Load Banks
Test a power source by providing controlled amounts of load to create conditions found in thier application.
See Also: AC Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks, Resistive Load Banks
- Pickering Interfaces Inc.
product
PXI Solid State MUX, 4 bank, 40 channel
40-680-004
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
product
Load Banks
Power House Manufacturing, Inc.
Load banks manufactured by Power House are engineered to be smaller and lighter than the competition.
-
product
AC Load Banks
K-1000 Series
Kongter Test & Measurement Co., Limited
Load bank testing is vital to replicate and verify the operation of critical backup power systems such as diesel generators and uninterruptible power supplies (UPS). Kongter offers a wide range of customer-tailored AC load banks that excel in a range of load test applications and environments.
-
product
Load Banks
PARELO
Amfax introduce the latest generation of load banks we affectionately call PARELO. This range of load banks provides a combination of high performance passive resistive loads along with extreme flexibility of use. This is achieved by our unique FLEXI-phase Switching(TM) technology.. Designed primarily for offering high wattage loads for the aerospace, energy, automotive and transport sectors. PARELO load banks are a cost effective solution for companies requiring high wattage loads when testing their products.
-
product
Automatic Power Factor Controller
Power factor controlling based on the capacitor bank switching historyCapacitor is automatically disabled when it is deteriorated beyond a certain levelAutomatically learns the number of capacitors connected and the value.Capacitance-based power factor correction takes care of variation in voltage and frequency.Controlling based on VAR parameter and availability of built-in alarms Flexibility for site programmability of CT ratio suitable for any load
-
product
Resistive & Capacitive, Inductive AC Load Bank
RLC
Inductive & capacitive load banks are reactive only and must be used in combination with a resistive load bank to provide the desired load profile to test a power system. Reactive loads banks can provide either a leading power factor (Capacitive) or lagging power factor (Inductive).
-
product
Resistive & Inductive AC Load Bank
RL
Resistive & reactive load banks are able mimic motor loads and electromagnetic devices within a power system as well as purely resistive loads by offering the ability to set a specific power factor (pf). Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive te...show more -
product
AC Load Bank
XL750-XL800 Series
Mosebach Manufacturing Company
The XL750-XL800 Series load banks offer you a continuous load at various voltages in a compact, lightweight enclosure.
-
product
AC Load Banks
XL1000-XL1250 Series
Mosebach Manufacturing Company
The XL1000-XL1250 Series load banks offer you a continuous load at various voltages in a compact, lightweight enclosure.
-
product
Resistive Load Banks
R Series
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.
-
product
Battery Capacity Tester
BLU-T Series
Battery load bank BLU-T is a powerful and lightweight solution designed for condition assessment of telecommunication and radio equipment backup supply. This instrument can perform the battery capacity test on battery strings such as Pb, Li-ion, Ni-Cd, and others. It tests battery strings with voltages in the range of 0,9 – 70,5 V DC. As a special feature, the BLU110T model enables capacity testing of single PB, Ni-based as well as Li cells (with current up to 100 A).The capacity test is conduct...show more -
product
Variable Resistor Load Bank
REOLOAD 100
A variable resistor load-bank with fixed stages connected in parallel and switched in, as required, with an adjustable stage for fine trimming. Designed for testing equipment under load. 1000V (AC or DC). 250A and 2500
-
product
Uni-Therm High Current Electrosurgical Analyzer
A unique high power low inductance load bank enables performance testing up to 8 ampere RMS with a duty cycle of up to 100% making the analyzer an extremely versatile test instrument for calibrating and performance testing of conventional and high power electrosurgical generators. The load bank allows testing in a range of 0-5115 with a resolution of over 1000 steps providing high detailed power profiles. The Rigel Uni-Therm also advocates safe working practise by providing all necessary resistors within a single enclosure.
-
product
Outdoor Permanent Mounted Load Bank
Mosebach Manufacturing Company
Mosebach Pad Mounted Load bank is designed to be permanently mounted next to a generator for dedicated testing. Its unique design allows it to be one of the smallest on the market! This size enclosure will fit 50 kW, 75 kW or 100kW of testing ability. Also available in 300kW and larger load banks.
