Partial Discharge Calibrators
See Also: Partial Discharge Detectors
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
Electronic Calibration Module
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
Electronic Calibration Module
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Sensor Cable, 5 M
E1739A
Calibration Cable
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 26.5 GHz, Type-3.5 Mm (m) 50 Ohm
85520A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Linear Measurement Kit
55280A
Mechanical Calibration Kit
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (f)
85563A
Mechanical Calibration Kit
Combines an open, short, and load standard in a compact unit that is easy to handle and lightweight
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (m)
85562A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-F, 75 Ohm
85039B
Mechanical Calibration Kit
The Keysight 85039B calibration kit, with option M0F, contains male and female type-F open, short, and load standards. This calibration kit works with all 75 ohm network analyzers and test sets for measurement of devices with 75 ohm type-F connectors. The kit also includes type-N to type-F adapters. More economical versions of this kit are available by ordering option 00F for the female standards only, or option 00M for the male standards only. This kit is specified from dc to 3 GHz.
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Partial Discharge Inductor
Tracy
-
Cable testing and diagnostics with the BAUR tracy. The BAUR tracy partial discharge inductor induces a signal at the apparent fault location in the cable from outside. In combination with any PD measurement system, e.g., PHG TD/PD, the induced signal can be located and compared with the result of the partial discharge pre-location. The partial discharge location can thus be determined precisely.* Portable, battery-operated signal coupling device* Suitable for cables and cable accessories* Inductive signal coupling* Aviods costly, unnecessary replacements of PD-free cable accessories
-
Product
RF Electronic Calibration Module (ECal), DC To 13.5 GHz, 4-ports
N4431D
Electronic Calibration Module
The Keysight N4431D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4431D is a precision 4-ports ECal module that supports multiple selection of connectors like Type-N, 3.5 mm, 7-16 and 4.3-10 connectors and can be mixed up to 13.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Partial Discharge Meter
TMG
-
The partial discharge meter TMG was developed for Partial Discharge tests according to VDE 0434 and IEC 60270.
-
Product
Partial Discharge Monitor
INDIPARD
-
INDIPARD, a low-cost measuring device for partial discharge monitoring.
-
Product
Portable Switchgear Partial Discharge
PD-SG1
-
The PD-SG1 is a dual transducer Switchgear PD detection instrument. The unit detects TEV signals generated by internal discharge, as well as acoustic discharge generated by surface tracking or corona.
-
Product
Partial Discharge Detector
PXDP-II
-
The PXDP-II partial discharge meter is a portable device that performs detection and measurement of partial discharges in electrical devices or components. It records partial discharge measurements for analysis and diagnosis through the optional PC software. The PXDP-II can be used in various applications and complies with IEC 60270.
-
Product
Partial Discharge Measurements
MPD 500
-
The MPD 500 simplifies routine factory partial discharge measurements for electrical insulation systems. Engineered with OMICRON's long time experience, the MPD 500 is optimized for routine tests in high throughput environments.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Online Partial Discharge Monitor
ASM-E
-
The ASM-E is a permanent partial discharge monitor for cables, switchgear and other high voltage assets.The ASM-E can be configured with up to 128 PD sensor channels. If excessive discharge is detected, the ASM-E raises an alarm that can be configured either locally or by email/SMS. This enables the long-term assessment of plant conditions to be carried out quickly and easily, from any remote computer.
-
Product
Partial Discharge Simulation Devices
-
Hangzhou Xihu Electronic Institute
Simulation device of cable PD faults, simulation device of switchgear PD faults, simulation device of GIS PD faults, simulation device of transformer PD faults.
-
Product
Partial Discharge Locator
INDIPOINT
-
Ultrasonic directional microphone for the location of PD The very best maintenance instrument for partial dischargetrapping in medium and high voltage plant.
-
Product
Partial Discharge Detecting Systems
-
Hangzhou Xihu Electronic Institute
Cable PD detecting and positioning system, transformer PD detecting and positioning system, switchgear PD detecting and positioning system, GIS PD detecting and positioning systems.
-
Product
Partial Discharge Test Set Up
-
This testing set is of great use in industries for various testing applications. We strictly follow all the guidelines while manufacturing this Partial Discharge Test Set Up.
-
Product
PARTIAL DISCHARGE test set
pdnt02
-
International Biological Laboratories
This Test Kit is used for non-destructive means of assessing the quality of high voltage transformers, motors, cables etc., which are used in generation & distribution of electric power.
-
Product
Electronic Calibration Module (ECal), 26.5 GHz, 3.5 Mm, 2-port
N4691D
Electronic Calibration Module
The Keysight N4691D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4691D is a precision 2-port ECal module that supports 3.5 mm connectors up to 26.5 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4691D is included for securing your ECal module and accessories.
-
Product
Partial Discharge Expert Diagnostic and Location System
PDExpert
-
Power Monitoring and Diagnostic Technology Ltd.
The PDExpert is PMDT's third level of Partial Discharge (PD) Expert Diagnostic and Location System. It is a powerful, portable, multi-channel system of impeccable design used to analyze and pinpoint PD signals coming from a power asset within centimeters while the power system is energized. The system consists of UHF, AE, HFCT and ultrasonic sensors, one advanced UHF/PD signal processing unit, one oscilloscope, filters and other accessories.The system employs ultra-high speed data acquisition and advanced digital signal processing technologies, compares the UHF, AE and HFCT signals of different frequency ranges to determine if it is PD or noise, and locates the source in power assets accurately by utilizing Acoustic-Electromagnetic Combination Location Technique, time Difference of Signals' Arrivals (TDOA), and 3D Positioning Technology.
-
Product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
-
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Product
Partial Discharge Tester
19501-K
-
Chroma Systems Solutions, Inc.
The Chroma 19501-K Partial Discharge Tester is an instrument equipped with AC hipot test and partial discharge detection functions, providing 0.1kV~10kV of AC output, 0.01μA~ 300μA of leakage current, and 1pC~2000pC partial discharge detect ion range for measurement. Chroma 19501-K Partial Discharge Tester is compliant to the IEC60270-1 standard in particular the partial discharge testing requirements for high voltage.
-
Product
Partial Discharge and Tan Delta
PDIX Series
-
PDIX is a combined partial discharge and tan delta cable diagnostic testing system. By combining HVI’s VLF products with PDIX products, users can perform VLF AC withstand, partial discharge detection, and tan delta measurement on medium and high voltage cables, rotating machinery, and other apparatus with one integrated package fully supported by HVI & PDIX.
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
Mechanical Calibration Kit
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.