Vapor
-
product
Vapor Relays & Contactors
From rail passenger cars and locomotive control and starting circuits to earth moving equipment, Vapor relays and contactors have established a reputation for quality and reliability where dependable control of DC circuits is required. Performance-proven in thousands of applications worldwide, Vapor relays and contactors meet or exceed stringent qualification requirements of major locomotive and rail passenger car builders and heavy machinery manufacturers. Units are in daily service on U.S. Class 1 railroads, the New York City Transit Authority, the Chicago Transit Authority, the Toronto Transit Commission and other railroads and transit agencies around the globe.
-
product
Ozone Gas Generators
SEMOZON® Ozone gas generators and subsystems are the industry standard for compact, high concentration, ultra-clean ozone gas generation. Applications include Atomic Layer Deposition (ALD), Atomic Layer Etch (ALE), Chemical Vapor Deposition (CVD) and Wet Cleaning.
-
product
Vapor Source Mass Flow Controller With Viscous Laminar Flow
The 1152C Vapor Source Mass Flow Controller is a pressure-based measurement and control system designed to meter and control vapor from low vapor pressure liquid and solid sources directly, without the need of a carrier gas. The 1152C consists of a fixed flow element and two capacitance manometers for flow measurement, with a proportioning solenoid control valve for flow control.
-
product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
product
Water Vapor Permeability Analyzer
Guangzhou Biaoji Packaging Equipment Co., Ltd.
GBPI Water Vapor Permeability Analyzer used to test the water vapor transmission rate (WVTR) of packaging materials, such as plastic film, composite film, coextrusion film, aluminum-plated film, aluminum foil.
-
product
Control Module for Combustible Apps
4802A
The 4802A is a single channel Combustible Gas Control Module that has been designed for use with General Monitors catalytic bead sensors. It is designed to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs.
-
product
Portable Fuel Dilution Meter
FDM 6000
The FDM 6000 is a portable, battery operated fuel dilution meter that determines the concentration of fuel dilution present in an oil sample within a matter of minutes. The FDM 6000 uses a unique patent pending fang design to pierce the cap of a disposable sample vial and draws in the headspace from the vial. The headspace flows over a SAW (Surface Acoustic Wave) sensor which reacts specifically to the presence of fuel vapor with a detection range of 0 – 15%. It can detect diesel, gasoline or jet fuel in engine oil. It conforms to ASTM D8004 - "Standard Test Method for Fuel Dilution of In-Service Lubricants Using Surface Acoustic Wave Sensing"
-
product
Principle Of Optical Emission Spectrometry
Optical emission spectrometry involves applying electrical energy in the form of spark generated between an electrode and a metal sample, whereby the vaporized atoms are brought to a high energy state within a so-called "discharge plasma".
-
product
Quadrupole Mass Spectrometer for Residual Gas Analysis
RGA Series
Systems for the examination of components present in a vessel or evolved from a process. HALO RGA – for residual gas analysis. 3F Series RGA – triple filter mass spectrometers for analytical applications. 3F-PIC – pulse ion counting detection for fast event studies. Measures the concentration of gases and vapours in real time.
-
product
Portable Sulphuric Acid Dewpoint Temperature Monitor
The fuels used in boilers, such as coal, heavy oil and natural gas, contains S. during the combustion process, S and O₂ form SO₂, and a small amount of SO₂ is converted into SO₃ under catalysis of Fe₂O₃, V₂O₅ and other catalysts. Under normal circumstances, the volume of SO₃ in the boiler flue gas is 1×10-6~50×10-6, and the water vapor is about 10%. When the temperature of the flue gas is below 200°C, SO₃ and the water vapor are completely combined into H₂SO₄ vapor. A small amount of H₂SO4 vapor will significantly increases the acid dew point. When the surface temperature of the boiler heat exchange equipment is lower than the flue gas acid dew point, the H₂SO₄ vapor will condense on the surface to become sulfuric acid solution with a concentration of about 80%, which will adhere to the surface of the heat exchanger and cause acid corrosion. Typical equipment that is prone to corrosion includes air preheaters, induced draft fans and flue walls.
-
product
Cockpit Software for Vision Analyzers
COCKPIT™ offers the utmost in flexibility. Lab managers use the PC software for Vision analyzers to consolidate measurement results and statistics from multiple locations in one central lab. By taking advantage of a direct Ethernet or a LIMS-connection, COCKPIT™ builds a bridge between the lab and Grabner vapor pressure testers in the field. Access via VPN tunnel adds an extra layer of security to the data transfer between Vision analyzers and COCKPIT™ software.
-
product
Gas Analysis
HPR-20 TMS
The Hiden HPR-20 TMS Transient MS is configured for fast event gas analysis of gases and vapours at pressures near atmosphere. Ideal for fast gas switching experiments the MS features the Hiden QIC quartz-lined 0.9 m sampling interface.
-
product
Vapor Source Mass Flow Controller With Viscous Choked Flow
The 1150C Vapor Source Mass Flow Controllers are pressure based measurement and control systems designed to meter and control vapor from low vapor pressure liquid and solid sources directly, without the need of a carrier gas using viscous flow through a choked orifice.
