Integrating Spheres
Uniformly scatter or diffuse light rays.
See Also: Goniophotometers, Spectroradiometers
-
product
Integrating Sphere FT-NIR Spectrometer
QuasIR 3000™
The QuasIR™ 3000 was designed from the ground up to offer the industry a new kind of NIR analysis solution – a solution that brings together the portability required to move NIR analysis closer to point-of-need, combined with unmatched spectroscopic performance for the fastest and most accurate results.
-
product
Integrating Sphere Light Sources
Integrating sphere light sources with LED based or continuous broadband emission spectrum for use as luminance standards for camera calibration, for the determination of veiling glare, for the adjustment of night vision devices and much more. Diameters in the range from 50 mm to 500 mm with options like monitor detector, signal output control by manual and remote apertures and much more.
-
product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
Conversion Kit for Kelvin Holders
KC-4
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary
-
product
Integrating Spheres
IP-Series
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
product
Spectrophotometer & Integrating Sphere Test System
LPCE-1
This Test System is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE and IES LM-79 for the measurement of photometry and colorimetry.
-
product
UV-VIS-NIR Spectrophotometer
UV-3600i Plus
UV-3600i Plus, the Multi-purpose large-sample compartment and the Integrating sphere attachment also feature three detector, enabling the high-sensitivity measurement of solid samples. LabSolutions UV-Vis is a next-generation Shimadzu UV control software pursuing efficiency of analysis. LabSolutions UV-Vis software with easy-to-use is included as standard.
-
product
Integrating Spheres
Integrating spheres are used especially for measuring divergent light sources such as LEDs. The light is introduced through the input port, then reflected many times by the highly reflective interior of the sphere until it illuminates the inner surface uniformly. A detector samples a small fraction of this light to measure the total power input. Ophir integrating spheres have a highly reflective diffuse white coating for measurements independent of beam size, position and divergence. There are several sphere sizes, apertures and wavelength regions available. The large IS6 series has 2 configurations for measuring divergent or parallel beams.
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
Integrating Sphere Solutions
An integrating sphere is a light collector which takes advantage of physical geometry to homogenize any radiation being emitted inside by relying on a high-reflectance coating material. Depending on the wavelength range the end user using a sphere with, different coatings have different advantages based on the application.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
Integrating Sphere with Side Assistant Opening
IS-*MA**P/IS-*MA**C
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12 tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp be tested up and down in the sphere. • Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option). • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is 0.5×0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C (Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m). • Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request
-
product
Transmission & Integrating Sphere FT-NIR Spectrometer
QuasIR™ 4000
The QuasIR™ 4000 was designed from the ground up to offer the industry a new kind of NIR analysis solution – a solution that brings together the portability required to move NIR analysis closer to point-of-need, combined with unmatched spectroscopic performance for the fastest and most accurate results.
-
product
Integrating Sphere Spectroradiometer System for LED
LPCE-2(LMS-8000)
LPCE-2(LMS-8000) is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 127-1997 and IES LM 79-08 standards, it recommends using an array spectroradiometer with integrating sphere and photometer head to test SSL products. LISUN GROUP developed LPCE-2 test system for LED products.
-
product
Constant Temperature Integrating Sphere
IS-*MT
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
Integrating Sphere With Holder Base
IS-*MA
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as T5/T8/T12, and all kinds of luminaries2. The hold base can be installed in the ceiling or down, it can be adjusted the height3. Hold base has four power cables connect to the outside Power Supply and max is 5KW4. The holder base is detachable. For some kinds of light sources you may need to change the position of the holder base.5. Diameter: IS-0.3M (0.3m), IS-0.5M (0.5m), IS-1.0MA (1.0m), IS-1.5MA (1.5m), IS-1.75MA (1.75m), IS-2.0MA (2.0m). Other sizes can be designed according to the customer’s request.6. The painting of integrating spheres is according to CIE Pub. No.84 (1989)
-
product
Precision Kelvin Holders
MH-4 Series
Integrating Spheres are essential tools for photometricresearch laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary.
