Reactive Load Banks
Provide both lagging and leading power factor loads.
See Also: Load Banks, AC Load Banks, DC Load Banks, Inductive Load Banks, Resistive Load Banks
-
product
Resistive Load Banks
R Series
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.
-
product
Dc Load Bank
Highly reliable and durable new alloy resistor is used for the JUNXY DC load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable.
-
product
SMART Constant Current DC Load Banks
SLB-Series
SMART Constant Current DC Load Banks are designed for acceptance testing, discharge testing, battery capacity testing, battery maintenance, engineering examination and other testing for DC power with load. The SMART technology allows a constant current discharge without the need for manual adjustment of current during the discharge test. Our SLB-Series load banks are portable, durable, economic, safe, easy-to-use and come complete with our DataView software, providing the user with a complete data management and analysis program.
-
product
Load Board
cPCI 6U
Load boards are essential in keeping any system in top running shape. As a full-system provider, Hartmann strives to not only provide the systems you need, but the supporting hardware as well.
-
product
Inductive Load Banks
L-Series
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
product
AC Load Banks
XL500-XL600 Series
Mosebach Manufacturing Company
The XL500-XL600 Series load banks offer you a continuous load at various voltages in a compact, lightweight enclosure.
-
product
Load Module for SLSC
Bloomy's 8-Channel Load Module provides isolated current and voltage measurements for eight on-board 5W loads or for eight off-board 120W loads. With built-in switching for calibration and fault injection, the module provides unsurpassed capability for Mil/Aero applications. The module also provides switching and connections to allow switching between a real load (e.g., actuator, valve, etc.) and the simulated load.
-
product
AC Load Bank
AC-LB-Series
Eagle Eye AC Load Banks are commonly used for testing generator sets, UPS units, aircraft power inverters and other government and military AC power sources. The Eagle Eye AC LB-Series is the smallest in the industry and offers unmatched durability in even the harshest testing environments. Eagle Eye offers several standard models as well as custom AC Load Banks.
-
product
AC Load Banks
Guangdong EMAX Electrical Co., Ltd.
We offer AC load banks in a variety of capacities and any voltage combination, with custom models including resistive, inductive, capacitive or resistive/reactive combination loads, all tailored to meet any load testing requirement.
-
product
Specialty/Custom Load Banks
XLHV Medium Voltage Series
Mosebach Manufacturing Company
The XLHV range offers you a continuous load at higher voltages in an outdoor rated enclosure. These can be for AC or DC load banks up to 15kV.
-
product
AC Load Bank (Resistive/Reactive)
K-1000 Resistive/Reactive
Kongter Test & Measurement Co., Limited
Resistive/reactive load banks are great choices for testing turbines, switchgear, rotary UPS, generators and UPS systems. They can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others. A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage.
-
product
Three Phase Load Bank
REOLOAD 310
A three phase load bank rated for 48kW, with fan cooling. The front panel layout includes a switch panel for configuring the separate resistor modules to give the required resistance and current range. There are also digital panel meters for displaying the phase voltages and currents. An interface for PLC control is also provided.
-
product
Extended Battery Banks
Falcon Electric’s extended battery banks provide extra battery runtimes from minutes to hours with our SSG and SSG-RP online industrial UPS systems. The rackmount banks are easily daisy-chained with DC plug-and-play connectors. Simply determine your application requirements and select one of these battery bank options.
-
product
Resistive & Capacitive AC Load Bank
RCD
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
product
Capacitor Bank Protection
Schweitzer Engineering Laboratories, Inc.
Capacitor bank protection products and systems provide complete primary and backup protection for all types of capacitor configurations.
-
product
Battery Load Bank
K-3980
Kongter Test & Measurement Co., Limited
Kongter offers a series of customized DC load banks with many different models for constant current battery discharge test and battery capacity test. They cover a wide voltage range from 12V to 480V nominal voltages with current up to 600A. They are widely applied in various industries. With its optional battery Data Acquisition Case (DAC), discharge values of EACH cell could be monitored in battery load bank and PC software simultaneously by using Kongter’s data view software.
-
product
AC Load Banks
XL1500 Series
Mosebach Manufacturing Company
The XL1500 Series of resistive load banks are designed for testing power supplies up to 1500kW of various voltages.
-
product
Load Cells
For use in harsh environments, our Models T66 (bending beam),T85 and T85-T(shear beams)are manufactured fromstainless steel, fully welded and hermetically sealed to provide total environmental protection (IP68 and IP69K). The T85-Tmodel has a blind loading hole, ideal for use in platform scales.
-
product
AC Load Banks
K-1000 Series
Kongter Test & Measurement Co., Limited
Load bank testing is vital to replicate and verify the operation of critical backup power systems such as diesel generators and uninterruptible power supplies (UPS). Kongter offers a wide range of customer-tailored AC load banks that excel in a range of load test applications and environments.
-
product
Load Logger
LL-230
AMETEK LoadLoggers* and LoadProfilers are non-invasive digital recording loggers for gathering data on distribution loads and power quality. Whether the data is from a load site or direct from the distribution system, the AMETEK Load Management products are easy to install, operate and analyze.
-
product
Reactive Energy Regulator
MASTER
Lifasa - International Capacitors, SA
It measures the reactive power needs of an installation and gives the corresponding capacitor connection and disconnection orders to keep the cos φ preset. At the same time it allows to measure the main parameters of an installation (voltage, current, harmonics, active power, reactive power, etc.), by using 1 or 3 current measurement transformers.
-
product
AC Load Banks
X100L-600 Series
Mosebach Manufacturing Company
Mosebach’s X100L-600 is the smallest load bank of 100 kW with 5 kW resolution. Offers a continuous load at 600/480/240/208 volts. Great for most generator testing. And lightweight – only 64 lbs!
-
product
Terminations & Loads
We have more than 40,000 rf & microwave coaxial terminations in stock we can ship today. We offer these Microwave & RF terminations: SMA Terminations, Type N terminations, 7/16 DIN terminations, 2.92mm terminations, 2.4mm terminations, TNC terminations, smp terminations, minismp terminations, 4.1/9.5 minidin terminations. 4.3/10 terminations, ssma terminations, ssmc terminations, and a few Reverse Polarity terminations. Power levels of 0.5-150 watts. RF / Microwave terminations are also known as dummy loads or 50 ohm dummy loads. Our 1.85mm terminations, are rated to 67ghz. We offer 1.0mm terminations good to 110Ghz.
-
product
Battery Load Banks
Kongter Test & Measurement Co., Limited
Kongter offers many different models of battery load units for real capacity test in various industries. With our customized solution, users of different applications will find their exact models as per their needs. With its optional DAC (Data Acquisition Case), you could easily monitor voltage of each cell on PC during battery discharge test.
-
product
Banking, ID & Transport
ST’s secure microcontrollers are designed for a wide range of applications including SDA & DDA banking, identification, transport and Pay TV solutions. From traditional smart cards to innovative wearables and biometric solutions, ST offers a complete portfolio of contact, dual-interface and contactless secure microcontrollers.
-
product
Radiator Mounted Load Banks
RD-Series
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
product
Dummy Load
Dummy load is capable of dissipating four times the legal limit 6 kW for 2 minutes and legal limit 1500 watts key down, forever. It covers the 160 meter to 6 meter bands (actually 1 Mhz-60 MHz continuously). It is a dry dummy load intended for testing amplifiers and station conditions. Two fans on the rear of the unit are automatically turned on when the internal temperature reaches 120°F/49°C . The unit runs off a universal AC supply. Simple to operate and use, the dummy load includes an RF sample output of -60 dBc.