-
product
Gas Analysis
QGA
Hiden Analytical supplies precise and user-friendly tools for quantitative gas and vapour analysis. Our compact Hiden QGA system is a high performance gas analyser configured for real-time continuous monitoring of multiple species with an extremely wide dynamic range.
-
product
Permeation Analyzers
MOCON Permeation Analyzers are used to test the gas permeability of packaging films and whole finished packages. Our analyzers provide Oxygen Transmission Rate (OTR) and Water Vapor Transmission Rate (WVTR) testing capabilities for a diverse range of materials and packages. MOCON Water Vapor and Oxygen Permeation Analyzers offer the highest repeatability and lowest limits of detection for OTR and WVTR measurements. This means better QC of your packaging processes and higher confidence in your R&D results.
-
product
Residual Gas Analysis
Systems for the examination of components present in a vessel or evolved from a process.Measures the concentration of gases and vapours in real time.
-
product
Dual Vapor Gravimetric Sorption Analyzer
DVS Resolution
DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.
-
product
Fume Hood Controller
FHC50-01
Fume hoods are a primary source of protection in laboratories. Face velocity measurements are often used to gauge the performance of a fume hood’s ability to contain and exhaust harmful vapors. By measuring and controlling face velocity, TSI FHC50 Fume Hood Controllers provide a higher level of fume hood safety and energy efficiency.
-
product
Temperature
NOSHOK’s Temperature Measurement Solutions include bimetal thermometers, vapor actuated remote thermometers, digital temperature indicators, probe type RTDs, RTD transmitters, temperature transmitters & switches, and thermowells. We also offer a variety of options and accessories such as stem types, connections, special dials and lenses, certified calibration and RTD terminal blocks.
-
product
Adaptive Infrared Imaging Spectroradiometer
AIRIS
The Adaptive Infrared Imaging Spectroradiometer (AIRIS) has been developed for real-time standoff detection of chemical vapors and biological aerosols as well liquids and solids (such as chemical agents and trace explosive residues) on surfaces.
-
product
Gas Filter Correlation CO Analyzer
Model N300
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
product
Principle Of MALDI/TOFMS
MALDI is the abbreviation for "Matrix Assisted Laser Desorption/Ionization." The sample for MALDI is uniformly mixed in a large quantity of matrix. The matrix absorbs the ultraviolet light (nitrogen laser light, wavelength 337 nm) and converts it to heat energy. A small part of the matrix (down to 100 nm from the top outer surface of the Analyte in the diagram) heats rapidly (in several nano seconds) and is vaporized, together with the sample.
-
product
Halogen Moisture Analyzers
Halogen Moisture Analyzers determine the initial weight of the sample. The sample is quickly heated by the internal halogen dryer unit causing moisture to vaporize. During the drying operation, the instrument continuously determines the weight of the sample and displays the loss of moisture.
-
product
Adsorption Analyzers
These compact, fully automatic analyzers measure high-resolution physisorption, chemisorption, and vapor sorption isotherms for pore size, surface area, and specific gas/solid interactions. All these parameters are essential for the optimization of a wide range of materials, including adsorbents, catalysts, pharmaceuticals, battery materials, and other porous solids.
-
product
Portable Spectrometer / Portable Spectrum Analyzer
Optoplex's portable spectrometer / portable near-infrared optical spectrum analyzer (OSA) / mini spectrometer is a valuable spectral module in the Process Analytical Technology (PAT) applications. Portable spectrometer acts as a stand-alone spectral engine, imaging and measuring, through a rapid and nondestructive process, a wide range of vapor, liquids and solids through transmission and diffuse reflection.
-
product
Water Vapor Desorption Products
RBD's vacuum chamber water vapor removal products include high-power, high temperature IR radiant bakeout emitters, and low-power, low temperature UVC emitters.
-
product
Process Gas Condenser/Chiller
Process gas chillers are designed to condense vapors out of a process gas stream so it may be collected and properly disposed.This chiller condenses Styrene (a gas that is regulated by the E.P.A.) out of a process gas stream. The chiller operated continuously at a -25C (-13F) outlet air temperature as long as the process gas stream was flowing.
-
product
Water Vapour Permeability Tester
TF165B
TESTEX Testing Equipment Systems Ltd.
Water Vapour Permeability Tester, to determine the resistance of textiles and textile composites (particularly action wear fabrics) to water vapour penetration. Water Vapour Permeability Tester complies with BS 3424/7209, etc.
-
product
Sunphotometers
SP02 & SP02-L
The Middleton Solar SP02 Sunphotometer is a simple low-cost instrument for the determination of the spectral optical depth of the atmosphere. It can be configured for total & aerosol optical depth measurement, column ozone measurement, and assessment of water vapour amounts. It consists of four precision spectro-pyrheliometers axially aligned in a sealed enclosure.
-
product
Trace Gas Analyzers
Campbell Scientific offers both open-path and closed-path trace gas analyzers for measuring carbon dioxide and water vapor. Campbell Scientific also offers a closed-path analyzer for measuring methane, nitrous oxide, or isotopologs of carbon dioxide.





























