Showing results: 526 - 540 of 707 items found.
-
DYNOmite Dynamometer
Heavy-duty toroidal water-brake or large eddy-current absorber, S-beam electronic torque transducer, high-flow manual (or optional electronic) engine load control, DYNOmite data-acquisition computer, rigid-frame engine test stand, wall (or stand) mounted control console, absorber to engine-block mounting adapter, heavy-duty input shaft, calibration arm, stainless-braided hoses, and full-function data wiring harness.
-
SONOSCAN T -
SONOTEC GmbH
The ergonomic dual element probes for Non-Destructive Testing from the SONOSCAN Series comply with the DIN EN 12668-2 Standard and can be used to test metals, plastics and ceramics for imperfections such as cracks, inclusions, blowholes and other discontinuities. The transmitter-receiver probes manufactured in Germany are powerful, robust ultrasonic transducers which are compatible with the ultrasonic flaw detector SONOSCREEN ST10 or the thickness gauge SONOWALL 70.
-
Extech Instruments Corporation
Digital Force Gauge with a 5 digit LCD display and peak hold. Exclusive load cell measurement transducer. Over range, low battery and advanced function indicator. 5kg/176oz/49 Newtons measurement capacity. Basic accuracy of 0.4-percent. Complete with tension rod, carrying case and 4 adapters (flathead, cone, chisel and hook for tension), and 6 AA batteries.
-
779005-01 -
NI
±5 V to 24 V, 6 Differential/Single-Ended Channels, 500 ns C Series Digital Module - The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis.
-
779005-02 -
NI
±5 V to 24 V, 6 Differential/Single-Ended Channels, 500 ns C Series Digital Module - The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis.
-
G.R.A.S. Sound & Vibration A/S
It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation
-
DP10 -
Validyne Engineering
The DP10 Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full scale output of 30 mV per volt at 3kHz. The unit operates with carrier system including the Validyne CD15 since wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator.
-
Krohn-Hite Corporation
Krohn-Hite Wideband Power Amplifiers are designed to meet today's industrial needs where wideband, precision performance is required. Applications include: meter calibration, piezo transducer driving, bridging applications requiring high input and low output impedance, low distortion ac power source, ion beam deflection, vacuum tube driver, ink jet testing and design and many more.
-
IMV Corporation
A motion is sensed by a displacement detector, a current is fed to the coil to get back the pendulum mass to the original position. This current will be proportional to the acceleration, that is converted to an output voltage. The Servo type accelerometer is for the Earthquake Monitoring or measurements of micro tremor on the Civil Engineering Structures because of its higher sensitivity and stability or more accurate phase responses in the lower frequency range than those of other vibration transducers.
-
PVA TePla Analytical Systems GmbH
The SAM Line offers easy-to-use scanning acoustic microscopes for process control and quality assurance as well as for research applications. The individual models are derived from a component platform that complies with industry standards and incorporates cutting-edge production and manufacturing technologies. Thanks to their new high-frequency and transducer technology, our acoustic microscopes enable detailed acoustic analysis in the ultrasound range up to 400 MHz.
-
DYNOmite Dynamometer
Wide medium inertia roll assembly with our machined-in "traction grooves," quick-adjust wheelbase front mount, dual roll-on ramps, tie downs, casters, roller guards, eddy-current absorber (with a step-up drive), full-bridge torque arm transducer, electronic auto-load control, DYNOmite data-acquisition computer, DYNO-MAX software, inductive RPM pickup, AC power supply, and data wiring harness.
-
Pacific Instruments, Inc.
Series 6800 for laboratory applications is a ready-to-run, high performance measurement system. Enclosures are 3U rack mountable or can be used right on the desktop. 6800 units come equipped with a conditioner, amplifier, filter and digitizer. Each channel has a front mounted connector specific to a measurement type: RJ-45 for 8-wire bridge transducers, BNC for voltage or ICP/IEPE inputs or a 3-wire military grade connector.
-
27MG -
Olympus Corp.
The Olympus 27MG is an affordable ultrasonic thickness gage designed to make accurate, measurements from one side on internally corroded or eroded metal pipes, tanks, and other equipment. It weighs only 12 oz. (340 g) and is ergonomically designed for easy, one-hand operation. Thickness range 0.50 mm to 635 mm (0.020 in. to 25.0 in.) depending on material, transducer, surface conditions, temperature.
-
930A -
Arbiter Systems, Inc.
Model 930A Three Phase Power Analyzer is an economical alternative to the Model 931A Power System Analyzer when the dc voltage measurement, transducer calibration and timer features are not required. The Model 930A has the same ac accuracy as the Model 931A with PowerDSA™ Digital Signal Analysis. Basic accuracy of 0.05 % of reading and 0.05 ° phase, harmonic analysis, and full three-phase capability are standard.
-
RDA -
Mountz Inc.
The run down adapter (RDA) is designed to provide consistent and reliable torque readings for use with power driven torque control tools. The RDA’s reduce the impact and irregular peaks that cause poor repeatability. Each RDA has an effective torque range and will supply repeatable torque data within that range if used correctly. The run down adapter is mounted in-line between the tool drive and transducer.