Product
Versatile RF Network Analyzers for LF and MF
TE3000-series
-
The TE3000-series of RF vector network analyzers have full vector measurement capability, and accurately resolves the resistive, capacitive and inductive components of a load. The user can display the vector impedance plus a range of related parameters including SWR, reflection coefficient, return loss and R-L-C equivalent circuit.
-
Product
Antenna Analyzer
-
Measuring antenna SWR ratio with graphic display in a selected frequency range.Measuring antenna Impedance ( Z = R + j X )Measuring antenna resistance RMeasuring antenna reactance X, all the above with graphic display in a selected frequency range.Quick search for antenna resonance frequencyVery suitable for antenna measurement and adjustment.Portable and small size.Easy and intuitive operation
-
Product
Programmable Step Attenuator, DC to 26.5 GHz, 0 to 11 dB, 1 dB steps
84904K
Attenuator
The Keysight 84904K programmable step attenuator offers coaxial measurements to 26.5 GHz in a compact, rugged design. It offers repeatability of better than 0.03 dB, excellent life (greater than 5 million switching cycles per section) and attenuator range of 0 to 11 dB in 1-dB steps. This latest design evolution sets new standards for size and performance. High attenuation accuracy and low SWR are achieved through the use of miniature thin-film attenuation cards composed of high-stability tantalum nitride film of saphire substrate. Insertion loss is outstanding, with less than 2 dB of loss at 26.5 GHz. The compact size of the unit, 35% smaller than the Keysight 8495/7 (26.5 GHz) family, allows for easy integration into instruments and ATE systems.
-
Product
Manual Step Attenuator, DC to 4 GHz, 0 to 11 dB, 1 dB steps
8494A
Attenuator
The Keysight 8494A, dc to 4 GHz manual step attenuator, offers exceptional repeatability and reliability. Attenuation is provided in 1 dB steps from 0 to 11 dB. Precision gold-plated leaf springs ensure long-life (over 5 million cycles) and very high attenuator repeatability (typically 0.01 dB). To improve measurement accuracy, NIST traceable data (SWR and attenuation) is available as Option UK6. Custom step attenuator/switch combinations are possible. The Keysight 11716A/B/C interconnect kits provide quick connection of Keysight 8494/5/6/7 1 dB and 10 dB step attenuators in series for greater dynamic range with 1 dB steps.
-
Product
PXI Hybrid Coaxial Switch: DC to 40 GHz, Dual Transfer
M9156CH40
Switch Module
The Keysight M9156CH40 PXI hybrid dual transfer switch module provides an exceptional 0.03 dB insertion loss repeatability, high isolation, low SWR with a long operating life up to 10 million cycles.
-
Product
SWR / Power Meters
SX40C
-
Frequency range:144 to 470MHz. Power display range:15W 150W. Accuracy at full scale:10%AT.FS. Minimum power at SWR measurement:3W
-
Product
Coaxial Fixed Attenuator, DC to 26.5 GHz
8493C
Attenuator
The Keysight 8493C coaxial fixed attenuator provides precision attenuation, flat frequency response, low SWR over broad frequency range at a low price. The attenuator has APC-3.5 connectors and is available in nominal attenuations of 3 dB and 6 dB, also 10 dB increments from 10 dB to 40 dB.This attenuator is swept-frequency tested to ensure it meets specifications at all frequencies. Calibration points are provided on a nameplate chart attached to each unit.
-
Product
Diode Power Sensor
8487D
Power Sensor
Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 50 MHz to 50 GHzDiode power sensing element
-
Product
Waveguide Power Sensor
R8486D
Power Sensor
Excellent SWR for reducing mismatch uncertainty50 MHz calibration port Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 26.5 GHz to 40 GHz Diode power sensing element
-
Product
E-Series Average Power Sensor
E9300B
Power Sensor
Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm Frequency range 10 MHz to 18 GHzLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
Vector Network Analyzers
-
The VIA Bravo is a handheld Vector Impedance Analyzer for measuring the impedance and resonant frequencies of circuits and antennas. The VIA Bravo has the capability of providing accurate measurements and sweep displays of impedance, reactance, resistance, phase angle, return loss and SWR. The VIA Bravo’s testing functionality, combined with its 100 kHz to 200 MHz frequency range, make it a versatile tool for many service applications including areas such as MRI, wireless telemetry, 2-way radio, aviation, and Radio Frequency Identification (RFID).
