Shunts
An Instrument Shunt is a resistor connected in parallel with a measuring device to move the current range beyond a particular value for which the instrument is capable of measuring directly.
See Also: Current Shunts
-
Product
Digital Power Meter, 30A
66205
-
Chroma Systems Solutions, Inc.
Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface
-
Product
AC and DC Non Inductive Current Shunt
Series A co-axial shunt and Option 02F/B shunt
-
Use with wattmeters, DMMs and power analyzers to extend current measurement ranges. Use with phase angle meters to enable phase angle measurements between voltage and current. Ultra low phase shift
-
Product
Ultra High Power Precision Shunt Resistor
UHPS
-
*Max. current limit 707A*Excellent short term stability*Low temperature coefficient of resistance (T.C.R.)*High current sensing & reference resistors in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies
-
Product
DC-to-250MHz 1:100 Oscilloscope Probe Kit (HP-9258)
PRB-HP-9258
-
The Oscilloscope Probe 1:100 - HP-9258 is a low-input capacitance high voltage 1:100 oscilloscope probe with a bandwidth of 250 MHz designed and calibrated for use on scopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with oscilloscopes having an input capacitance of 10 - 35 pF.
-
Product
High-Frequency Probe, 300 kHz to 3 GHz
85024A
ICT/FCT Probe
85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of resistance permits high frequency probing without adversely loading the circuit under test. Excellent frequency response and unity gain guarantee high accuracy in swept measurements with this probe. High probe sensitivity and low distortion levels allow measurements to be made while taking advantage of the full dynamic range of RF analyzers.
-
Product
DC-to-250MHz, X1/x10 Probe Kit (HP-3250i), Isolated BNC
PRB-HP-3250i
-
Oscilloscope Probe 1:1-1:10 - HP-3250i250 MHz bandwidth, rated 600 V.The Oscilloscope Probe 1:1-1:10 - HP-3250i is a 1:1-1:10 selectable passive high impedance oscilloscope probe with 250 MHz bandwidth (1:10) designed and calibrated for use on oscilloscopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with an oscilloscope having an input capacitance of 10 to 30 pF.
-
Product
Connectors, Jumper - Black
INT-10901
-
Jumper for 0.1" (2.54mm) spaced headers. These are also known as a 'shunt'. These mate with the 0.1" square-pin headers and are the 'open' frame style. RoHS compliant.
-
Product
ABex Current Sense Module for Six Channel UUT Supply Monitoring
ABex TM-406 Current Sense
-
The ABex TM-406 is a six-channel shunt current measurement extension. It’s designed to work in combination with the Konrad ABex TM-501 and PXI-501.Each of the six shunt current measurement units have a passive measurement shunt, an overcurrent protection, a sense bridge relay and the possibility to route the quiescence current to an ABex measurement device TM-501 with PXI-501.In addition, the ABex TM-406 features 8 isolated digital outputs (IDOs), and 12 measurement inputs, which can be routed to the analog bus.
-
Product
Shunt: ACQ-200
BWR
-
*5 watts*Resistance values down to 0.0003 ohms*Special tight tolerance are available on request
-
Product
Shunt Reactors
-
ENTES Shunt Reactors are high quality devices which are designed to meet the inductive load demands.
-
Product
Load Cell Amplifier Signal Conditioner with DB9 Connectors
MODEL LCA-9PC
-
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
Product
LV Iron Core Shunt Reactors
-
Iron core Shunt Reactors act as an absorber of reactive power to increase energy efficiency of the power system. Shunt Reactors are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. Shunt Reactors can be directly connected to the power line or to a tertiary winding of a three-winding power or distribution transformer.
-
Product
High Power Shunt Resistors
CS227
-
The CS227 is a metal foil, SOT227 resistor designed to give a high current capability. The metal foil element is situated on an insulated heatsink composed of plated copper. This assembly is then mounted into a durable plastic housing and sealed with high temperature epoxy.
-
Product
Precision High Current Resistors/Shunts
-
Measurements International Ltd.
The precision high current shunts are a series of High Current Resistors ranging from 1 A to 3000 A with optional air moving fans and resistance values from ohms to micro-ohm.
-
Product
Rad-Hard Analog ICs
-
ST's wide range of rad-hard QML-V qualified analog ICs covers analog-to-digital converters (ADC) and digital-to-analog converters (DAC) for telemetry, instrumentation and imaging applications. Our portfolio also includes rad-hard op amps, high-speed differential amplifiers up to 1 GHz, shunt voltage references and comparators to ensure a complete solution for signal conditioning, referencing and data conversion.
-
Product
Precision AC/DC Active Current Shunt
2575A
-
A versatile, powerful calibration tool, the 2575A Precision AC-DC Active Current Shunt measures both AC/DC current and works as a standard for low-level resistance calibration requirements.
