Partial Discharge Calibrators
See Also: Partial Discharge Detectors
-
Product
Electrostatic Discharge Generator
SKS-0230I
-
Shanghai Sanki Electronic Industries Co., Ltd.
The electrostatic discharge generator SKS-0230I has high reliability, the host itself can withstand 30kV electrostatic discharge test; 7-inch touch LCD screen, simple interface, convenient operation; unique combination test mechanism, multiple modes, arbitrary combinations of parameters, continuous testing; Equipped with a file management system, which can save commonly used test parameters, and can also import and export test parameters through U disk; has temperature and humidity monitoring function, real-time display of temperature and humidity indicators of the experimental environment; high- pressure precision resistance and capacitance combination, long service life, and Easy to replace to meet different experimental requirements (150pF, 330pF, 330Ω, 2000Ω);
-
Product
Calibration Kit
WR-12
-
This precision calibration kit contains a flush short, offset piece and broadband load which allows for a full 12-term port calibration.
-
Product
Field Calibrator of Three Phase Energy Meter
SY3640
-
Hong Kong Songyang Industrial Ltd.
SY3640 three phase energy meter field calibrator is a high precious three phase energy reference meter; it uses the advanced technology and latest electronic components available in the world, and use high speed DSP as the main processor to ensure the accuracy and long time stability.
-
Product
Real-Time Online Monitoring to Detect and Analyze Potential Partial Discharge (PD) Signals and Insulation Faults using UHF, AE, and HFCT
PDMonitor
-
Power Monitoring and Diagnostic Technology Ltd.
The PDMonitor, which utilizes Ultra High Frequency (UHF), Acoustic Emission (AE) and High Frequency Current Transformer (HFCT) sensors and is designed to conduct real time online monitoring to detect and analyze potential Partial Discharge (PD) signals and insulation faults before they lead to breakdown or catastrophic failure in power assets. The system provides the developing trend of the PD, when occurring, as alarms in real time, thus helping to predict the insulation degradation status of the asset, prevent sudden accidents, and provide an effective database for Condition-Based Maintenance (CBM) of power assets.
-
Product
IDevice Calibrated Measurement Microphone
IMM-6
-
The Dayton Audio IMM-6 is a professional-quality measurement and recording microphone that is designed to work with the entire suite of Apple “iDevices” – iPad, iPhone, and iPod. The rugged construction and compact size make it the perfect companion for audio professionals who must work on-location performing acoustic analysis, monitoring audio levels, or recording. Each IMM-6 is individually hand-calibrated using a laboratory-standard measurement microphone, for consistent, repeatable measurements that match the level of precision previously offered only by expensive stand-alone microphones.
-
Product
Calibrator
-
Sanwa Electric Instrument Co., Ltd
Is an equipment used to adjust an instrument accuracy, often associated with a specific application: temperature, pressure, weight.
-
Product
Electrostatic Discharge Test
-
The electrostatic discharge test is designed to determine the ability of equipment to perform its intended function without permanent degradation of performance as a result of an air discharged electrostatic pulse. Electrostatic discharge is the result of an unbalanced electrical charge. Typically, it is created by insulator surfaces rubbing together or pulling apart. A transfer of electrostatic charge between bodies (materials, components, etc.) at different electrostatic potentials is caused by direct contact.
-
Product
Calibration Services
-
Tempsens Calibration Centre is an independent unit of Tempsens instruments (I) Pvt. Ltd. We have calibration laboratories at Vadodara (Temperature Range for Contact Type Sensors -196 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C) and Bangalore (Temperature Range for Contact Type Sensors -35 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C).
-
Product
Three Phase Portable Energy Meter Calibration Equipment
GF302D1
-
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
Product
Calibration Lead - Precision Resistor Modules
40-975-037-02-1m
Cable Assembly
The cable assembly is specifically designed to connect to the 37-Pin D-Type calibration port located on the front panel of Pickering Interfaces Precision Programmable Resistor Modules 40-293 and 50-293 enabling calibration via an external DMM.
-
Product
Thermocouple Calibration Furnace
9118A
-
The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics.
