Voltage Indicators
1) Digital Voltage Indicator. 2) Digital Visual Interface, is a standard for a uniform connector that can handle both digital and video signals.
See Also: Indicators, Angle Position Indicators, Fault Indicators, Loop Indicators
-
product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779373-01
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
product
Shunt Voltage References
Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.
-
product
Voltage Dip & Swell Simulators
VDS Series
A simulator to reproduce voltage variation phenomena in commercial power supplies (AC100V/200V).This type of immunity test against voltage variation phenomena is defined in IEC 61000-4-11 and is widely used in many industries.
-
product
Solid State Voltage Injector
J2110A
While it is possible to obtain high quality injection transformers with bandwidths as wide as 1Hz to 5MHz or more, in some cases this is still insufficient for some tests. For example a typical heater control loop might have a bandwidth of less than 1Hz while some linear regulators and opamp circuits can have bandwidths of up to 100MHz or in some cases even higher. For these applications, a solid state injector can provide the necessary bandwidth. A solid state injector can perform at DC, while the upper frequency limit is dictated by the components selected and the printed circuit board material and layout. It is possible to obtain a solid state injector with a working range of DC – 200MHz, though above 50MHz the interconnection between the injector and the circuit being tested can become quite critical. It is essential that ripple from the injector power supply does not dramatically degrade the dynamic range or the signal to noise ratio of the measurement. The resulting plots are often much cleaner when using a solid state injector than with a transformer injector.
-
product
Surge Voltage Generator
SSG 500
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 500. The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protection and system earth.* 6 output voltages up to max. 16 kV available* Electromagnetically actuated surge switch* Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)* Automatic discharge unit
-
product
High Voltage Phasing Sticks
9007KB Series
Shanghai Beha Electronics Co., Ltd.
*Important applications include checking voltage fuses, testing for correct phase connections, and for absence of high voltage on deenergized lines or apparatus.*measuring ranges from 6.6kV up to 44kV systems*Fiberglass is of hot stick quality and tested to IEC specs (100kV/300mm for 1 min). All front end (resistors) are encapsulated.
-
product
Power ICs - MicroBUCK® - Voltage Regulator
*Highly integrated microBUCK POL solutions deliver high efficiency while reducing costs*Each family offers a large portfolio of high density parts with common pinouts, allowing designers to scale for the best combination of cost and performance*Our PowerCAD simulation tool allows users to select the appropriate microBUCK regulator and generate a full circuit schematic**For performance optimization and comparison purposes, the schematic can then be edited as required.**Once the basic circuit is created, the user can perform DC, transient, and start-up simulations with visibility of all the circuit node waveforms.**Following these steps, the PowerCAD 2.0 simulation tool generates a bill of materials (BOM) available for online ordering.
-
product
Non-Contact Voltage Tester
NCVT-3
Provides non-contact detection of AC voltage.Detects 12 – 1000V AC with simultaneous visual and audible voltage indicators.Bright flashlight illuminates work area and may be used independent of voltage detection function.Visual LED bar graph indicates the presence of voltage – the higher the voltage sensed, or the closer to the voltage source, the more LEDs light up.Bar graph visual voltage indicator utilizes up to five vibrant LEDs for easy interpretation/viewing.Audible voltage indicator beeps at a greater frequency the higher the voltage that is sensed, or the closer to the voltage source.“Auto Power-Off” conserves and extends battery life.Screw-thread battery cap with O-ring ensures protection against dust and water ingress.Lightweight, compact tool with pocket clip provides convenient storage and quick access.IP67: Dustproof and waterproof.6.6 feet / 2 meter drop protection.CAT IV safety rating for 1000V.Conforms to CE requirements.
-
product
High Voltage Test Equipment
A hipot test is conducted by ensuring no current flows from one point to another on a circuit. A hipot test will take two conductors that should be isolated from one another and passes a high voltage between the two points. The current which flows between these points is then measured. If too much current flows, this would indicate that the points are not well isolated and the test will fail.
-
product
Low Voltage Burn-in and Test System
Max 450
For burning-in and testing DUTs such as microprocessors, DSPs and logic devices, which require low voltage. Output monitoring gives functional test results for every device during burn-in
-
product
Electrical Tester For Voltage
PDT35
Automatically Selects VAC, VDC, or Continuity TestComplies with EN 61010-1 For Use in CATIII 600 V Environments1999 Count LCD DisplayAuto Power On/OffHigh Input Impedance -- 400 kVoltage AC: Max Range 600 V, Accuracy +/- 1.5%Voltage DC: Max Range 600 V, Accuracy +/- 3.0%Continuity TestAccessories Included: Test Leads, 2 'AA' BatteriesDimensions: 8.46' H x 2.83' W x 1.44' DWeight: 8.29 oz.Sold as : Unit
-
product
High Voltage Op Amplifiers ≥12V
High supply voltage op amps are used in systems that demand the widest dynamic range with the best signal-to-noise ratio. Engineers turn to Analog Devices for high voltage amplifiers that deliver industry-leading performance. Increasingly, new high voltage amplifiers also offer features to improve system performance, cost, and robustness while easing the complexity of system design. New features include integrated input overvoltage protection (OVP), on-chip electromagnetic interference (EMI) filtering, higher electrostatic discharge (ESD) immunity, and greater resistance to latch-up in both powered and unpowered operations.
