Showing results: 6886 - 6900 of 8146 items found.
-
NI
PXI instrumentation ensures complete and accurate test coverage with a modular architecture mounted in ultra-reliable PXI chassis.TestStand and LabVIEW software provide rapid development of complex test steps and sequences. PXI systems conserve floorspace because of their small, light form factor. Order them preassembled and installed using NI ATE Core Configurations.SystemLink™ software deploys updates and democratizes data insights to optimize operational efficiency.
-
45-542-001 -
Pickering Interfaces Ltd.
The 6U PXIMatrix Module 45-542 is a very high density electro-mechanical relay matrix available in 132x8 format with 1 pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. The matrix is constructed using high reliability 2A electro-mechanical relays, offering >10e8 operations (under low power loads) to give maximum switching confidence with long life and stable contact resistance.
-
40-675A-002-10/16 -
Pickering Interfaces Ltd.
The 40-675A-002-10/16 is a 10-channel, 16-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675A-002-24/8 -
Pickering Interfaces Ltd.
The 40-675A-002-24/8 is a 24-channel, 8-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675A-002-5/32 -
Pickering Interfaces Ltd.
The 40-675A-002-5/32 is a 5-channel, 32-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675A-002-49/4 -
Pickering Interfaces Ltd.
The 40-675A-002-49/4 is a 49-channel, 4-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675A-002-99/2 -
Pickering Interfaces Ltd.
The 40-675A-002-99/2 is a 99-channel, 2-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675A-002-198/1 -
Pickering Interfaces Ltd.
The 40-675A-002-198/1 is a 198-channel, 1-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Model 58810 -
Pentek, Inc.
- Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Supports Xilinx Kintex Ultrascale FPGAs- Front panel digital I/O can be used as a status and control or data interface- PCI Express (Gen. 1, 2 & 3) interface up to x8- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Ruggedized and conduction-cooled versions available
-
Model 57810 -
Pentek, Inc.
- Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Supports Xilinx Kintex Ultrascale FPGAs- Front panel digital I/O can be used as a status and control or data interface- PCI Express (Gen. 1, 2 & 3) interface up to x8- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Ruggedized and conduction-cooled versions available
-
Type 131 -
Datum Electronics, Ltd.
The Type Load Cell 131 Amplifier is designed to interface to a full bridge strain gauge based load cell or similar sensor allowing the user to use the data from the load cell in a more efficient and productive way.The Type 131 Load Cell Amplifier is designed to interface to a full bridge strain gauge based load cell or similar sensor. It can be calibrated to provide a 4-20mA output for a fixed load range from the sensor.
-
AQW Series -
Chuan Sheng Electronics Co., Ltd.
AQW series was designed for air quality measure, such as PM2.5, Ch20, CO2, temperature and humidity. Use high-precision sensor to ensure long-term stability and reliability of the instrument.Panel with large LCD display, easy to read the measuring value.And also have 4 LED indicator to indicate air quality status and device running.AQW series communication port is WiFi, it’s convenient for data collect, support Modbus TCP protocol, and others cloud protocol.
-
40-675-002-99/2 -
Pickering Interfaces Ltd.
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675-002-198/1 -
Pickering Interfaces Ltd.
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675-002-49/4 -
Pickering Interfaces Ltd.
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.