-
Product
Partial Discharge Detector
PDD 100
-
The Insulator partial discharge detector is a state-of-the-art technology used by NASA. The Parabolic design of the disc helps to maintain and detect ultrasound from safe distance of 100 Meters. Enhanced ultrasound detection is provided to the device, by combining the features of the already proven Ultra sound sensing technology with extended range and sensing capabilities. A pistol like grip laser pointer, and rifle sights make the Insulator partial discharge detector easy to handle and use.
-
Product
Discharge Units
-
ENTES Discharge Units are used in capacitor banks and provide quick discharge over short periods of time.
-
Product
Decade Box, Calibrated W/Data, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL D
-
The 72-7265 CAL D from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Calibration and Repair Services
-
Additel calibrations provide you with high confidence and low uncertainty for your standards. Our accredited calibration laboratory utilizes primary-level piston gauge systems and high-performance controllers to provide services for the entire Additel product line. In addition, our repair technicians which are ready to help, should you have trouble with the Additel units you own.
-
Product
Digital Light Meter, Calibrated
93-172-C
-
Measures incandescent, fluorescent, metal halide, high-pressure sodium and halogen lampoutput. Color and cosine-corrected for enhanced accuracy. Measures up to 50,000 lux. Peak and data hold means no lost measurements. Accessories included: (1) 9V battery and carrying case. Lifetime Limited Warranty.
-
Product
Calibrated, Integral Isolator Noise Sources
-
Calibrated, Integral Isolator Noise Sources by Pasternack
-
Product
Differential Calibration Substrates
-
The GGB Industries, Inc., line of DIFFERENTIAL CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected.
-
Product
Bench Power Supply, Calibrated, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL
-
The 72-2690 CAL from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
Mechanical Calibration Kit
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.
-
Product
Flow Calibration
-
Trescal provides full Flow Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Flow Calibration services can be delivered at your site or at our lab. Accreditations for our flow calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Calibrate Camera RAW Image Files
SpyderCUBE™
-
Accelerate RAW processing by taking one reference shot under any light condition to set the white balance, exposure, black level and brightness right from the start for your entire series of photos.
-
Product
IndySoft for Calibration Management
-
The IndySoft Calibration Management workflow offers a rich feature set to manage the entire lifecycle of your quality assets. With support for leading enterprise platforms it's perfect for deployment in the corner lab of a startup manufacturing facility or a multi-site international quality-driven operation. With the IndySoft exclusive process modeling engine, companies can re-configure the event-driven workflows with checkpoints, rule sets, and documentation at every point along the equipment path, ensuring assets are handled according to their exacting requirements.
-
Product
Calibration Software
-
Simplify your calibration through advanced software from Transmille. ProCal can automate your test equipment and increase productivity while reducing errors.
-
Product
Instrumentation Calibration Services
-
We offer a range of instrumentation calibration services for Kemo products in addition to other signal conditioning and sensors. We have many decades of experience in the manufacture, test and calibration of our instruments and those of our competitors. Please refer to the list below for an example of our calibration options, all equipment used within our calibration department is calibrated and traceable to a UKAS accredited National standard:
-
Product
Calibration Services
-
Trescal US is accredited to ISO/IEC 17025, ANSI/NCSL Z450-1 and ANSI/NCSL Z540.3 through A2LA. Trescal has one of the largest scopes of accreditation in the country for electronic, physical and dimensional domains as well as being a factory-authorized service center for many International manufacturers.
-
Product
Loop Calibrator
6500 LC
-
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
Product
Multi-Axis Calibrator
XM-60
-
XM-60 is a laser measurement system capable of measuring errors in six degrees of freedom along a linear axis, simultaneously from a single set-up. It provides a powerful diagnostic tool measuring all geometric errors in the axis from a single capture. For users of volumetric compensation XM-60 provides quick and accurate method of data population. All measurements are made optically allowing use in any orientation.
-
Product
Calibration Kit
N1801
-
*, *N1801 Calibration Kit, *Frequency Range: up to 18 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.





