-
Product
DC Power Analyzer, Modular, 600 W, 4 Slots
N6705C
-
The N6705C DC Power Analyzer provides unrivaled productivity gains for sourcing and measuring DC voltage and current into the DUT by integrating up to 4 advanced power supplies with DMM, Scope, Arb, and Data Logger features. The N6705C eliminates the need to gather multiple pieces of equipment and create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. The DC Power Analyzer also eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all functions and measurements are available at the front panel. For even greater control and analysis functions, the DC Power Analyzer can be used with the 14585A Control and Analysis Software. When automated bench setups are required, the N6705C is fully programmable over GPIB, USB, LAN and is LXI Compliant. 14585A Control and Analysis Software
-
Product
Single Phase 2 Circuit Energy Meter Test Bench Type KP-S1000-B
-
Bofa Instrument & Equipment Co., Ltd
Single phase 2-circuit energy meter test bench type KP-S1000-B, is a new generation, high precision energy meter calibration equipment. It is especially designed for testing 2-circuit energy meter (shunt circuit and CT circuit), open or closed test link (I-P link) both. It is an ideal testing equipment for mass production of 2-circuit energy meter in meter factory. All the testing procedures can be automatically operated by PC or by Keyboard manually.
-
Product
Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module
MODEL TMO-2A
-
The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
Product
PXIe-4330, 25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module
781346-01
Analog Input Module
25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4330 is a simultaneous input module that provides integrated data acquisition and signal conditioning for bridge-based sensors. The PXIe‑4330 includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4330 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4330 provides remote sensing, internal bridge completion, and shunt calibration options per channel.
-
Product
L Terminal Shunt Resistor
LT
-
LT shunts are highly accurate manganin resistance D.C. shunts. These shunts are designed for standard current measurement of electric equipment.
-
Product
Resistance Calibration
-
Process Instruments maintains fractional part-per-million accuracy with a state of the art resistance calibration facility. Specialized services include precision resistor manufacture, resistor and shunt repair, characterization of alpha and beta temperature coefficients and the determination of barometric effects on resistance values.
-
Product
NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783311-01
Voltage Input Module
±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.
-
Product
Turbine Flowmeters
-
Titan’s small turbine flowmeter range use a radial flow principle based on the Pelton wheel technique. This well proven method is the ideal way of measuring low rates of flow of low viscosity liquids. For these mini flowmeters, a jet of fluid is directed at a turbine that is mounted on robust low friction sapphire bearings. The geometry of the turbine and the fluid chamber ensures that the rotational speed of the rotor is proportional to the flow rate through the device. The use of this radial arrangement allows more energy to be imparted into the turbine, so the bearing drag is far less important. Furthermore, because more energy is available the bearings themselves can be a lot stronger so increasing the life of the flowmeter. For larger flows, some of the liquid can bypass the turbine chamber, which then behaves as a “shunt” to the metered fluid. Accuracy is still maintained and the output remains linear.
-
Product
Precision Shunt Resistors
PBV, PBH
-
High power low resistance values and high precision. Low temperature coefficient. Excellent load life stability. Excellent short time over load. Ideal for current sensing applications.
-
Product
FD-11637, 8-Channel Strain/Bridge Input Device for FieldDAQ
785641-01
Strain/Bridge Input Module
8-Channel Strain/Bridge Input Device for FieldDAQ - The FD-11637 can measure eight channels and has built-in bridge completion and voltage excitation to support for quarter-, half-, and full-bridge sensors. It also features anti-alias filtering, offset nulling, and shunt calibration to reduce the effect of noise and improve measurement accuracy. The FD-11637 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 grm vibration. The FD-11637 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11637 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11637 is ideal for test cell and outdoor environments.
-
Product
Multiphase Power Analyzer
2800 Series
-
The Valhalla Scientific 2800 High-Precision Power Analyzer is available in 1-, 2-, 3-, 4-, 5-, or 6-phase versions. All voltage inputs 0.3V up to 1500V peak and all current inputs 1.5mA up to 1A; 15mA up to 5A; 1A up to 40A; and shunt inputs 60mV up to 6V are potentially free and exhibit low noise, high common mode suppression, excellent DC-stability, wide frequency range (DC-2MHz) and very low self-heating on current inputs.There is no need to fiddle with DC-compensation, or changing current plugging. All is built into the input sections of the power analyzer, ready for measurements. It is simple to use, your intuition will guide you to operate the Power Analyzer touch screen correctly.
-
Product
Microprocessor Based Indicator
-
Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design Provides Excitation to Transducers or Sensors Accept DC mV/V, V, mA Signal Proportional Analog Output V or mA Easy to Program using 4 ButtonsFront Panel Shunt Calibration User Programmable High & Low Set Point Standard No-Output or Relay Output Optional 8-Step Output, RS232, or BCD Output Available
-
Product
Ungrouped
-
Weshine Electric Manufacturing Co., Ltd
The instrument can measure single capacitor of single phase or three-phase shunt capacitor bank without removing wires.2. The instrument has the functions of inductance, resistance and current measurement.3. The instrument has two power supply modes: External AC220 V and built-in lithium battery meet various application scenarios.
-
Product
68 Pin Breakout Interface
VSI-Breakout-68
-
The VSI-Breakout-68 is a very useful tool in debugging signals or software in a system. It allows unlimited access to signals within the cabling that might otherwise be difficult to access. The board gives test points at each side of the connector and jumper with a easy to use tabbed shunt to allow for easy disconnection of any particular signal between the connectors. The jumpers also give an opportunity to inject a signal regardless of what signal was originally being driven.