Reactive Load Banks
Provide both lagging and leading power factor loads.
See Also: Load Banks, AC Load Banks, DC Load Banks, Inductive Load Banks, Resistive Load Banks
-
product
PXI MUX 1 Bank of 64 Channel 1 Pole
40-610-021-1/64/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
Power ICs - Smart Load Switches
Combining multiple functions in a single IC, Vishay smart load switches eliminate the need for external circuitry . A simplified GPIO interface allows for power distribution and sequencing of multiple sub-systems. Slew-rate-control devices provide a controlled supply ramp to reduce inrush current, while fault protection and isolation switches increase robustness with reverse current, overtemperature, current limiting, and short circuit protection features. The ICs offer quick output discharge and small footprints, while their integrated design saves PCB space compared to discrete solutions, reduces BOM counts, and lowers manufacturing costs.
-
product
Smart Load Manager
Nippen Electrical Instruments Co.
This is flush mounting micro controller based instrument with multilayer PCB having SMT components offering accuracy and reliability along with reduction in EMI and EMC interference. These are specially designed to simultaneously measure, display and communicate several electrical parameters. This meter is an Ideal data source for effective Energy management, SCADA, PLC, BMS etc to measure as many as 36 parameters on 23 display pages, which are true RMS. The readings are displayed on 3 line bright Red 7 segment LED, each row/ line having 4 14.2mm high LEDS.
-
product
PowerSync Programmable Loads (PSL-3424, PSL-3000)
The PSL-3424 is Sifos’ newest member to the PSA-3000 family of PSE test instruments. It uniquely offers capability to continuously load up to 24 4-Pair, 100 watt capable PSE ports simultaneously. It also introduces new testing features not previously available in the PSL-3000 Programmable Load.
-
product
Subsea Shackle Load Cell
SUBS-3.0
The Subsea Shackle Load Cell has been designed to measure loads in a subsea environment. DLM’s subsea shackles are suited to fit leading industry Crosby and GN shackles.
-
product
PXI 18 Bank, 3 Channel, 1 Pole Multiplexer
40-617-021
The 40-617 18-Bank, 3-Channel, 1-Pole Multiplexer Module forms part of the System 40 PXI Programmable Switching system. The Module consists of 18 electrically isolated banks of multiplexers controlled by a PXI/PCI interface. Each bank is a 1 to 3 multiplexer and operates with break-before-make action when a new channel is selected. Any Individual multiplexer bank can have a channel set by itself, alternatively, multiple banks can have channels selected simultaneously. Inter-bank linking relays allow multiplexer size to be increased in multiples of 3 by joining the common terminals of adjacent banks. Closing one linking switch produces a 6 channel multiplexer, closing all linking switches produces an 54 channel multiplexer.
-
product
Carpet Dynamic Loading Tester
TF610
TESTEX Testing Equipment Systems Ltd.
Carpet Dynamic Loading Tester, by simulating walking to determine the effects to two of the main actions of walking: compression, and the shearing effect at the edge of the shoe.
-
product
Modular DC Electronic Load
63600
Chroma Systems Solutions, Inc.
Chroma’s 63600 Modular DC Electronic Load is designed for testing multi-output AC/DC power supplies, DC/DC converters, chargers, batteries, adapters, and power electronic components. They are excellent for use in research, development, production, and incoming inspection applications. The 63600’s state-of-the-art design uses DSP technology to simulate non-linear loads using an unique CZ operation mode allowing realistic loading behavior.
-
product
Loading Rheostats (Resistive Load)
Supreme Instrument Laboratories
Loading Rheostat is a device specially designed to meet the requirements of Engineering Laboratories, Electrical Test Rooms and Industries. It is used for loading transformers, power generators, supply mains etc. neatly and efficiently. It can also be used advantageously for regulating current and adjusting voltage besides its application for calibrating meters and thus eliminating the need for graded rheostats.
-
product
Dry Dielectric RF Coaxial Loads
These 50-Ohm RF Load Resistors are light weight, dry coaxial loads that can be used in any position. All power ratings are for continuous operation. However, data is available for special applications and pulsed power conditions. Any of our Quick Match connectors can be used on these loads. Should you desire a connector other than the one included, it should be specified when ordering.
-
product
Miniature S-Beam Load Cell
500 Series
The Miniature S-Beam Load Cell is a bi-directional Aluminium strain gage based transducer with high performance and builtin temperature compensation. This design provides better than ±0.1% (full scale) non-linearity and includes overload protection in both tension and compression directions. Options include IEEE1451.4 TEDS capability.
-
product
Load Cell Measurement Interface
LCIC-1106a
Industrial Measurement Systems Ltd.
