Showing results: 91 - 105 of 173 items found.
-
Dr-Jordan-Design
All these measurement microphones have a XLR connector and require a phantom power. They can be connected to specially equipped soundcards or pre-amplifiers, only.
-
HT378B02 -
PCB Piezotronics, Inc.
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
378C01 -
PCB Piezotronics, Inc.
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
RjP-600 Series -
Laser Probe Inc.
The RjP-600 Series energy probes integrate the detector and preamplifier in the same enclosure, thereby maximizing signal integrity between the detector and preamplifier. This permits longer cable runs between the probe and instrument, as is often necessary in production environments. Probe specific information, like calibration date and wavelength response curves, is stored in the probe for access by the instrument. Other features include interchangeable filter holders and ¼-20 mounting hole.
-
Supracon AG
Our current sensors were designed for a simple, customer-specific construction of niobium wire wound magnetometers, gradiometers or preamplifiers for small current or voltage signals.
-
ZET 410 -
ZETLAB Company
The ZET 410 preamplifier is used as a signal amplifier in processing systems and various instruments and actuator control systems. It is used in industry, laboratory and mobile studies.
-
Hybrid -
Amptek Inc.
Get the best performance with solid state detectors, proportional counters, photodiodes, PM tubes, CEMs, or MCPs by using Amptek Charge Sensitive Preamplifiers
-
RkP-400 Series -
Laser Probe Inc.
The RkP-400 Series probes consist of a compact head containing the detector and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1” (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
RjP-400 Series -
Laser Probe Inc.
The RkP-400 Series probes consist of a compact detector assembly, or head, and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1" (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
RESON TC 4032 -
Teledyne Marine RESON B.V.
The TC4032 general purpose hydrophone offers a high sensitivity, low noise and a flat frequency response over a wide frequency range. The high sensitivity and acoustic characteristics makes TC4032 capable of producing absolute sound measurements and detecting even very weak signals at levels below “Sea State 0”. The TC4032 incorporates an electrostatically shielded highly sensitive piezoelectric element connected to an integral low-noise 10dB preamplifier. The TC4032 preamplifier is capable of driving long cables of more than 1.000 meters, and the preamplifier features an insert calibration facility.
-
Block Engineering, LLC
The MCT (Mercury-Cadmium-Telluride) IR (infrared) Detector Module is a thermoelectrically cooled detector element and preamplifier package optimized for acquiring spectral data with the LaserTune Quantum Cascade Laser (QCL) source.
-
LA-60 -
ECG KOKUSAI Co., Ltd.
In adoption of a detector with a built-in preamplifier, a LA-60 type leakage-of-water discovery machine has little surrounding influence of noise vibration, and can perform listening of leakage-of-water sound more faithfully.
-
LNAM-LPA -
Magnicon GmbH
We offer an evaluation board and case for the LNAM-B and LNAM-FBX modules. This Laboratory PreAmplifier (LPA) solution is powered by a switch-mode power supply and gives access to the LNAM in- and outputs via BNC sockets.
-
S97029B -
Keysight Technologies
The instrument’s standard receivers are used for noise figure measurements with the S97029B. An external preamplifier and filter(s) is required for devices with < 30 dB of excess noise (gain plus noise figure in dB)
-
TC 4037 -
Teledyne Marine RESON B.V.
Incorporating a 10dB low-noise preamplifier able to drive a 25-metre cable and a wide usable frequency range, the TC 4037 is a spherical probe hydrophone that’s ideal for measuring sounds in the 100 to 500kHz range.