Preamplifiers
Detect and strengthen a signal prior to greater amplification.
See Also: Amplifiers, RF Amplifiers, Current Amplifiers, Audio Amplifiers, Voltage Amplifiers, Transconductance Amplifiers, Op Amps, Klystron, Instrumentation Amplifiers, Distribution Amplifiers
-
Product
16 Channel USB Sensor Interface
RogaDAQ16
-
With the introduction of the RogaDAQ16 USB 2.0 data acquisition system, a new age of measurement technology begins.*USB 2.0 / 480MBIT (USB1.1/12MBIT COMPATIBLE)*16 analog input channels (16bit/500kHz max.)*ICP ® ( IEPE ) sensor supply (24V/4mA)*0.125V to 10V input range*Individual preamplifiers*4 analog output channels (16bit/100kHz)*Powerful DSP (255MIPS) for filtering, control etc.*24 digital I/Os*Optional 24bit counter, timer, PWM, incremental encoder*Free drivers for major application software*including DASYLab; LabView & DiaDem drivers & RogaRec Software
-
Product
MCT IR Detector Module
-
The MCT (Mercury-Cadmium-Telluride) IR (infrared) Detector Module is a thermoelectrically cooled detector element and preamplifier package optimized for acquiring spectral data with the LaserTune Quantum Cascade Laser (QCL) source.
-
Product
Microphone Preamplifier
426B31
-
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
Product
Active Input Module for Teledyne RESON TC4014 and TC4032, Hydrophones with Built-In Preamplifiers
EC6076
-
The EC6076 Active Input module is for the Teledyne RESON TC4014 and TC4032 hydrophones with built-in pre-amplifiers.EC6076 provides an easy interface to the hydrophones, it al-lows use of the differential output from the hydrophones ei-ther via direct feedthrough of the signal on an XLR output con-nector or via the built-in differential amplifier that converts the differential hydrophone signal into a single-ended +6dB signal on a BNC/coax out. EC6076 has a built-in rechargeable battery that provides power for the EC6076 differential amplifier and the TC4000 hydrophone.
-
Product
Precision Current Preamplifier
SIM918
-
Stanford Research Systems, Inc.
The SIM918 Current Preamplifier is ideal in applications in which the input offset voltage must be kept to a minimum. The DC voltage difference between the two inputs (current input and voltage bias) is accurately measured every 2 seconds, and is nulled.
-
Product
Low Noise Amplifiers for Radio Amateurs
-
Our Low Noise Preamplifiers are remarkable for extremely low noise, excellent SWR, high efficiency and a high IP3. The Low Noise amplifiers are especially selective and absolute stable therefore oscillation is avoided. Even if you have a bad SWR. This is the reason why radio amateurs and club-stations all around the world trust in Kuhne electronic equipment. The products are perfect for use in contests, EME, MeteorScatter, Aurora and Tropo DX. Small mechanical measurements and technical innovations from the professional sector, e. g. milled aluminium cases, enable high temperature stability and tower mounting. Numerous contest victories, records and first contacts with a country were and are achieved with Kuhne products. Don't compromise and get technology from Kuhne electronic!
-
Product
Amplifiers
-
Teledyne Lincoln Microwave design and manufacture RF amplifiers utilising the latest semiconductor technology. Our portfolio includes low noise amplifiers (LNA’s), power amplifiers and pre-amplifiers. These can incorporate linearization, filtering, phase and amplitude control functionality.
-
Product
Precision Condenser Microphone
378A12
-
1/4-inch pressure prepolarized 377A12 microphone, with 1/4-inch preamplifier 426B03 and TEDS v0.9
-
Product
Modern Prepolarized Precision Condenser Microphones & Preamplifiers
-
Modern prepolarized microphones are designed with newer technology than traditional externally polarized microphones. Prepolarized microphones have many advantages over the externally polarized models. They use ICP® power circuitry invented for sensors by PCB®. By applying a polymer coating to the top of the backplate and embedding a charge on it, expensive 200V power supplies can be eliminated and 2-20 mA constant current supplies or signal conditioners can be used as the power source.
-
Product
Energy Probes
RjP-600 Series
-
The RjP-600 Series energy probes integrate the detector and preamplifier in the same enclosure, thereby maximizing signal integrity between the detector and preamplifier. This permits longer cable runs between the probe and instrument, as is often necessary in production environments. Probe specific information, like calibration date and wavelength response curves, is stored in the probe for access by the instrument. Other features include interchangeable filter holders and ¼-20 mounting hole.