-
Product
Manual Step Attenuator, DC to 18 GHz; 0 to 70 dB; 10 dB steps
8495B
Attenuator
The Keysight 8495B dc to 18 GHz manual step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 10 dB steps from 0 to 70 dB. Precision gold-plated leaf springs ensure long life (over 5 million cycles) and very high attenuator repeatability (typically 0.01 dB). To improve measurement accuracy, NIST traceable data (SWR and attenuation) is available as Option UK6. Custom step attenuator/switch combinations are possible. The Keysight 11716A/B/C interconnect kits provide quick connection of Keysight 8494/5/6/7 1 dB and 10 dB step attenuators in series for greater dynamic range with 1 dB steps.
-
Product
SWR Meters
-
Field Strength FunctionAvailable as a stand-alone meter which operates on 8 AA batteries or as a 140-525 Analyzer Kit with Belt Case, AC Adapter, Analyst Director software and serial cable
-
Product
Programmable Step Attenuator, DC to 40 GHz, 0 to 90 dB, 10 dB Steps
84906L
Attenuator
The Keysight 84906L programmable step attenuator offers coaxial measurements to 40 GHz in a compact, rugged design. It offers repeatability of better than 0.03 dB, excellent life greater than 5 million switching cycles per section) and an attenuation range of 0 to 90 dB in 10-dB steps. This latest design evolution sets new standards for size and performance. High attenuation accuracy and low SWR are achieved through the use of miniature thin-film attenuation cards composed of high-stability tantalum nitride film of saphire substrate. Insertion loss is outstanding, with with only 2.4 dB of loss at 40 GHz. The compact size of the unit, 35% smaller than the Keysight 8495/7 (26.5 GHz) family, allows for easy integration into instruments and ATE systems.
-
Product
FET Solid State Switch, 300 kHz to 8 GHz, SPDT
U9397A
Solid-State Relay
The Keysight U9397A solid state switch maximizes your frequency range from 300 kHz up to 8 GHz, offering excellent performance with high isolation, low SWR and fast switching speed. Applications include instrumentation, communications, radar, and many other test systems that require high speed RF and microwave SPDT switching.
-
Product
Programmable Step Attenuator, DC to 4 GHz, 0 to 11 dB, 1 dB steps
8494G
Attenuator
The Keysight 8494G dc to 4 GHz programmable step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 1 dB steps from 0 to 11 dB. Precision gold-plated leaf springs ensure long-life (over 5 million cycles) and very high attenuator repeatability (typically 0.01 dB). To improve measurement accuracy, NIST traceable data (SWR and attenuation) is available as Option UK6. A maximum switching time of 20 ms (including contact settling) speeds automatic testing. Custom step attenuator/switch combinations are possible. The Keysight 11716A/B/C interconnect kits provide quick connection of Keysight 8494/5/6/7 1 dB and 10 dB step attenuators in series for greater dynamic range with 1 dB steps.
-
Product
E-Series Average Power Sensor
E9300H
Power Sensor
Measure the average power of all modulation formats Wide dynamic range power measurements from -50 dBm to +30 dBm Frequency range 10 MHz to 18 GHzLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
E-Series Average Power Sensor
E9301A
Power Sensor
Measure the average power of all modulation formats Wide dynamic range (-60 dBm to +20 dBm) and frequency range 10 MHz to 6 GHzHigh maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors linearity and temperative compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the Keysight E4416A)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
Antenna Tuner
DU-3000T/DU-3000TB
-
The DU 3000T and DU3000TB tuners optimize the performance of your antenna and transmitter or SWL receiver by providing adjustable impedance matching. The DU-3000 series also measure the Power and Standing Wave Ratio (SWR), which allows you to tune the indicated SWR to the lowest possible value for the selected transmitfrequency.
-
Product
ANTENNA ANALYZER
MFJ-213
-
MFJ-213 covers 1-60 MHz with digital precision. It also displays SWR, complex impedance, and impedance magnitude simultaneously all on the same easy-to-read LCD screen.
-
Product
Wide Dynamic Range Power Sensor, E-Series
E4412A
Power Sensor
Fast measurement speed, up to 400 readings per second with the E4416AWide dynamic range (-70 dBm to +20 dBm)Calibration factors, linearity ana temperature compensations data stored in EEPROM Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to NIST Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
Noise Bridge, RF 1 MHz to 100 MHz
MFJ-202B
-
Quickly adjust almost any antenna for maximum performance, 1 to 100 MHz. Lengthen or shorten your antenna for minimum SWR. Measure resonant frequency, feedpoint resistance and reactance. Works with any receiver or transceiver. Hand-calibrated resistance scale, expanded capacitance range and exclusive built-in range extender.