-
product
Hand held, Battery-Powered Voltage Source
DVC-350A
Hand held, lightweight 11 ounce (342 grams)Laboratory accuracy of 0.015% of FSR at +25 C, traceable to the National Bureau of Standards4 1/2 Digit LCD display100 V incrementsTwo output voltage rangeDecimal: 1.2V dc, 12V dcHexadecimal: 1V dc, 10V dc
-
product
120-600V Solenoid Voltage And Continuity Tester
1865
Peaceful Thriving Enterprise Co Ltd
This solenoid voltage tester has multiple functions. It tests for voltage, continuity and polarity.
-
product
Series Voltage References
Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.
-
product
High Voltage Test Sets
Nmc's high voltage test sets are manufactured as per the customers requirement ranging from 5kv-100kv ac or dc.
-
product
Voltage Detectors
Non-contact voltage detectors can quickly detect live AC voltage. These handy devices are great for electricians to safety and quickly check the status of electrical wires.
-
product
Voltage Controlled Linearized Attenuators To 16 GHz
Pulsar's voltage controlled, PIN diode linearized attenuators are available from 0.25-16 GHz with attenuation ranges of 32 and 64 dB. Each model includes an integrated linearizer, and a driver that controls the attenuation level. This design results in transient free switching between attenuation levels as opposed to the spurious outputs that result when an attenuation value is switched either on or off by a direct digitally controlled attenuator. Transfer function is 8 dB / Volt.
-
product
Voltage Tester With Wire Stripper
7122A
Peaceful Thriving Enterprise Co Ltd
The product can measure AC voltage 10V to 1000V and DC voltage 7V to 1000V with polarity indication. All testing results will be displayed by LCD. This product can also measure continuity and RCD. Eventually, for the convenience of wire stripping and cutting, this product has combined the function of wire stripper.
-
product
Standard Voltage Transformer
HJ / 635
Wuhan Huatian Electric Power Automation Co., Ltd.
It is mainly designed for the voltage transformer calibration standard of basic power supply and production department.
-
product
High Voltage Divider
The High voltage divider type HVT ... RC possess from DC up to their cut-off frequencies in the MHz range uniformly excellent transmission characteristics. The voltage divider consists of a resistive branch, which is constructed of high-grade resistance, and a capacitive branch with series damping.
-
product
Dual High Voltage Power Supply Tester
MS 1110
DHVPS Tester is used to test and service the dual high voltage power supply units. High Voltages of range from 4KV to 11KV can be tested.
-
product
AC Voltage Proving Units
HLV-1
Standard Electric Works Co., Ltd
● Designed to proof. AC voltage detectors AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.
-
product
Non-Contact Type Phase Sequence Indicator
890 PR
Standard Electric Works Co., Ltd
● The 890 PR is a Non-Contact phase detector with flashing LEDs and a beeping buzzer to show the detection of AC 3-phase sequence.● Two functions in one unit : open phase and phase sequence detection.● Convenient brightness switch to make the indication visible in dim areas or sunlight.● Back cover magnets which attach the instrument to the AC distribution panel offer easy measurement. ● 3-Phase AC 75 to 1000V is fitted for detection.● Conductor size: 1~35mm● Detect frequency range is from 45 to 65Hz.
-
product
Voltage Tester
HH2611
Handy, quick response and easy to use tool. Safe to use Non-Contact testing 90-220V AC voltage. Delect AC voltage without connecting into the wire circuit. Very bright LED and buzz sound alarm if voltage is present. Used to detect where the wire is broken. Used to detect whether an outlet is present of voltage. Used to detect a broken Christmas bulb out of a series of connected Christmas bulbs
-
product
High Voltage DC Cable Test Systems
We can offer from ±18kVdc to ±30kVdc units which all have automatic earthing for discharging capacitive loads. They are designed to perform tests on installed cables and jointing systems.
-
product
Impulse Voltage Generator
Shanghai Sanki Electronic Industries Co., Ltd.
Impulse voltage generator Impulse voltage generator is mainly used for test products such as power equipment to perform lightning impulse voltage full wave, lightning impulse voltage chopping, operating impulse voltage wave and steep wave impulse voltage test, to inspect insulation performance. The technical indicators comply with national standards and IEC standards.
-
product
Inspection Instrument for Indicators
i-Checker
The i-Checker is specially designed to calibrate measuring accuracy of dial indicators, dial test indicators, and other electronic comparison gage heads with a stroke of up to 100mm (4").±(0.2+L/100)µm indication accuracy. Directly inspects an indicator with a stroke of up to 100mm (4"). The dial test indicator, bore gage and lever-type inductive head can be inspected with optional accessories. Adjustment of the measurement position is very easily accomplished because of semi-automatic measurement and full automatic measurement functions. Creates and prints out the simple inspection certificate. Saves inspection result as CSV file for reusable inspection result by any kind of software.