Partial Discharge Calibrators
See Also: Partial Discharge Detectors
-
Product
Calibration services
-
Transcat Calibration Services offers the widest scope of ISO/IEC 17025 accreditation in the industries we serve. In fact, we are accredited for over 99% of our capabilities, and more than 95% of the calibrations we perform are accredited.
-
Product
Decade Box, Calibrated W/D & U, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL DU
-
The 72-7265 CAL DU from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Class 2 Sound Level Calibrator
SPC70
-
The SPC70 is a Class 2 sound level calibrator suitable for periodic testing of sound level meters and verifying their accuracy before and after readings, in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB. The output is accurate to 0.5dB with low levels of harmonic distortion. The SPC70 is compatible with the Martindale SP79 Class 2 Sound Level Meter and other meters with microphones up to 25mm.
-
Product
Battery discharge testers
-
The battery discharge testers are used to test batteries by discharging them in a specified mode: given resistive load, fixed discharge current, etc. Depending on the required power rating, various sizes are available from manually transportable testers to multiple electronically controlled units in a master/slave configuration. Five Series of standard models.
-
Product
Voltage And Current Calibrator
-
Precision Mastech Enterprises Co.
A precision instrument designed to generate (source) and measure precise electrical signals.
-
Product
RTC Reference Temperature Calibrator
-
AMETEK Sensors, Test & Calibration
Our most advanced and accurate portable temperature calibrator with the widest available temperature range. One of its great features is the patented DLC system for perfect temperature uniformity in the insert – even when calibrating large sensors or many sensors at a time.
-
Product
Insulation Tester Calibrator
DecR
-
SCOPE offers High Resistance, High Voltage Decade Resistance Box - DecR. It contains number of smartly configured precision resistors. They are arranged in such a way that user can obtain desired resistance value by selecting appropriate decade switches. DecR is designed using the high quality specially selected resistors. These range of high ohm resistance decades are ideal for variety of applications, having a voltage rating up to 5 kV. It covers the resistance range from 1 kilo ohm to 1 tera ohm. DecR can also be customized as per requirement. DecR is housed in a rugged case and available in 3 / 4 / 6 / 9 decades or in binding post configuration
-
Product
VNA Calibration Kits
-
Standard calibration kits used for manual network analyzer calibration
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
-
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
Product
Pressure Calibrator
HPC50
-
AMETEK Sensors, Test & Calibration
The HPC50 handheld pressure calibrator is an intrinsically safe, dual pressure calibrator with options to add an additional two external pressure or temperature modules. The HPC50 pressure calibrator combines the features you love from the HPC40 with improvements like, better battery life an improved display, an extra external module connection, and of course intrinsic safety.
-
Product
High Precision Angular Positioning, Calibration and Geometry Inspection
LabStandard COMPACT
-
Rotary Precision Instruments UK Ltd
Designed for horizontal or vertical applications with a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
Product
Test Equipment Calibration
-
EMC Technologies can provide convenient, local, NATA accredited calibration services which greatly reduces lead time and costs for EMC test equipment. In the past these items had to be sent overseas or to expensive government laboratories. We can calibrate these items against common standards such as CISPR 16 (and subparts), IEC 61000-6-X series, ANSI C63.4, ANSI C63.5 and ARP 958.
-
Product
Calibration Segment Arm
-
A torque analyzer or a torque sensor are a finely tuned instrument designed for testing and monitoring torque applications. In order to maintain accuracy, it is crucial that torque measuring equipment be properly calibrated regularly. Segment arm is engineered for calibrating torque analyzers and sensors and ensuring instruments are traceable to National or International Standards, such as N.I.S.T and ISO.
-
Product
Calibration And Certification
-
We also offer a wide range of Tools and Calibration Artifacts for Portable Coordinate Measuring Arms and Laser Trackers. Some of these artifacts we can also supply Certified with a NIST Traceable certificate. We also supply accessories including batteries, cables and other Misc tools.
-
Product
Spectral Irradiance / Illuminance Calibration Standards
-
Standard lamps calibrated in illuminance and spectral irradiance. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Calibration Kit
S2611
-
*S2611 Calibration Kit, * Frequency Range: up to 26.5 GHz, * Impedance: 50 Ohm, * Connector type: 3.5 mm female.
-
Product
Multiport Calibrated Measurements With Switch Instruments
S95553B
-
This application provides a macro which enables full multiport error correction and measurement capabilities using external switch instruments such as the M9164A/B or M9165A/B PXI Solid-state Switch Matrix. The software includes an easy-to-use measurement wizard that simplifies measurement procedures and reduces the setup time of complicated multiport measurements. The VNA displays measured multiport S-parameters.With the combination of M980xA PXIe VNAs and M916xA/B switch matrix, up to 66 ports (2 VNAs (4 ports and 6 ports M980xA), plus 4 modules of 2x16 M9164A/B) can be configured and supported. Measurement specification is supported when using the M9164B/M9165B 9 GHz switch modules.
-
Product
Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
SEM1605/P -
-
SEM1605/P - Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
-
Product
Calibrator for Battery Charger-Analyzers
VCM-100
-
The VCM 100 is an instrument designed to verify the performance and to calibrate Battery Charger-Analyzers used on Nickel-Cadmium, Lead-Acid and other types of batteries.
-
Product
Power Calibrators And Power Quality Calibrators
-
Calmet Smart Calibration Devices
A power calibrator and a power quality calibrator are both specialized instruments used to verify and adjust the accuracy of other instruments, but they focus on different aspects of electrical power.
-
Product
Calibration Services
-
Edgetech Instruments Inc. has the ability to calibrate any hygrometer (Edgetech Instruments or other manufacturers)Edgetech Instruments performs NIST traceable calibrations and is compliant with ANSI/NCSL Z540-1 and ISO 9001Calibration capabilities include 0-95%RH, dew points down to -75C, traces of oxygen to 10ppm
-
Product
Temperature Calibrators
-
We offer temperature calibrators in different shapes. We offer temperature dry blocks that can generate an accurate temperature, for example for temperature sensor calibration. We also offer electrical temperature calibrators that can measure and simulate various temperature sensors (RTDs and thermocouples). We also offer high-accuracy reference temperature probes.
-
Product
Calibration & Testing Unit for AC & DC Meters
-
Supreme Instrument Laboratories
Calibrator for calibration and testing of A.C. Milliammeters, Ammeters, Voltmeters, and D.C. Microammeters, Milliammeters, Ammeters, Millivoltmeters and Voltmeters having following technical specification
-
Product
Battery Charge And Discharge Test System
9841
-
*Easy user interface*Measure Voltage, Current, Power, KWH, AH, Temperature, Reference Voltage*Accuracy Measure Time*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery. *The test result will be stored to ACCESS data
-
Product
Decade Box, Calibrated, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL
-
The 72-7270 CAL from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
Photometric Ozone Calibrator
Model T703
-
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
Product
Lens Calibration
SpyderLENSCAL
-
A fast, reliable method of measuring and adjusting the focus performance on your camera and lens combinations.