-
product
Integrating Sphere Coating
SP-80
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. A good internal coating is essential forintegrating spheres. It is a special water based BariumSulphate (BaSO ) white reflective paint particularly suitablefor internal coating of Integrating Spheres. It offers an almost constant reflectance in the range of 380 nm to 780 nm (visible wavelength range).
-
product
IR/Visible Target Projectors
Santa Barbara Infrared’s reflective infrared and visible target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) and visible imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies, Infinity VSX Integrating Spheres and 300 Series Target Wheels.
-
product
Integrating Sphere Systems
An optical device for various purposes such as. measuring the radiant flux (optical power) from a laser diode, light-emitting diode (LED) or bulb.
-
product
Passive Component Integration - MATRIQ
The Passive is a highly customizable benchtop accessory that can integrate the passive components of your choice for convenient storage and integration into your test set up.We can customize the Passive module with a wide range of passive components: WDM couplers, splitters, circulators, band-pass filters, PM beamsplitters, MUX, DeMUX and more.Our spec sheet contains a selection of popular configurations.Please contact us to discuss your specific requirements at sales@quantifiphotonics.com.
-
product
LED Tester0.3m-2m Integrating Sphere
CX-8000
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
Passive Component Integration - PXIe
Passive Series
The Passive PXIe module is a highly customizable PXIe module that can integrate the passive components of your choice.We can customize the Passive module with a wide range of passive components: WDM couplers, splitters, circulators, band-pass filters, PM beamsplitters, MUX, DeMUX and more.Our spec sheet contains a selection of popular configurations.Please contact us to discuss your specific requirements at sales@quantifiphotonics.com.
-
product
UDT-Series Integrating Sphere Systems
Gamma Scientific offers a variety of pre-configured integrating sphere systems for use in conjunction with the UDT line of optical meters, with both 25 mm and 150 mm diameters.
-
product
Test Sphere Probe
CX-500
Shenzhen Chuangxin Instruments Co., Ltd.
Test Sphere Probe This sphere is intended to verify the degree of protection of enclosures for an IP2 Code per IEC 529. Sphere is hardened steel with chrome finish. TOP
-
product
System Integration
G Systems develops fully integrated systems and we know that both software and hardware are equally important to system design. Our focus on code quality and optimization ensures customers receive efficient and maintainable code. We specialize in LabVIEW development and all of our LabVIEW developers are certified developers or architects. We’re also highly skilled in mechanical and electrical hardware design and builds on a wide variety of data acquisition, signal conditioning, RF, and distributed communication platforms.
-
product
Benchtop Sphere (d/8°) Geometry Spectrophotometers
Hunter Associates Laboratory, Inc.
Diffuse d/8° benchtop sphere spectrophotometers are recommended for transmittance color and haze measurements of transparent liquid and solid samples, and color measurements of opaque samples where it is desired to negate the effects of sample gloss and texture, as is necessary in the color formulation process when determining the effect of pigment variations irrespective of surface characteristics.
-
product
Integrity Assessment
Accurate and up-to-date insight into the structural integrity of your pipeline gives you a reliable basis for prioritizing maintenance tasks and investments, business planning and mission-critical decisions – helping you optimize costs. Does the pipeline fulfill its functional purpose? Are day-to-day operations being hampered by flaws or anomalies? What is the expected remaining lifetime of the asset?
-
product
Integrated Current Sensors
FHS Series
*Standard package and small footprint*Cost effective*Standard SOIC 8 surface mount PCB
-
product
Integrated Vision System
GEVA 312T
The GEVA-312T is an integrated vision system complete with a 12” touch screen display, 1.6GHz dual core processor and two Gigabit Ethernet camera ports. The slim-line form factor maximizes control panel real estate for PLCs, motions controllers and non-vision related components. The GEVA-312T is a good choice for customers who are looking for a complete system that is low-cost, expandable and applicable for a wide range of vision applications.





























