product
311 HP Eddy Current Chassis Dynamometer
CM-51S-EC
Weight Capacity: 25,000 lb (11,340 kg) per axleRoll Brakes: pneumatically-actuated discShipping Weight: 5,100 lb (2,312 kg)Capacity: 311 hp at 45 mph (232 kW at 72 kph)Rolls: 20 by 36 in. (508 by 915 mm) long, 4 fixedPit Required Depth: 25 in. (635 mm)
-
product
Eddy Current Probes and Drivers
Proximity sensors work on the eddy current principle. A proximity system consists of an eddy current probe, extension cable and driver. A high-frequency RF signal is generated by the driver, sent through the extension and probe cables and radiated from the probe tip. The tip consists of a precision wound copper coil inside a chemical and temperature resistant PEEK case.
-
product
Micsig Ocilloscope AC Current Probe
ACP1000
Shenzhen Micsig Instruments Co., Ltd.
*Test Current Range: 0.1A-1000A*Operating Frequency: 10Hz-100kHz*Maximum Primary Current: 2000A (2s)*Output Signal: mV/A*Highest Precision: 1%
-
product
Analog AC Leakage Current Clamp Tester
MCL-350
MULTI MEASURING INSTRUMENTS Co., Ltd.
*High accuracy analog display with strong taut band meter.*3 years long battery life.*Meter lock function and data output for recorder.*Filter rejection for high frequency noise
-
product
Current Logger0 to 25mA DC
TV-4804
The TV-4804 measures current from 0 to 25mA DC and can be connected to a variety of industry standard sensors enabling the logging of a wide range of process parameters.
-
product
Primary Current Injection Testers
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
product
ANSI Metering Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
Custom Radio Direction Finding Products
This assembly contains three sets of antennas, three RF summers, an antenna switch, a GPS and (optionally) a flux gate compass. The pod mounts to the roof with nylon straps, although it is recommended that it be bolted down for more permanent applications. Although this antenna is not stocked, we can provide them on relatively short notice. No minimums apply.
-
product
Current Probe With Hall Effect Technology
CP 35
The CP 35 current probe has been designed for use with oscilloscopes respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
product
Clamp Meter AC Current 1999 Counts
VA310 VA310C
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Diode Test Back Light Continuity Buzzer.
-
product
RF Directional Coupler Elements
87000 Series
The Coaxial Dynamics 87000 series X-Tractors are directional RF Signal Sampler Elements designed to permit easy coupling into a coaxial line for counting of frequency, spectrum analysis or scope display.
-
product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-3000
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Ultra big CT window*AC 1A~3000A*Current measurements of main cable
-
product
Current Analyzer Control And Automation App
BV0013B
Intuitively control your current analyzer, build automated tests, and log data easily with BenchVue current analyzer software app for deeper current analysis.
-
product
VECTOR-GUN HANDHELD DIRECTION FINDING ANTENNA SYSTEM
HFDF
National RF's Type HFDF active directional antenna system consists of a high gain RF amplifier coupled to a tunable Faraday shielded loop antenna. Several loop antenna assemblies are available to provide coverage of frequencies in the HF and low VHF spectrum. Due to the nature of a Faraday shielded loop, the antenna exhibits a sharp null through the diametric center of the loop. This null is used to determine the direction of incoming radio signals or to locate electrical noise being radiated from some source. The internal high gain amplifier is used to compensate for the inherent inefficiency of the actual loop at the operating frequency. Overall, the system dynamic response is about +6 dB as compared to the dynamic response of a dipole. To aid in the direction finding process on strong signals, an internal 30 DB attenuator is provided. As the loop antenna presents a bi-directional response, tri-angulation may be required to eliminate the ambiguous signal direction. The line of site of the incoming signal is determined by listening for a signal null on the receiver or by watching the receiver’s S-meter.
-
product
Screen Channel Sound Solution For Direct View Displays
Ultra Reflex
Cinema technology is always in motion. A new generation of large-scale direct view displays offer high dynamic range, extraordinary contrast ratios, tonal detail, and flexible color space. But because direct view displays are solid, speakers cannot be placed behind them to localize sound to the action onscreen. The patent-pending Meyer Sound Ultra Reflex system is the first screen channel loudspeaker solution to provide precise localization for direct view displays.
-
product
AC Current Probes
CWT
Power Electronic Measurments Ltd
The CWT Rogowski current probe is suitable for measuring AC currents ranging from 300 milliamps to hundreds of kA from below 0.1Hz to >30MHz.
