Measurement Microphones
measure acoustic frequency, time and noise levels.
See Also: Microphones, Hydrophones, Mic
-
Product
PXIe 5-channel Source/Measure Unit, 500 kSa/s, 100 pA, 30 V, 500 mA
M9614A
Source Measure Unit
The Keysight M9614A is a PXIe five-channel source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 μV / 100 pA.
-
Product
Source Measurement Unit
DPS16
Source Measure Unit
The DPS16 offers high voltage DPS in a compact, 3U PXI form factor. The DPS16 supports 0V to +4V 0.3A or 0V to 12V 25.6mA with FVMI, FVMV, FIMV, FIMI modes. 16 channel can be ganged to support high current driving.
-
Product
Microphone Preamplifier
HT426E01
-
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
Product
MEMS Microphones
-
A MEMS microphone is an electro-acoustic transducer housing a sensor (MEMS) and an application-specific integrated circuit (ASIC) in a single package.
-
Product
USB Microphones
-
Easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic Is esignals with the highest quality.
-
Product
Ultrasound Microphone
M500
-
The M500 microphone is easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic signals with the highest quality. For recording with the M500, the BatSound Touch or BatSound Touch Lite software is used.
-
Product
Precision Source / Measure Unit, 1 CH, 1 PA Resolution, 21 V, 1.5 A
B2901BL
Source Measure Unit
The Keysight B2901BL precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
Precision Condenser Microphone
2575
-
Performance:Nominal Microphone Diameter1"1" Frequency Response: Characteristic (at 0 incidence) Random IncidenceRandom Incidence Open Circuit Sensitivity: 45 mV/Pa Resonant Frequency (90 Phase Shift)8000 Hz8000 Hz[1] Inherent Noise<10 dB(A) re 20 Pa<10 dBTemperature Range (Operating)TBD FTBD C Humidity Coefficient of Sensitivity (0 to 95%, non-condensing)0.001 dB/%RH
-
Product
Precision Condenser Microphone
377B02
-
1/2" free-field, prepolarized condenser microphone, typical sensitivity= 50 mV/Pa (+/-1.5 dB), 3.15 Hz to 20 kHz (+/-2 dB).
-
Product
Measurement Condenser Microphone
ECM8000
-
The ECM8000 is a specialized condenser microphone designed for use with real-time analyzers, such as our ULTRACURVE DEQ2496, to provide an accurate acoustic picture of the room. You can then use your graphic EQ to fine-tune your system's performance to perfectly match the characteristics of any acoustic environment.
-
Product
Precision Source / Measure Unit (1 Ch, 100 FA)
B2901B
Source Measure Unit
The Keysight B2901B precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
Microphone Arrays
-
One of the most important parts of an Acoustic Camera is the microphone array. It determines the spatial distribution of the acoustic microphones and therefore measurement performance of the whole system. In order to achieve the maximum possible performance in any given application, we offer a wide variety of microphone arrays. No matter if the measurement is beamforming, intensity or holography ... we have the right microphone array. For special applications we can design and build custom made microphone arrays according to the requirements of the application.
-
Product
Microphone Preamplifier
426B03
-
Performance: Nominal Microphone Diameter:1/4"Frequency Response: (0.1 dB) (re 1 kHz)5 to 126000 Hz5 to 126000 Hz Frequency Response
-
Product
Microphones & Accessories
-
Applied Research and Technolgy
Creative choices for recording, and USB mics for content creators.
-
Product
Microphone Preamplifier
426B31
-
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
Product
High Precision Source Measure Unit (SMU) - Hybrid Compatible PXI, 100ks/S Programming/Measurement Speed
52400 series
Source Measure Unit
Hybrid Compatible PXIFour quadrant operationHigh source/measurement resolution (multiple ranges)Low output noiseHigh programming/measurement speed (100k s/S) & slew rateOptional measurement logDIO bitsOutput profiling by hardware sequencerProgrammable output resistanceFloating & Guarding output16 Control Bandwidth SelectionMaster / Slave operationDriver with LabView/LabWindows & C/C# APISoftpanel GUI
-
Product
SparkFun Analog MEMS Microphone Breakout
ICS-40180
-
The SparkFun Analog MEMS Microphone Breakout makes it easy to work with the InvenSense ICS-40180 analog microphone. This board features an OpAmp to bring the output of the microphone to a usable level, allowing you to plug directly into an ADC on a microcontroller or something like the SparkFun Spectrum Shield.
