Teledyne Advanced Pollution Instrumentation

Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.

  • (858) 657-9800
  • (858) 657-9818
  • api-sales@teledyne.com
  • 9970 Carroll Canyon Road
    CA, San Diego 92131
    United States

Filter Results By:

Products

Applications

Showing results: 46 - 60 of 70 items found.

  • Carbon Compound Instruments

    Teledyne Advanced Pollution Instrumentation

    Teledyne API's Carbon compound analyzers utilize Gas Filter Correlation combined with reliable NDIR (non-dispersed infrared) technology to produce very stable and accurate gas measurements. ​All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.​

  • Gas Calibrators and Zero Air Generators

    Teledyne Advanced Pollution Instrumentation

    All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.

  • Sulfur Compound Instruments

    Teledyne Advanced Pollution Instrumentation

    Teledyne API's Sulfur compound analyzers utilize familiar UV Fluorescence technology to produce​ reliable and accurate gas measurements. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.

  • Mid-Range Gas Filter Correlation CO2 Analyzer

    Model N360M - Teledyne Advanced Pollution Instrumentation

    The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • Mid-Range Gas Filter Correlation CO Analyzer​

    Model T300M - Teledyne Advanced Pollution Instrumentation

    The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.

  • Oxygen Compound Instruments

    Teledyne Advanced Pollution Instrumentation

    Teledyne API’s range of instruments for Oxygen compounds utilize advanced technology to produce some of the most accurate measurements available.All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.​​

  • Portable Trace-Level O3 Calibrator​

    ​Model T753U - Teledyne Advanced Pollution Instrumentation

    The Model T753U is a portable, microprocessor based precision Calibrator for Ozone gas instruments and sensors. Using a sophisticated Ozone generation system, combined with a sensitive photometer and pneumatic design, the T753U produces stable and reliable concentrations of Ozone in a convenient and rugged package based on our popular T750U Portable Multigas Calibrator platform. The T753U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field for virtually any application. An internal zero air option extends the T753U's capabilities to also provide a clean and dry source of zero air, eliminating the need for a separate source of zero air. The internal zero air source module contains a software driven electronic inlet valve manifold allowing the calibrator to automatically switch between internal and external zero air sources depending on the application needs.​

  • Zero Air System

    ​Model N701 - Teledyne Advanced Pollution Instrumentation

    The N701 is a fully self-contained source of clean, dry air for dilution calibrators. It can also simultaneously be used as a pressure source for activating instrument pneumatic valves and/or purge air for permeation tube ovens. The N701 includes a dewpoint sensor, an oil-less and diaphragm-free pump, and scrubbers to remove SO2, NO, NO2, O3, H2S, and NH3. An optional high performance heated converter is available for effective removal of Carbon Monoxide (CO) and Hydrocarbon gases.

  • Mid-Range Gas Filter Correlation CO2 Analyzer

    Model T360M - Teledyne Advanced Pollution Instrumentation

    The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.

  • Gas Filter Correlation CO Analyzer

    Model T300 - Teledyne Advanced Pollution Instrumentation

    DescriptionFeaturesSpecificationsApplicationsDownloadsMaintenanceThe Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.

  • Gas Filter Correlation CO2 Analyzer

    ​Model N360 - Teledyne Advanced Pollution Instrumentation

    The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • High Range UV Fluorescence SO2 Analyzer

    Model T100H - Teledyne Advanced Pollution Instrumentation

    The Model T100H SO2 analyzer uses the proven UV fluorescence principle with the high measurement ranges and interferent rejection needed for extractive source monitoring. The Model T100H provides a simple but precise solution for a broad range of CEM and stack testing applications.The instrument design provides minimal quenching by O2 or CO2 and less than a 0.1% response to water in the sample. Additionally, special optical filtering reduces the effects of NO interference.

  • High Range UV Fluorescence SO2 Analyzer

    Model N100H - Teledyne Advanced Pollution Instrumentation

    The Model N100H instrument uses the proven UV fluorescence principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of high range SO2 gas. The instrument includes interferent rejection, providing a simple and precise solution for a broad range of continuous emission monitoring systems (CEMS) and stack testing applications.

  • Mid-Range Gas Filter Correlation CO Analyzer

    Model N300M - Teledyne Advanced Pollution Instrumentation

    The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.

  • Gas Filter Correlation CO​​​​ Analyzer

    ​Model N300 - Teledyne Advanced Pollution Instrumentation

    The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.

Get Help