Showing results: 121 - 135 of 210 items found.
-
Elcometer Limited
This range of telescopic probe handles and extension rods allow you to test out of reach areas.
-
Elcometer Limited
Measurement parameters include:*Surface assessment*Blast equipment inspection*Surface profile*Surface contamination
-
Elcometer Limited
Blasting parameters: A number of important parameters need to be monitored during the blasting or water jetting process, these include: air pressure (at the nozzle), nozzle diameter, blast media contamination & pH values in order to avoid recontamination of the substrate during blasting.
-
Elcometer Limited
Supplied with either standard cables or armoured metal reinforced heavy duty cables, Elcometer convex surface profile probes are supplied with a glass zero tile, calibration test foils (nominal values 125μm (5.0mils) & 508μm (20mils)) and an Elcometer test certificate.
-
Elcometer Limited
Supplied with either standard cables or armoured metal reinforced heavy duty cables, Elcometer surface profile probes are supplied with a glass zero tile, calibration test foils (nominal values 125μm (5.0mils) & 508μm (20mils)) and an Elcometer test certificate.
-
ASTM D4940 -
Elcometer Limited
Testing abrasives on site for soluble salt contamination can be carried out quickly and easily using the Elcometer 138 Abrasive Soluble Salt Test Kit, according to the ASTM D4940 method.
-
Elcometer 138 -
Elcometer Limited
Incorporating a flat sensor, the Elcometer 138 Bresle Salt Meter measures the conductivity of a sample, then automatically converts this to show the density of salts, negating the need for the user to do a manual calculation when working in accordance with ISO 8502-6 or ISO 8502-9.
-
Elcometer Limited
The Elcometer 135C Bresle Test Patches determines the concentration of soluble salts on uncoated surfaces in accordance with the ISO 8502-6 test method.
-
135B -
Elcometer Limited
Elcometer 135B Original Bresle Patches are used to determine surface chloride contamination and are self-adhesive rubber film patches with a sealed compartment for sampling soluble impurities from steel surfaces with a suitable solvent.
-
145 -
Elcometer Limited
The Dust Tape Roller presses the Elcometer 142 Dust Tape to the surface using a controlled constant force as required by BS EN ISO 8502-3 (BS 7079-B3:1993).
-
155 -
Elcometer Limited
This enables the application system to be set up and fine tuned prior to the curing process. In turn, this will reduce the amount of scrap and over-spray.Place the comb into the powder and slide the comb along the surface. The measurement points (or teeth) are pointed and allow the powder to flow around them.
-
3230 -
Elcometer Limited
By rolling the gauge through a wet coating, the centre wheel eventually touches the film. This point on the scale indicates the thickness.
-
Elcometer 115 -
Elcometer Limited
Four separate thickness ranges are available up to a maximum of 1,250μm or 50mils and are manufactured to an accuracy of ±5% of marked value or ±3µm (0.12mil), whichever is greater.
-
3238 -
Elcometer Limited
Each comb has 24 measurement steps (teeth) providing a more accurate wet film thickness value.
-
Elcometer 3230 -
Elcometer Limited
The outer wheels are knurled to allow measurements to be taken on slippery coatings or on fast moving substrates.