-
product
Battery Loading Unit
BLUe
BLUe series Battery Loading Units; portable instruments for controlled & monitored discharge of batteries. It is designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Single autonomous unit having inbuilt display, keypad and wireless communication with PC makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents. ...show more -
product
PXI 8 Bank 8 Channel 2 Pole Multiplexer
40-659-102
Model 40-659 is an 8 Bank 8 Channel Multiplexer module with 2-pole switching, It uses high quality electromechanical relays and is suitable for switching signals up to 2Amp, 300VDC/250VAC.The 40-659 module is suitable for multiplexer applications where two signals are required to be switched simultaneously, for example send and return signals in a telecoms system. It is also suitable for applications where reed relay based multiplexers do not have sufficient power handling capability such as switching medium power AC or DC loads or for slaving external relays, contactors and solenoids.
-
product
AC Load Bank (Rack Mounted)
K-1000 Rack Mounted
Kongter Test & Measurement Co., Limited
Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.
-
product
Load Banks
Power Test Dynamometer offers a complete high capacity load testing solution with our load bank and gen set testing systems. Capable of testing generators and AC/DC power sources, our load bank systems safely apply electrical loads across the entire spectrum of operation. By offering a one-stop-shop for your Load Bank and it's accompanying data acquisition software, Power Test is committed to Making Your Testing Easy.
-
product
Adjustable Load Banks
DSR-WB series
Power can be up to 20kW, depends on the resistance value and application- Support High Current up to 80A.- For some cases, can support 3 phase Rheostat application
-
product
PXI 18 Channel Data Comms MUX, 96-pin SCSI
40-735-902
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the ...show more -
product
AC Load Banks
XL500-XL600 Series
Mosebach Manufacturing Company
The XL500-XL600 Series load banks offer you a continuous load at various voltages in a compact, lightweight enclosure.
-
product
PXI 36 Channel Data Comms MUX, 96-pin SCSI
40-735-912
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the...show more -
product
DC Load Bank
K-900
Kongter Test & Measurement Co., Limited
K-900 series are your best choice DC load bank with Kongter’s updated solutions. This new series resistive dummy load includes a series customized load bank models that feature rugged design and and excellent performance. They facilitate your work for DC load and battery capacity testing. With different models of DC load bank, it covers a wide range from 12V to 480V nominal voltages with current up to 600A. Its big TFT touch screen with vivid display makes it more user-friendly for setting and operation. Kongter’s new PC software make it easy for measurement monitoring and report print out.
-
product
AC & DC Loadbanks
Regular load bank testing of generators provides an essential health check service to prevent diesel engine failure due to wet stacking. Wet stacking occurs due to under loading of the genset which results in wet un-burned fuel building up in the engine. This fuel build up will over time line the combustion chamber cylinders and cause a reduction of the engines rating and efficiency which will ultimately cause premature failure of the generator. Running the generator on load of 50% - 100% of the genset rating will allow the engine to reach the recommend operating temperature, which will burn off the choke deposits.
-
product
PXI Single 36 Channel MUX, SMB Connectors
40-735-912-S4
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the de...show more -
product
AC Load Bank (Resistive/Reactive)
K-1000 Resistive/Reactive
Kongter Test & Measurement Co., Limited
Resistive/reactive load banks are great choices for testing turbines, switchgear, rotary UPS, generators and UPS systems. They can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others. A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage.
-
product
Load Bank
Being the reckoned names in the industry, we offer world-class range of Load Bank that is manufactured with perfection. We offer in different configurations such as Resistive, Inductive, and Capacitive. Our entire product range has high compressive strength and ensures smooth operations. They are durable in nature and are delivered in stipulated time frame.
-
product
Data Center Load Bank
Mosebach Manufacturing Company
Mosebach’s Data Center Server Rack load bank, the SR family, is ideal for commissioning data centers. There are multiple models for varying voltages and power levels. The unit has a variable fan speed control which allows you to fine tune as desired.
-
product
Resistive AC Load Bank
AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
-
product
Battery Data Logger
BDL-3926C
Kongter Test & Measurement Co., Limited
BDL-3926C Battery Data Logger is wireless monitoring device for string voltage, cell voltage, current and temperature. It works individually to reflect battery status or co-works with Kongter’s other battery test equipments like battery charger and K-3980 DC load bank. For different battery systems, it has customized configuration from 12V to 480V or upper. And it has easy expansion for all battery systems.