-
Product
CZT Gamma-Ray Detector Spectrometer
GR Family
-
The Kromek GR family is a range of CZT-based high-performance gamma-ray spectrometers. They are completely self-contained, with built-in preamplifier, shaping amplifier, baseline restorer, pulse height digitizer, and HV supply. The digitized pulse heights of detected gamma-ray signals are sent to a PC via the USB. The unit is powered entirely from the USB bus, so no external power supply is needed.
-
Product
Microphone System
378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Headphone Test Fixture
AEC206
-
The Larson Davis Model AEC206 Binaural Test Fixture is the tool for testing supra-aural, circumaural, supra-concha, intraconcha, and insert-type headphones. Preassembled with IEC 60318-4 (711) occluded-ear simulators and TEDS compatible preamplifiers that provide electronic calibration information, the Model AEC206 is user-friendly and easy to learn. Additionally, calibration is a simple process—a custom adapter is included for the Model CAL250 acoustic calibrator or similar device.
-
Product
Preamplifiers
-
A.H. Systems'' Preamplifier line is an excellent choice with a rugged design, no hassles with soldering your own power leads and they improve overall system sensitivity by at least 20 dB. All of A.H. Systems'' Preamplifiers come with a 12-volt (or 15-volt) DC regulated power source. A low voltage indicator confidently allows you to power the amplifier with your own external 12-volt DC battery. This makes it a convenient choice for field measurements. See table below for amplifier specifications.
-
Product
Preamplifiers
-
Is an electronic amplifier that converts a weak electrical signal into an output signal strong enough to be noise-tolerant and strong enough for further processing, or for sending to a power amplifier and a loudspeaker.
-
Product
Preamplifier, 100 MHz to 18 GHz
87405C
Amplifier
Exceptional gain (25 dB) and flatness (1.5 dB) combined with a probe-power bias connection which eliminates the need for an additional DC power supply, makes these preamplifiers the ideal choice for spectrum analyzer or stand alone applications.
-
Product
ELT STALKER Vector-finder
VF-121
-
The Vector-Finder Types VF-121 and VF 121A are unique in the Vector-finder series of direction finding antennas. They incorporate a proven design, electro statically shielded loop sensing element with modern solid state low noise analog and digital technology to allow detection and location of aircraft band signals. Both the VF-121 and the VF 121A incorporate a unique digital modulator which allows the user to more easily home-in on unmodulated carriers. Such cases occur at airports when transmitter may be accidentally keyed on during aircraft overnight layovers. The VF-121 is specifically designed to be used on airport premises where signal strengths are high. To compensate for very strong signals, an integral attenuator is also incorporated to allow the user to operate the unit close-in to aircraft. The VF-121A differs in that a high gain, low-noise preamplifier is utilized with the sensing element in order to hunt signals that may be weak or at a distance. The unit is ideally suited for the location of ELT transmitters in the field. Both units are tunable over the 118 MHz to 130 MHz aircraft frequencies and interface directly to the user’s aircraft band receiver or transceiver via the antenna jack. With the antenna system connected to the receiver, the user will hear the desired signal. If the signal is unmodulated, the digital modulator will generate a tone on the carrier. When the handheld unit is rotated about, an audible null on the received signal or the generated tone will be heard. This null aligns with the axis of the equipment case and represents the direction of the received signal. This direction may be read from the black dial compass mounted on the top of the enclosure. As the response is bi-directional, triangulation may be used to determine the true bearing when the true direction is not known.
-
Product
350 MHz Preamplifier
SIM914
-
Stanford Research Systems, Inc.
The SIM914 350 MHz Preamplifier contains two wide-bandwidth, DC-coupled amplifiers, each with a gain of 5 (14 dB). Its fast rise time, low noise and excellent DC accuracy make it an ideal instrument for amplifying signals like those from photomultiplier tubes and photodiodes.