-
product
MCB Tripping Current Characteristic Test Bench
The SCR Elektroniks 12 station MCB Tripping Characteristics Test Bench is optimally designed to verify the Tripping Characteristic of MCBs as per clause 9.10.1 of IEC 60898 (Also mentioned in Indian Standards IS 8828). The bench essentially comprises of Servo Controlled mechanism to set and maintain desired current (against incoming mains fluctuation) and a Micro controller based master controller unit plus timer, which governs the entire sequence of operation making it a stand-alone system once the user connects the MCB and configures the test parameters.
-
product
Zero Phase Current Transformer
MZL-30
MULTI MEASURING INSTRUMENTS Co., Ltd.
Split-core type for measuring zero phase current
-
product
Multifunction Voltage and Current Calibrator
MC140i
Multifunction calibrator MC140i is ideal for calibration of voltmeters, ammeters, DMMs and panel meters. AC/DC voltage 1uV to 1000V. Current 50uA? to 1000A using test coil. Deviation control along readout. 0.0035% basic dc accuracy. 0.03% basic ac accuracy. Supplied with RS232 interfaces. UKAS/NIST Traceable
-
product
Mini AC Leakage Current Clamp Tester
M-100+
MULTI MEASURING INSTRUMENTS Co., Ltd.
・18mmφCT window and ultra compact size.・Least affection from the external magnetic field.・The special alloy is used for core material that resists the rust over long period of use and ensures stable,high accurate measurements with very slight influence from aging.
-
product
Clamp type AC Current Sensor/with DC Voltage Output
ACT-5H
MULTI MEASURING INSTRUMENTS Co., Ltd.
*For current measurements of the control board*AC 0.1A~5A*DC 5V full scale output
-
product
1310nm Direct Modulated Optical Transmitter
ONT-8600AR
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai 1310nm direct modulation optical transmitter, adopts high linearity DFB laser of famous brand in the world, and builds-in perfect pre-distortion adjustment circuit and laser APC, ATC closed loop control circuit. All the operating parameters are controlled by microprocessor, and the LCD screen on the front panel can display relative operating status and the fault information. ONT-8600AR has all the technical characteristic and function of ONT-8600AS. For its rainproof structure, it can be installed outside and its power supply is 220VAC or 60VAC optional.
-
product
Profiling Current Meter and Wave
SeaGuardII DCP Wave
The SeaGuardII DCP Wave is a 600kHz Doppler Current Profiler able to measure directional wave parameters and currents from a bottom mounted installation.The Acoustic Wave software 5759 used by the DCPS implements unique features to improve the wave measurement accuracy by optimizing the signal to noise ratio.Maximum deployment depth is 40m in normal scatter conditions. The Profiling Current Meter and Waveis available as a self-recording instrument. It can be easily integrated into a real-time system offering reliable two-way communication.
-
product
Rugged Igniter Tester With Current Monitor And Single Connection For Measurement And Charging
4314 KVM
The Valhalla Scientific Model 4314 KVM Digital Igniter Tester is designed to provide extremely safe and reliable resistance testing of explosive or volatile devices. Proven uses include fuses, squibs, igniters, explosive bolts, automobile airbag initiators and many others.
-
product
Direct BNC
0001045
Interface board plugs directly into National Instruments 68 pin multifunction and simultaneous sampling DAQ cards (PCI and PXI). First four analog inputs, two analog outputs, and trigger channels are available on BNC connectors (SMA/SMB optional).
-
product
6-8 DB Directional Couplers From 0.5 To 40 GHz
Pulsar Microwave manufactures the CS06 and CS08 series single directional couplers in nominal values of 6 and 8 dB, respectively. These directional couplers are used in 50-ohm systems for narrow and wideband applications within 500 MHz to 40 GHz. Standard outlines are fitted with SMA or N type female connectors, but Pulsar Microwave can customize upon request.
-
product
Current Transformer
ST-9RCT
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 800~2000
-
product
AC Current Clamp Adapter
LAD-1100
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Selectable measuring range 30mA~30A with CT ratio 10:1 and 30A~3000A with CT ratio 100:1.●φ110mm CT window, possible to measure from leakage to big current up to 3000A.
-
product
Mini AC Leakage Current Clamp Tester
M-104+
MULTI MEASURING INSTRUMENTS Co., Ltd.
・33mmφCT window and ultra compact size.・Data-hold function. Especially useful when working in dark or hard to get areas.・Low cost type, Core shielding is not equipped.
-
product
Integrated Current Sensors
Current sensors have to be smaller, smarter, cheaper. LEM’s R&D is actively developing a range of ICS to reduce the footprint of the current sensing function and simplify the integration of current measurement in a wide range of applications in automotive, industrial, or residential.