Any application related to weighing or measuring forces is now available in your PC...Stand-alone microcomputer-based interface card requires no other interfacing accessories. Simply connect th
-
product
Portable Three-Phase Phantom Load
EE-120A-3 + EE-500V-3
The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. The generated values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
product
Signature Compression Only Load Button Load Cells
SLB SERIES
The SLB Series Subminiature load cells (Load Buttons) are offered for compression only applications where space is limited. The matching surface must be flat for ultimate accuracy. The loading diameter is slightly convex for accurate load distribution. These sensors are manufactured from heat treated 17-4ph stainless steel, and the sensing element incorporates bonded foil strain gages of the highest quality. They are sealed for protection against most industrial environments.
-
product
Digital LOOP/PSC/LOAD Tester
2811 LP
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Displays and sound warning if external voltage present.● Displays mains voltage, scroll trough menus.● Checks wiring integrity (LEDs and display).● Single button operation.● Auto-off/auto-ranging.● Combined prospective short circuit current, PSC and LOOP tester.● Built-in carry case, test leads in separate pouch.● Loop test for L-E and L-N and PSC.● Voltage test L-N and L-E.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for special orders.● 60Hz available on request.
-
product
High Speed DC Electronic Load
6330A series
The 6330A family offers 8 types of modular loads with power ranging from 30 watts to 1200 watts, current from 0.5mA to 240A, and voltage measurement from 0.5mV to 500V. Each load is isolated and floating, programmable in dual current range and measuring voltage range, and capable of synchronizing with other modules for control operating. The load can be operated in constant current, constant voltage, and constant resistance. With Synchronic parallel control capability, 6330A series loads allow users to parallel and synchronize more than one load together from an internal loading control signal. This feature provides synchronic dynamic loading test for multi-output power and high power test solution. Real time measurement of voltage, current, is integrated into each 6330A load module using a 16-bit precision measurement circuit. The user can perform on line voltage measurement and adjustment, or simulate short circuit test using the simple keypad on the front panel.
-
product
48V / 300 Amp Load
BD18-48P
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 48V and 50V, (24 or 25 cells at 2V each), battery systems and is extremely cost effective.
-
product
Bending Beam Load Cell
EST-7
Technopark Automation & Control
The EST-7 is a Bending Beam Load Cell suitable for use on lower capacity weigh hoppers, filling machines, packaging machines and conveyor belt scales. This load cell is available in capacities from 10 kg to 200 kg.
-
product
Robotic Sample Loading Systems
Below you can see examples of two systems using our robotic sample loading system. Many other automated microscopy systems are possible using our components.
-
product
Filters & Switch Filter Banks
PMI offers the highest quality filters, switch filter banks, filter assemblies, diplexers, multiplexers for industrial and military applications in the frequency range of DC to 40 GHz. All PMI’s Switch Filter Banks use PMI’s proprietary Solid-state Switch designs, which offer high speed and improved performance. While there are many standard models, PMI can design and build to meet your specifications.
-
product
Low Profile Compression Only Load Button Load Cell with Mounting Holes
LBC SERIES
The LBC Series (Load Button) load cells are offered for compression only applications where space is limited. The matching surface must be flat and at least the diameter of (D1). The loading diameter (D2) is slightly convex for accurate load distribution. Counter bored mounting holes are provided for fastening down from the top. These sensors are manufactured from heat treated 17-4ph stainless steel and sealed for use in most industrial environments.
-
product
AC & DC Electronic Loads
The Adaptive Power Systems Electronic Loads cover a wide range of power levels, voltage and current profiles and feature sets.Supported voltages range up to 1250Vdc or 350Vrms AC. From bench to system and DC or AC requirements, we can more than likely offer you the optimal programmable load to meet your needs.
-
product
DC Electronic Loads
Next Generation Instrumental (Shanghai) T&C Tech. Co., Ltd.
NGI DC Electronic Loads
-
product
Load Cells
Flintec load cells are highly accurate and built to last. We pride ourselves on the quality of our products and the service we provide.Our sensors are available globally. If your application requires a Custom Solution, our expert engineers can help.
-
product
PXI MUX 4 Banks of 32 Channel 1 Pole
40-610-022-4/32/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI 1 Bank of 80 Channel 2 Pole MUX
40-615-022-1/80/2
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
DC Loads
Becker Nachrichtentechnik GmbH
Becker Nachrichtentechnik offers wideband multichannel DC decouplers for antenna diagnostic applications. Due its high bandwidth the device is suitable for all broadcast, cellular and Wi-Fi standards.




