-
Product
Microphone Calibration Workstation
9350C
-
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
Product
Measurement
DC Voltmeter
-
DC Voltmeter is used for measuring DC voltage coming to the input channels of ADC modules and FFT spectrum analyzers. The indicator displays the DC voltage mean value and root-mean-square deviation (RMSD) from the mean value of the selected channel signal. It is possible to change the averaging of the displayed value (0.1; 1, or 10 s) and to select a necessary channel of the ADC module and FFT spectrum analyzer or a virtual channel.
-
Product
Measurement
Power Meter
-
Power Meter is used for determining the power of the electrical current coming to the input channels of ADC modules and FFT spectrum analyzers, or that of the electromagnetic signal.
-
Product
USB Modular Source Measure Unit
U2722A
Source Measure Unit
The U2722A USB Modular Source Measure Unit is a 3-channel 20V/120mA that can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
SparkFun Electret Microphone Breakout
-
This small breakout board couples an Electret microphone (100Hz--10kHz) with a 60x mic preamplifier to amplify the sounds of voice, claps, door knocks or any sounds loud enough to be picked up by a microcontroller’s analog-to-digital converter. Each breakout comes fully assembled and works from 2.7V up to 5.5V.
-
Product
Measurement
Frequency Meter
-
Frequency Meter is used for measuring the frequency of the signal coming to the input channels of ADC modules and FFT spectrum analyzers. The indicator displays the measured frequency value (frequency of periodic oscillations) and signal cycle time corresponding to the measured frequency. It is possible to change the averaging of the displayed value (0.1; 1, or 10 s) and to select a necessary channel of the ADC module, FFT spectrum analyzer or a virtual channel.
-
Product
Microphones
-
MIC-01, MIC-02 and MIC-03 are low cost precision condenser electret microphones perfectly suited for laboratory and on-field acoustical measurements. They have identical performances but differ for their physical size; MIC-01 is preferable for fixed laboratory installations while MIC-02 is highly manageable due to its short length; MIC-03 is the best where space saving is a must. Their frequency response is individually tested against specifications and the sensitivity value is supplied. MIC-01 & MIC-02 & MIC-03 can be directly connected to your CLIO system's input.
-
Product
ICP Electret Array Microphone
130A23
-
Nominal Microphone Diameter: 1/4" Frequency Response Characteristic (at 0 incidence)Free-FieldInherent Noise (A Weighted)<30 dB(A) re 20 Pa<30 dB(A) re 20 Pa Dynamic Range (High)150Environmental Temperature Range ( Temperature Effect on Output (-10 to +50 C)<0.7 dB<0.7 dB[2] Influence of Axial Vibration Excitation Voltage 18 to 30 VDC18 to 30 VDC
-
Product
Measurement
AC Selective Voltmeter
-
AC Selective Voltmeter is used for measuring AC voltage coming to the input channels of ADC modules and FFT spectrum analyzers. The specific feature of the AC selective voltmeter is perfomance of voltage measurements on the main signal-carrier frequency, which allows to eliminate the harmonics influence on the readings.
-
Product
PXIe-4147, 4-Channel, ±8 V, 3 A Precision PXIe Source Measure Unit
786888-01
Source Measure Unit
PXIe, 4-Channel, ±8 V, 3 A Precision PXI Source Measure Unit - The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote four-wire sensing for accurate measurements. The sample rate of the PXIe-4147 can reduce measurement times, capture transient device characteristics, and help you perform current-voltage (I-V) characterization of devices-under-test (DUTs). With a high-speed sequencing engine, you can synchronize SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4147 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Pressure Measurement
-
A range of hydrophones for measuring pressure in ultrasound fields, covering acoustics parameters to meet the latest regulatory requirements needed for IEC62127-1, NEMA UD2 or FDA 510(k) submission.
-
Product
Gravity Measurement
-
Quantum gravity measurement is emerging as a new frontier in sensing, bringing the ability to passively detect objects and voids, through difficult to penetrate materials such as soil, rock, lead and water. Gravity measurement using cold atom interferometers is set to revolutionise nearly all industries from civil to oil and gas, mining to maritime, and medical to defence.





























