFLUX - Flux Leakage Inspection for Black or Bright Steel Bars
-
Product
2D Video Luminance Meter
LS-ELF
-
LS-ELF can record 15 frame’s 2D luminance data per second. Also LS-ELF can record the image while driving 60-80km/h speed. It can be used in many fields as Display, Light pollution, Lighting, Lab, etc.
-
Product
Soil Heat Flux Sensors
-
Soil heat flux sensors may consist of several thermocouples whose measurements are averaged, a single thermopile, or a single thermopile with a film heater. These sensors measure the rate of energy transferred through a surface. Data regarding the amount of energy stored in soil as a function of time is used in energy-balance and Bowen-ratio flux systems.
-
Product
LED Luminous Intensity Distribution Tester
LS860
-
LS860 Luminous Intensity Distribution Tester is a precise electronic instrument for measuring LED luminous intensity. It’s strictly designed according to LED standard requirements of CIE 127-1997 A or B Condition.
-
Product
Luminance Colorimeter
BM Series
-
There are various lineups such as hand-held type and measurement of ultra low luminance in short time.
-
Product
Industrial heat flux sensor
HF05
-
Hukseflux Thermal Sensors B.V.
The HF05 heat flux sensor is used to measure heat flux in industrial environments. It is covered with a stainless steel cover.
-
Product
Flux Meter
NF-100
-
NF-100 can perform stable high accuracy measurement because noise and drift are reduced by the structure of digital counter and integral V/F converter with use of operational amplifier.
-
Product
Luminance Probe
LP471LUM2
-
Photometric probe for measuring the LUMINANCE, spectral response according to the photopic curve, angular field 2°.
-
Product
CAS-200 Compact Array Spectrometer
CAS-200
-
Hangzhou Everfine Photo-E-Info Co., LTD
CAS-200 can quickly and accurately measure the spectral power distribution in the range of 380nm ~ 780nm, mainly measuring: the relative spectral power distribution, chromaticity coordinate, color temperature, color rendering index, color tolerance, peak wavelength, FWHM, luminous flux (with integrating sphere) of traditional lamps/light sources, single LED, LED modules and other electric light sources.