Showing results: 121 - 135 of 346 items found.
-
LS-80 -
Standard Electric Works Co., Ltd
● Easy to read long-scales and pointer-indications can easily be read from a distance.● Full Scale Deflection:250°● Accuracy: Class 1.5● Scale Length :140 mm● Case and Composition: Polycarbonate window, plastic body and terminal, Four studs mounting.● Color:White scale plate, black terminal plate, black meter body.● Pointer:Sword-type in black color.
-
LVD-15 -
Standard Electric Works Co., Ltd
● Bright LED and audible alarm sound when voltage is present.● Designed for non-contact voltage detection.● Can be used to find a break in a wire.● Flashlight function.● ON/OFF switch for longer battery life.
-
1154 TMF-M -
Standard Electric Works Co., Ltd
● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● BS 16 edition.
-
1824 LP -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays voltage supply at the transformer(Line to Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.
-
ST-123U -
Standard Electric Works Co., Ltd
● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.
-
8052 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on “low ohms” : 3Ω & 500Ω.● AC voltmeter with linear scale up to 600 Vac.● 200mA short circuit current for continuity.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display of external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Supplied with high quality test leads.
-
ST-95 -
Standard Electric Works Co., Ltd
● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : ± 2.0% full scale● Case and Composition: ABS case and PC cover Four studs mounting● Accuracy : ± 2.0% full scale value● Color:Black case and white scale plate.● Pointer:Knife-type, color in black.
-
ST-90U -
Standard Electric Works Co., Ltd
● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.
-
6280 TB -
Standard Electric Works Co., Ltd
● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1
-
2801 IN -
Standard Electric Works Co., Ltd
● Microprocessor-controlled with advanced safety features.● Three test voltages : 250 / 500 / 1000V.● Displays and sound warning if external voltage present.● Ener-Save™ feature to extend battery life.● Continuous battery monitoring.● Auto ranging / auto-null / auto-off.● Insulation tested at 1mA.● Built-in carry case, test leads in separate pouch.● Real-time barg-raph display of test voltage and voltage decay during discharge.● Audible and visual message displayed if external voltage is present.● Large LCD.● Display can be customized for special orders.● Continuity buzzer.● Show test time duration (up to 99.9s) for easy comparison.● BS 16 edition.
-
ST-2001 ACV -
Standard Electric Works Co., Ltd
● Big-size LCD (112 x 59mm)● Backlight function.● Analog scale with Bar-graph for viewing. (100 bars)● 10000 counts (high resolution).● DCV Ranges: 99.99mV~999.9V (ST-2001 DCV). ● ACV Ranges: 99.99mV~800.0V (ST-2001 ACV). ● 5 manual ranges controlled by rotary switch.● Data Hold function● Low battery indication● 9V power supply● Best resolution of 0.01mV (10uV)● Precision meter for factory maintenance, field servicing and educational purposes.● With an optical USB to RS-232 data transmission cable. (DCV-R & ACV-R)● 2 optical LEDs are built-in for data transfer. (DCV-R & ACV-R)● Well isolated to contact. (DCV-R & ACV-R)● The software is included (Compact disc). (DCV-R & ACV-R)
-
4310 IN -
Standard Electric Works Co., Ltd
• Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display
-
-
-
285 HD -
Standard Electric Works Co., Ltd
● Three different ranges of identification of AC voltage: 285-A HD : 3~7 kV 285-B HD : 6.6~11 kV 285-C HD : 10~22 kV● The LCD will "flash continuously" for high voltage testing.● Physical contact with electrical conductors is not nec- essary when testing for live wires.● The 285 HD senses the radiated field that surrounds live conductors.● Radiated field strength increases with voltage and decreases quickly with distance.● Large LCD.● Continuous monitoring.● Easy to install.● No batteries required.● Weight : Approx. 80g.● Meets EN 61326-1 EN 55011 EN 61000-4-2 EN 61000-4-3