Filter Results By:

Products

Applications

Manufacturers

Engine

drives a machine or core functionality.of software.


Showing results: 481 - 495 of 969 items found.

  • Pitot Tube Flow Meter

    PTFM-1000V2 - HORIBA, Ltd.

    The Pitot Tube Flow Meter, PTFM-1000V2 is a standalone interface for measuring exhaust gas flow rate of combustion engines. The system uses the tried-and-tested pitot tube principle with high-frequency transducers to accurately measure highly pulsating exhaust flows with a sampling rate of 1kHz. This rapid capture rate ensures that any pulsations or exotic behaviour in an engine is measured, and the unique design of the PTFM pitot tube means reverse flows can be measured with the same guarantee of sensitivity. The interface can be run standalone with a laptop, or seamlessly integrated to run alongside an analyser system without adding any more steps to the test cycle process.

  • PXI-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module

    778572-14 - NI

    7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • PXI-2512, 7-Channel, 10 A PXI Signal Insertion Switch Module

    778572-12 - NI

    7-Channel, 10 A PXI Signal Insertion Switch Module—The PXI‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module

    778572-10 - NI

    68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • 1/4" resolvers

    R90-11HT - Computer Conversions Corporation

    These resolvers are rated for reliable operation in predominantly especially hot temperature applications, having an operating temperature over a wide range of -67 to 400 degrees Fahrenheit. The robust proven High Temperature ratings makes these resolvers particularly well suited for especially high temperature environments as found in: oil industry deep hole drilling, jet engine guide vanes, turbine governors, steel processing and automated heat treating type applications.

  • DFDR Ground Replay

    avSCAN - Avionica, Inc.

    avSCAN has gained a growing worldwide following at airlines, militaries, airframe and engine OEM’s, repair stations, research groups, regulatory agencies, accident investigation boards, and educational institutions. Be in good company. avSCAN is so much more than a DFDR Data Ground Replay System. From its core architecture to its user interface and rich feature set, avSCAN has steadily grown to become the benchmark for flight data analysis.

  • Scalers / Converters

    DVIGear, Inc.

    Converter/Scalers provide two essential functions. First, they convert the input signal from one format to another (e.g. analog VGA to digital HDMI). Second, they allow the user to select the resolution of the output signal for display on a flat screen display or projection system. In many cases the quality of the output signal from our Converter/Scalers will be better than what is possible using a direct input on the display because of the price/performance limitations of consumer scaling engines.

  • FlexRay Interface Device

    NI

    FlexRay Interface Devices provide two fully functional FlexRay interfaces, allowing an individual engine control unit (ECU) to be connected to the interface when other cold-start nodes are not available. You also can use the interfaces individually to connect two separate FlexRay networks while maintaining full performance on each interface. FlexRay Interface Devices work well in applications such as hardware-in-the-loop (HIL) simulation, rapid control prototyping, bus monitoring, and automation control.

  • IndySoft for Calibration Management

    IndySoft Corporation

    The IndySoft Calibration Management workflow offers a rich feature set to manage the entire lifecycle of your quality assets. With support for leading enterprise platforms it's perfect for deployment in the corner lab of a startup manufacturing facility or a multi-site international quality-driven operation. With the IndySoft exclusive process modeling engine, companies can re-configure the event-driven workflows with checkpoints, rule sets, and documentation at every point along the equipment path, ensuring assets are handled according to their exacting requirements.

  • Vehicle Multiprotocol Interface Device

    NI

    The Vehicle Multiprotocol Interface Device excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals, such as hardware-in-the-loop (HIL) simulation, rapid control prototyping, bus monitoring, automation control, and more. The NI-XNET device-driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time for processing complex models and applications.

  • 12 Port PCI Express

    PEX 8615 - Broadcom Limited

    The ExpressLane™ PEX 8615 offers 12 PCI Express Gen 2 (5.0 GT/s) lanes, capable of configuring up to 12 flexible ports and fully conforms to the PCI Express Base Specification, rev 2.0. PEX 8615 architecture supports a high-performance DMA engine with four DMA channels and internal buffer space for internal descriptor support. Up to 256 descriptors are supported internally or alternatively descriptors can also exist in host memory.

  • 16 Port PCI Express

    PEX 8619 - Broadcom Limited

    The ExpressLane™ PEX 8619 offers 16 PCI Express Gen 2 (5.0 GT/s) lanes, capable of configuring up to 16 flexible ports and fully conforms to the PCI Express Base Specification, rev 2.0. PEX 8619 architecture supports a high-performance DMA engine with four DMA channels and internal buffer space for internal descriptor support. Up to 256 descriptors are supported internally or alternatively descriptors can also exist in host memory.

  • 8 Port PCI Express

    PEX 8609 - Broadcom Limited

    The ExpressLane™ PEX 8609 offers 8 PCI Express Gen 2 (5.0 GT/s) lanes, capable of configuring up to 8 flexible ports and fully conforms to the PCI Express Base Specification, rev 2.0. PEX 8609 architecture supports a high-performance DMA engine with four DMA channels and internal buffer space for internal descriptor support. Up to 256 descriptors are supported internally or alternatively descriptors can also exist in host memory.

  • Bird Strike Testing

    National Technical Systems

    Many people may consider flocking birds such as sea gulls, ravens, and pigeons to be a nuisance but otherwise harmless. However, to jet aircraft and individuals carried aboard, the possibility of a bird strike poses an existential threat. For instance, when U.S. Airways Flight 1549 crashed into the Hudson River in New York back in January, 2009, the subsequent investigations performed by the NTSB and FAA found that a double bird strike during take-off (one in each engine) caused the incident.

  • USB HD-SDI Video Processor/Capture Card with Overlay

    2246 - Sensoray Co., Inc

    Video overlay up to full screen at up to 1920x1080 SDI (HD/SD) and analog inputs DVI, SDI (HD/SD), and analog outputs Prescaled SD A/V compression engine with MPEG-1/2/4 output Up/downscaling on DVI and analog outputs Captures uncompressed HD/SD frames Generates "freeze frame" video from captured frames Video "zoom" on MPEG stream and DVI output Isolated general-purpose digital I/O: 8 in / 4 out USB 2.0 interface

Get Help