Measurement Microphones
measure acoustic frequency, time and noise levels.
See Also: Microphones, Hydrophones, Mic
-
Product
IDevice Calibrated Measurement Microphone
IMM-6
-
The Dayton Audio IMM-6 is a professional-quality measurement and recording microphone that is designed to work with the entire suite of Apple “iDevices” – iPad, iPhone, and iPod. The rugged construction and compact size make it the perfect companion for audio professionals who must work on-location performing acoustic analysis, monitoring audio levels, or recording. Each IMM-6 is individually hand-calibrated using a laboratory-standard measurement microphone, for consistent, repeatable measurements that match the level of precision previously offered only by expensive stand-alone microphones.
-
Product
NI-9231, 8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module
783610-01
-
8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module - The NI-9231 is a high-density sound and vibration module that can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. It can perform the high dynamic range measurements necessary for modern measurement microphones and accelerometers and features simultaneous sampling. The NI-9231 incorporates both a TEDS input path and 2 mA of IEPE signal excitation source that can be turned on and off, removing the need for external sensor power and reducing the complexity of the data acquisition system.
-
Product
Microphones
-
All these measurement microphones have a XLR connector and require a phantom power. They can be connected to specially equipped soundcards or pre-amplifiers, only.
-
Product
Microphone Measurement Capsule
TG MM1W
-
Interchangeable measurement microphone capsule for TG 1000 handheld transmittersTo calibrate ELA and PA systems in the theatre, at live concerts or at festivals
-
Product
2-Channel Front End
BEQ II.1
-
*Binaural, digital equalizer with 24 bit technology and USB interface.*The digital equalizer BEQ II.1 combines the characteristics of an equalizer, a two-channel front end and an A/D converter into one mobile and very versatile measurement tool.*Binaural, aurally-accurate recordings can be conducted easily with BEQ II. The AES/EBU interface allows a quick and easy expansion into a four-channel system, e.g. with the HMS III or HMS IV. Via the ADAT interface, up to four BEQ II units can be connected, allowing for eight-channel recordings.*Integrated signal conditioning allows common measurement sensors (Microphone, Line, ICP�) to be directly connected to the front end. In addition, separate pulse inputs are available e.g. for RPM data acquisition.*Thanks to the high-performance built-in battery - external DC power supply is also possible - and its low weight, BEQ II.1 is the ideal tool for either mobile or stationary operation.
-
Product
Class 1 Integrating Sound Level Meter
Castle Sonus GA116I
-
The Castle SONUS GA116I is a feature packed instrument that is fully compliant with IEC 61672-1:2002 Class 1, and IEC61252: 1993. This meter gives simultaneous Leq (rms. average) personal exposure (LEpd) and peak measurement for assessments to the Control of Noise at Work Regulations 2005. It has a high-specification, Class 1 measurement microphone and is cased in tough, crack resistant ABS plastic.
-
Product
50KHZ MEASUREMENT MICROPHONE
M50
-
The M50 is a precision engineered 50kHz omnidirectional measurement microphone ideally suited for acoustical measurements including high-end loudspeaker design and quality control, scientific research, measurements of ultrasonic or subsonic transducers, or any application where an extremely accurate free-field measurement microphone is required.
-
Product
23KHZ Reference Measurement Microphone
M23R
-
The M23R is a precision engineered 23kHz omnidirectional measurement microphone ideally suited for acoustical measurements including loudspeaker design and quality control, sound system setup and troubleshooting, room acoustics, or any application where an accurate free-field measurement microphone is required.
-
Product
SPL Calibrator -124 dBSPL @ 1 kHz
511ES124
-
The 511ES124 is designed to provide 124 dBSPL at 1 kHz to meet the needs of the low sensitivity microphones found in many high SPL measurement applications. The microphones used in Car Stereo competitions like dB Drag racing, IASCA, and USAC have had their sensitivities reduced to the point where 94 dBSPL may no longer be adequate for calibration.
-
Product
Measurement Microphone System
MK224SYS
-
The MK224SYS Type 1 measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 8 Hz to 18 kHz response, 50 mV/Pa sensitivity and a "A" weighted noise floor less than 14 dBA.
-
Product
Class 2 Integrating Sound Level Meter
Castle Sonus GA216I
-
The Castle Sonus GA216i is a feature packed instrument, fully compliant with IEC 61672:2002 Class 2. This meter gives simultaneous Leq and peak measurements for assessments to the Control of Noise at Work Regulations 2005. It has a high-specification measurement microphone and is cased in tough, crack resistant ABS plastic. To comply with the Control of Noise at Work Regulations 2005, this Class 2 Sound Level Meter enables you to assess Noise in the workplace at fantastic value.
-
Product
Measurement Microphones
-
All microphones are omni-directional and 48V phantom powered. The XL2 Analyzer microphones include an electronic data sheet. The Automated Sensor Detection (ASD) of the XL2 automatically reads this data sheet, and recognizes the microphone model, sensitivity and calibration data. This ensures accurate measurement results.
