Showing results: 286 - 300 of 410 items found.
-
Premier Electrosystems
Premier's gas detectors can be used to detect combustible, flammable and toxic gases, and oxygen depletion. This type of device is used widely in industries and can be found in locations such as on oil rigs, to monitor the presence of toxix gases or any other gases which can harm human life.
-
Fyrite Classic -
Bacharach, Inc.
The Fyrite® Classic is a tried-and-true instrument for measuring oxygen and carbon dioxide. The Fyrite® Classic is available for O2 or CO2, and each gas type of Fyrite® is available in multiple ranges to meet a variety of applications, from combustion analysis to incubators to anesthesiology.
-
GNL-2100 Series -
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-2100 analyzer is the online intelligent measurement instrument, which adopting advanced ion current oxygen sensor with single chip technology. N2%=100%-O2%. It has been widely used in the fields of nitrogen separation from air, fertilizer, petrochemicals and biological fermentation.
-
Lightel Technologies, Inc.
Workstations using pure hydrogen gas from a tabletop generator, tank supply, or oxygen, can achieve high enough temperatures to develop Fused Biconic Tapered devices, Power Combiners, Wavelength Division Multiplexers, Thermal Core Expansion devices, and many other products.
-
WITT-Gasetechnik GmbH & Co KG
WITT gas filters enable the finest filtering of impurities in technical gases such as acetylene, argon., oxygen, hydrogen, methane, carbon dioxide, helium, compressed air and ethylene. They thus protect downstream equipment and systems. Some gas filters are also referred to as gas cleaners.
-
Zero Two -
MSA
Modular system offering the widest range of control cards for use in an integrated fire and/or gas detection system. The Zero Two Series system can monitor any combination of the following: combustible gas, H2S, toxic gas, ultrasonic, oxygen deficiency and flame detection.
-
Labodam
Aging oven, Charpy/Izod impact tester, falling weight impact tester, heat sealer, lasting adhesive tester, melt flow indexer, notch cutter, oxygen index tester, primary adhesive tester, vicat softening temperature & HDT machine, vacuum leak tester
-
GNL-400 -
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-400 trace hydrogen analyzer adopts imported high-performance electrochemical sensor with latest micro computer technology. It has such functions of LCD display, upper & lower alarm, signal output and relay contactor alarm output. And can be used to measure the hydrogen concentration in nitrogen, oxygen and argon.
-
MemoRail Modbus A1405 -
ALVI Technologies
With the increasing demand for a compact and flexible solution to liquid analysis –ALVI Technologies has responded with a new twist in the existing MemoRail. We are pleased to announce the release of our new MemoRail Modbus A1405 N- Dual Channel Multiparameter Analyzer with Modbus that offers an optimal solution for integrating a compact, flexible, all digital analyzer in an extremely cost-effective manner!! Our Dual Channel Multiparameter Analyzer with Modbus can be used with Memosens and digital sensors such as pH (glass and IsFET), ORP (redox), oxygen, and conductivity (conductive and inductive). It’s also the only analyzer in its class that is suitable for use with a digital optical oxygen sensor. All sensor types can be used in any combination in the dual-channel version.
-
ARO-PR -
JFE Advantech Co., Ltd.
The Portable optical DO meter makes use of the fast-response optical DO sensor RINKO, maintaining its high-speed response performance (99% response < 7sec). The meter probe is equipped with a temperature sensor close to the sensing foil, and the measurements are made by simply inserting the probe into a DO sample bottle (the calibration is carried out using the National Metrology Institute of Japan (NMIJ) certified traceable gases standards). Differently from galvanic electrode sensors, the instrument does not require water sample stirring or fixing reagents, since there is no oxygen consumption. Thus, the required time to estimate dissolved oxygen is considerably reduced. The display unit shows the output instantaneously, and you can check the measured values in real time.
-
Electro-Tech Systems, Inc.
ETS 5000-Series controllers—with an industry-leading combination of features and economy—feature dual-function controllers for humidity, temperature, and third parameter control (e.g. pressure or oxygen). Our latest generation of microprocessor (PID) controllers offer precision and accuracy and can be used with or without software. All controllers include a sensor.
-
Edgetech Instruments
Edgetech Instruments Inc. has the ability to calibrate any hygrometer (Edgetech Instruments or other manufacturers)Edgetech Instruments performs NIST traceable calibrations and is compliant with ANSI/NCSL Z540-1 and ISO 9001Calibration capabilities include 0-95%RH, dew points down to -75C, traces of oxygen to 10ppm
-
Rapidox 2100-OEM-RSB-WALL -
Cambridge Sensotec Ltd
The Rapidox 2100 OEM-RSB-WALL is a wall mount version of our miniaturised 24V OEM oxygen (O2) analyser. The compact (4.5″ x 3.0″) circuit is integrated into a neat IP65 wall mount polycarbonate box, with a clear smoked hinged lid. Behind this is a clear OLED display and menu keypad. The box is completely electrically isolated and meets all UL and IEC standards for these types of enclosures. There are cable entry glands on the base for power cables and analogue / digital / alarm leads The analyser comes with a robust cabled zirconia sensor, which is ideal for providing fast and accurate remote in-situ gas analysis over the the full oxygen range 10-20ppm to 30% O2. An optional external pressure sensor socket is included as standard.
-
KM 5410 -
Kusam Electrical Industries Limited
* Hand-pump with filter to isolate dirt and particles.* Thermocouple offset adjustment ±3°C (6°F).* Automatic power off battery saver.* 2 channel display(LCD).* Display Back-Light.* Analyzer Directly Measures: Flue Gas Oxygen Content in % and Flue Gas Temperature in °F or °C* Analyzer Computes: When the measured oxygen level is below 17.9%, Flue Gas Carbon Dioxide content in %, , Excess Air in %(0 to 400%), Flue Natural Gas/Oil #2/Propane in %
-
Model 452 -
Teledyne Advanced Pollution Instrumentation
The Model 452 is a microprocessor based gas sensor for measuring high concentrations of ozone in oxygen or air with accuracy and dependability. The measurement principle is based on the absorption of UV light at 254nm. Readings are available in % by weight, or grams/Normal cubic meter. Temperature and pressure compensation up to 3 Bar Absolute is a standard feature.