Blackbodies
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
Product
Sodium heat Pipe Blackbody Source
Oberon R Model 426
-
The Oberon R uses a Sodium heat Pipe to ensure an exceptionally low temperature gradient along the furnace core. It is ideal for the realization of Aluminium, Silver or Copper ITS-90 Fixed Points.
-
Product
Proprietary Software
WinFT
-
WinFT is our proprietary software which makes D&P instruments so functional and easy to winft1_largeuse. Based on the Windows operating system, this software provides simple and intuitive control of the instrument. All of the usual File functions are available, as well as controls over instrument settings such as resolution, apodization, zero-fill and number of coadds. Display options enable the user to display interferograms, spectra or both, as well as to adjust plot scales and units. Onboard math processing allows for real-time calculation of ratio, difference, and absorbance, and when using our calibrated hot-cold blackbody calibrators, the ability to measure calibrated radiance. Further, WinFT offers the ability to measure sample temperature in the radiance function by matching a Planck to the calibrated radiance. With the gold diffuse plate, the software can also compute and display absolute emissivity of samples. Our software also enables exporting of data files, now made even easier with our USB and LAN connections. In addition, the software has been designed to be easily run using the keyboard function keys and single letter commands, making the use of a mouse in the field optionalas well as minimizing key strokes when taking measurements in the field.
-
Product
Camera Testing
FLIR
-
CI Systems' FLIR turn-key test stations carry out all the necessary tests to verify and compare the quality of an infrared/thermal camera. The FLIR test systems are based on CI Systems' NIST traceable blackbody radiation sources, collimators and special thermally controlled targets, designed to provide very accurate IR test patterns. All these combine to project standardized targets with known geometry and intensity to the Unit Under Test(UUT).
-
Product
INFRATEST Software
-
INFRATEST is a powerful software for testing visible to IR cameras, goggles and laser rangefinders. Based on video acquisition modules compatible with a wide range of communication protocols, INFRATEST acquires, displays and analyzes the video signal from all types of electro-optical devices. In addition, INFRATEST manages the optical stimuli delivered to the camera through the control of blackbodies and visible/NIR optical sources and their accessories (collimator, target wheel, harmonization modules, etc.).
-
Product
Infrared Thermometer
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
Thermometer which infers temperature from a portion of the thermal radiation sometimes called blackbody radiation emitted by the object being measured.
-
Product
Dual Blackbody Wide FOV
-
Dual blackbody, all reflective background IR target projector is used to characterize WFOV IR sensor systems. It features a broadband, 3 to 14 micron range, reflective IR target technology for the most accurate and stable differential targets, controlled background radiance, a 5º FOV with 36º uniform background.
-
Product
Spherical Blackbody Source
Cyclops Model 878
-
The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for use as a radiation source for infrared thermometers.
-
Product
Standard IR Target Projectors
-
Santa Barbara Infrared’s 14000Zi Series reflective infrared target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies and 300 Series Target Wheels. SBIR also offers a standard athermal target projector with a 5.7° field of view (FOV).
-
Product
Blackbody System
IR-518/301
-
Infrared Systems Development Corp.
The IR-518 Radiation Source provides an accurate, stable source of infrared radiation of known flux and spectral distribution. It can be used as a standard radiation source for the calibration of other laboratory sources, detectors, or other infrared devices requiring calibration against a standard.
-
Product
SpectralLED® Tunable Light Sources
-
The award-winning SpectralLED® family of uniform intensity tunable light sources are designed to deliver unmatched resolution and accuracy. These adjustable wavelength LED light sources also have an operating lifetime and cost of ownership that cannot be duplicated with traditional light sources such as Tungsten-Halogen and Xenon lamps. With a fully spectrally tunable output, all you need is one SpectralLED to generate any arbitrary spectral power distribution, whether it be blackbody, daylight, fluorescent, LED, or something completely unique. By sweeping through individual LED channels, the SpectralLED can even emulate a traditional monochromator light source, with no moving parts and no halogen input illumination.
-
Product
Multi-Spectral Target System
IR-704
-
Infrared Systems Development Corp.
The IR-704 system integrates a Blackbody source, Motorized Aperture wheel, Motorized Filter Wheel, High Speed Shutter and High Speed Filter Shutter. The system was designed as a forced air-cooled Multi-Spectral, Multi-Aperture target system for direct integration with collimator / target projection systems, but can also be used as a direct target system.
-
Product
Infrared Calibration
-
Optical pyrometers can be calibrated from 800 to 2300C using NIST certified ribbon filament lamps and temperatures up to 3500C using a graphite arc furnace. Infrared thermometers can be calibrated from -30C to 2300C utilizing state-of-the-art blackbody sources and transfer standards.
-
Product
Blackbody System
IR-574/301
-
Infrared Systems Development Corp.
The IR-574 Series blackbody reference sources are designed to provide infrared radiation as an ideal blackbody emitter. The output energy from the 2.25" Cavity closely follows the theoretical maximum energy curve described by Max Planck's equation, and allow users to calibrate, align, and measure infrared devices and phenoma of all types.
-
Product
Collimators
STC Series
-
The STC Series Off-axis Newtonian Collimators from Santa Barbara Infrared provide superior performance in a compact, light weight, readily integrated package. These collimators accurately project targets at infinite focus for critical visible, IR, SWIR, MWIR and LWIR system testing. STC Series Collimators integrate with SBIR’s Infinity Blackbodies and 300 Series target wheels to create the 14000 Series Target Projectors. These target projectors are available in many standard sizes to satisfy the test requirements of most sensor systems. Additionally, their modular design allows for easy customization of components.
-
Product
Target Wheels
-
Santa Barbara Infrared manufactures a wide variety of standard and custom target wheels, to conveniently and accurately position multiple targets in front of a blackbody source. The SBIR 300 Series Target Wheels are specifically designed to be used with SBIR’s standard differential blackbody sources and integrating sphere light sources. These motorized target wheels are available in several standard models to accommodate different sizes and numbers of targets.
-
Product
IR/Visible Target Projectors
-
Santa Barbara Infrared’s reflective infrared and visible target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) and visible imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies, Infinity VSX Integrating Spheres and 300 Series Target Wheels.
-
Product
CN-37 Blackbody
-
Compact thermal camera reference source. Compatible with all thermography cameras on the market and IEC 80601-2-59 compliant. Available now, ready to ship.
