-
Product
PXI-4461, 204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module
779687-01
-
204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module—The PXI‑4461 is designed for sound and vibration applications. It provides two-channel dynamic signal generation and two-channel acquisition, and you can use one of six gain settings to configure your input range. The PXI‑4461 also includes software-configurable AC/DC coupling and IEPE conditioning. The PXI‑4461 includes the hardware and software needed to make precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive noise, vibration, and harshness (NVH); and machine condition monitoring.
-
Product
Measurement Microphone System
7052SYS
-
The 7052SYS Type 1.5TM measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 4 Hz to >20 kHz response, 20 mV/Pa sensitivity and a "A" weighted noise floor less than 20 dBA.
-
Product
PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module
781490-01
-
204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
Product
Microphone Interfaces
MEMS
-
Listen offers 2 MEMS digital microphone measurement interfaces from Portland Tool & Die, the laboratory-grade DCC-1448 and the low cost PQC-3048 for production line use.
-
Product
Test And Measurement System
TM400
-
The TM400 system was designed to provide the ideal link between calibrated test microphones and measurement equipment such as SIM®, SIA SMAART Live®, TEF® or other systems. By using a radio link, long cables can be eliminated thus saving time and providing opportunities for additional measurements to increase accuracy. The microphone can even be moved around in the venue while the audience is present – something that is impossible with a cabled measurement microphone.
-
Product
Measurement Microphone
UMM-6 USB
-
Precision condenser microphone for critical measurement and recording applicationsConnects to your PC or Mac via USB portTrue omnidirectional pattern with calibrated flat frequency responseRugged construction with high-quality componentsCompact design; includes sturdy carrying case with foam insertCompatible with most industry-standard measurement software
-
Product
PXI FPGA & Measurement Accelerator
-
Keysight PXI FPGA & measurement accelerator provide digital-pre-distortion (DPD) and envelope tracking (ET) measurements that are embedded in high performance FPGA processing cards.
-
Product
Two-Quadrant SMU For Battery Drain Analysis, 20 V
N6781A
-
The Keysight N6781A is a source / measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device under test (DUT) is an eBook reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.
-
Product
USB Modular Source Measure Unit
U2723A
-
The 3-channel 20V/120mA module can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
Precision Source / Measure Unit, 1-Channel, 10 FA Resolution, 210 V, 3 A DC / 10.5 A Pulse
B2911B
-
The Keysight B2911B precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
-
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
PXI-4132, 100 V, 2 W Precision PXI Source Measure Unit
780558-01
-
±100 V, 10 pA Precision PXI Source Measure Unit—The PXI-4132 is a programmable, high-precision source measure unit (SMU). It has a single isolated SMU channel that offers a four-quadrant output that incorporates remote (4-wire) sense as well as external guarding. With its high measurement resolution integrated guarding, the PXI-4132 is ideal for high-accuracy leakage measurements on integrated circuits, discrete components, PCBs, and cables. You can also perform high-speed I-V measurements on a variety of components including diodes and organic LEDs using the onboard hardware sequencing engine. In addition, you can synchronize multiple PXI-4132 modules using the PXI backplane to provide high-speed I-V measurements on transistors and more complex devices.
-
Product
High-Speed Precision SMU (100 FA, 60 V, 1 MSa/s)
PZ2120A
-
The Keysight PZ2120A is a cost-effective, high-speed precision source / measure unit (SMU) featuring best-in-class narrow pulse width, fast Digitizer Mode, and seamless current measurement ranging. It enables narrow-pulsed measurements and fast dynamic measurements with a wide dynamic range for a wide range of emerging applications such as vertical-cavity surface-emitting laser (VCSEL) optical devices and integrated circuit (IC) testing. In addition, its low measurement noise performance enables measurements with shorter aperture times, and its seamless current measurement ranging function enables a wide dynamic range and eliminates range change time, which improves test throughput.
-
Product
PXIe Precision Source/Measure Unit, 15 MSa/s, 100 FA, 60 V, 3.5 A DC/10.5 A Pulse
M9603A
-
The Keysight M9603A is a PXIe precision SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
-
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
Product
PXI Source Measure Unit
-
PXI Source Measure Units (SMUs) combine high-precision source and measure capability with features designed to reduce test time and increase flexibility. These features include high channel density for building parallel SMU test systems, deterministic hardware sequencing for minimizing software overhead, and high-speed update and sample rates for quickly changing setpoints and acquiring data. Additionally, the flexible sampling rate and streaming capability of PXI SMUs allows you to use the instrument as a digitizer to capture transient behavior, and the digital control loop gives you the ability to adjust the transient response of the instrument. The ability to change the transient behavior of the SMU, called SourceAdapt, reduces SMU settling time and minimizes overshoot and oscillations, even with highly capacitive loads.
-
Product
Precision Source / Measure Unit (2 Ch, 10 FA)
B2912B
-
The Keysight B2912B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-01
-
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.





