-
Product
High-Sensitivity Tri-Axial Accelerometer with Built-In Preamplifier
NP-7310
-
NP-7310 is the accelerometer with built-in preamplifier, and capable of tri–axial directions simultaneous measurement. It is suitable for the low frequency vibration measurement such as ground vibration or floor vibration while operating the machine. NP-7310 can be used with the sensor amplifier unit such as AU-2100, AU-2300 or PS-1300. Also, it is possible to input directly to the analyzer or recorder which the constant current amplifier is built-in such as the FFT Analyzer of DS-2000 series, DS-3000 series, CF-7200A, CF-9000 series or CF-3650/3850 series.
-
Product
PXIe-5668, Up to 26.5 GHz PXI Vector Signal Analyzer
783156-03
Signal Module
Up to 26.5 GHz PXI Vector Signal Analyzer - The PXIe‑5668 offers wide bandwidth with high-performance measurement performance and speed. It meets the challenging requirements of applications such as wireless communications, radio frequency integrated circuit characterization, RADAR test, and spectrum monitoring and signal intelligence. With its implementation as a PXI instrument, the PXIe‑5668 also features the fast measurement speed required for high-volume manufacturing test, and multi-instrument synchronization capabilities for phase-coherent MIMO test. You can use the optionally included PXIe-5698 preamplifier to improve dynamic range and sensitivity near the instrument noise floor.
-
Product
Acoustic Emission Preamplifier
-
The Acoustic Emission Preamplifier is a instrument designed specifically for use with acoustic emission sensors, which is used to boost the signals and filter out any noise or interference. With its advanced technical features and robust design, the QingCheng Acoustic Emission Preamplifier is the perfect choice for professionals seeking a high-performance acoustic testing solution.
-
Product
FieldFox Handheld Microwave Spectrum Analyzer, 4 GHz
N9933B
Spectrum Analyzer
A lightweight, durable, microwave spectrum analyzer, interference analyzer, distance-tracking generator, preamplifier, power meter, and more.
-
Product
Pulse energy and power measuring instrument
LEM 2410
-
A touch panel and function keys make this device comfortable and easy to handle. The preamplifiers integrated into the device and the choice of sensor sensitivity allow a wide range of sensor heads to be used. The large graphic display offers space for a variety of display and analysis choices. The digital display can be used for determining the energy, frequency and average power.
-
Product
Measurement Microphones
-
The microphone bodies contain the preamplifier. They combine high dynamic range and wide frequency range with low noise. These measurement microphones connect via the ASD Cable to the XL2 Audio and Acoustic Analyzer, e.g. for measurements at remote locations or to reduce acoustic reflections.
-
Product
Filtered Preamplifers
FPA
-
These low noise figure, high gain preamplifiers provide low system noise figure andallow longer antenna to receiver cable lengths. Preamplifiers can be specified withseveral filter configurations.
-
Product
Current Preamplifier
1641
-
The Model 1641 Current Preamplifier is a simple low cost wideband gain block for use with photomultipliers
-
Product
Miniature AE Sensor With Isolated Integral 30 DB
-
The Guzik miniature AE sensor with isolated integral 30 dB preamplifier has a wide-band and excellent frequency response over the range of up-to 1 MHz. Its small size makes the sensor ideal for hard disk drive test or similar applications requiring very small size, low weight, wideband AE sensor response and high sensitivity. A small diameter, external flexible cable connects the sensor with a 3-pin JST connector on the other end.
-
Product
Microphones/Preamplifiers
-
To apply gain to (amplify) the signal without changing how the signal sounds.
-
Product
Low Cost Microwave Wideband APD Preamp Receivers
MR11 (40KHz~18GHz)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
MR11 series microwave wideband optical receiver, adopts high Sensitivity APD diode and Low Noise Preamplifier IC, within bandwidth of 40KHz~18GHz, they are featured with excellent linearity, high responsibility and superior flatness of the RF response in both, power and phase. They provide an outstanding linearity fiber optical communication for analogue wideband microwave application. Due to avoidance of using expensive coaxial cable or wave-guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless, timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s high speed communication system.
-
Product
Probes For Non-Contact Ultrasonic Testing
SONOSCAN CFC / CF
-
Due to the strong damping properties of air, low frequencies in the kHz range are used in air-coupled ultrasonic testing. It is therefore all the more important that the ultrasonic transducers offer a particularly high sensitivity in order to ensure high penetration and improved resolution. We achieve this, among other things, by installing preamplifiers in the receiver probe as well as by using our own Piezocomposite Technology, which enables a flexible use of the matching materials in our CFC and CF probes.