Showing product results. 76 - 90 of 302 products found.
-
HS6-DIFF-50XMG-W5 - TEAM SOLUTIONS, INC.
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
HS6-DIFF-1000XMSG-W5 - TEAM SOLUTIONS, INC.
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
HS6-DIFF-200XMSG-W5 - TEAM SOLUTIONS, INC.
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.-SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
HS6-DIFF-500XMSG-W5 - TEAM SOLUTIONS, INC.
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.-SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
HS6-DIFF-50XMSG-W5 - TEAM SOLUTIONS, INC.
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.-SureConnect, auto-detects a true connection between probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
HS6-DIFF-100XMSG-W5 - TEAM SOLUTIONS, INC.
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
HS6-DIFF-100XMS-W5 - TEAM SOLUTIONS, INC.
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
HS6-DIFF-200XMS-W5 - TEAM SOLUTIONS, INC.
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
HS6-DIFF-500XMS-W5 - TEAM SOLUTIONS, INC.
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
HS6-DIFF-50XMS-W5 - TEAM SOLUTIONS, INC.
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
TP450-250XM-W5 - TEAM SOLUTIONS, INC.
The Handyscope TP450 is a power quality analyzer, connected via USB to the computer. The advanced measurement software delivered by default contains Quick Setups that allow to start mains power logging measurements without specialized instrument knowledge. With the 450 V input range, the Handyscope TP450 can be plugged directly in a (110 - 230 V) wall socket to measure the mains voltage. No additional attenuator is required. Logging mains voltage can be done at a high rate of 250 thousand measurements per second, with a resolution of 16 bit, which is equal to a 5½ digit voltmeter. The Handyscope TP450 is an accurate voltmeter, but one that performs 5000 measurements on each cycle of the mains voltage, while a standard voltmeter performs 3 measurements per second. Even with the very high measurement rate of the Handyscope TP450, the mains voltage can be measured continuously for weeks, and afterwards each period of the mains voltage can be analyzed thoroughly. Using this fast continuous measuring method, no voltage peak or dip is missed, even if it lasts just a msec. The maximum measuring duration of the mains voltage is only limited by the available hard disk space. Measuring one week takes approximately 0.69 GB disk space. During a measurement, also RMS value and frequency are logged. It is possible to measure various properties, like e.g. Minimum, Maximum, Peak to peak, Mean, Variance, Standard deviation.
-
TP450-50XM-W5 - TEAM SOLUTIONS, INC.
The Handyscope TP450 is a power quality analyzer, connected via USB to the computer. The advanced measurement software delivered by default contains Quick Setups that allow to start mains power logging measurements without specialized instrument knowledge. With the 450 V input range, the Handyscope TP450 can be plugged directly in a (110 - 230 V) wall socket to measure the mains voltage. No additional attenuator is required. Logging mains voltage can be done at a high rate of 250 thousand measurements per second, with a resolution of 16 bit, which is equal to a 5½ digit voltmeter. The Handyscope TP450 is an accurate voltmeter, but one that performs 5000 measurements on each cycle of the mains voltage, while a standard voltmeter performs 3 measurements per second. Even with the very high measurement rate of the Handyscope TP450, the mains voltage can be measured continuously for weeks, and afterwards each period of the mains voltage can be analyzed thoroughly. Using this fast continuous measuring method, no voltage peak or dip is missed, even if it lasts just a msec. The maximum measuring duration of the mains voltage is only limited by the available hard disk space. Measuring one week takes approximately 0.69 GB disk space. During a measurement, also RMS value and frequency are logged. It is possible to measure various properties, like e.g. Minimum, Maximum, Peak to peak, Mean, Variance, Standard deviation.
-
GPIB-PCI-E - TEAM SOLUTIONS, INC.
The Windows software set is included with the GPIB card. It is a WDM driver and supports Windows XP/2k/Vista/7/8 (32- & 64-bit 7 & 8), on all PC compatible platforms. Libraries and header files are included for the Visual C++, Visual Basic, MINGW and Delphi development systems. An industry standard compatible GPIB-32.DLL supports nearly all applications designed for that interface, including applications developed for LabView 6+, LabWindows, Agilent VEE, TransEra HT-Basic, Agilent Intuilink, and more.
-
GPIB-PCMCIA-XL - TEAM SOLUTIONS, INC.
The GPIB-PCMCIA-XL is the ideal solution for connecting GPIB instruments to mobile computers.
-
GPIB-PCI-XL - TEAM SOLUTIONS, INC.
The GPIB-PCI-XL is a PCI GPIB controller card that converts any PC with a PCI bus slot into a GPIB controller.