CT-7000 S3 -
Manta Test Systems
The CT-7000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-7000 S3 is available with 3 (part number 9021-UC) or 6 contact timing channels (part number 9100-UC). The CT-7000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Both contact and motion analysis can be performed on all circuit breaker operations (OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, and OPEN CLOSE-OPEN). The CT-7000 S3’s timing window is selectable between 1 second, 10 seconds, and 20 seconds.
-
CT-8000 S3 -
Manta Test Systems
The CT-8000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-8000 S3 is available with 3 (part number 9103-UC) or 6 contact timing channels (part number 9104-UC). The CT-8000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Also, an outstanding feature of the CT-8000 S3 is the ability to perform dynamic resistance tests on circuit breaker contacts.
-
CT-3500 S2 -
Manta Test Systems
The CT-3500 S2 is Vanguard’s second generation, stand-alone, digital, microprocessor-controlled, circuit-breaker timer. It measures the elapsed time from the instant a breaker coil is energized to the instant of opening or closing of a circuit-breaker’s dry contacts. In addition to timing a breaker’s contact response time, the CT-3500 S2 can also time relays or other switching functions that use an initiating trigger voltage (24-300 Volts DC or AC). The timer-triggering voltage starts three independent electronic timers. Each timer is individually stopped by its respective dry-contact closing or opening. The CT-3500 can fully analyze the timing of all circuit breaker operations (Open, Close, Open – Close, and Close – Open). Timing results are displayed in milli-seconds and cycles on the unit’s back-lit LCD screen and can be printed on the built-in 2.5-inch wide thermal printer.
-
F6880 -
Manta Test Systems
The Doble F6880 Digital Network Analyzer (DNA) reveals details that are essential to helping protection engineers and relay test technicians quickly resolve issues in IEC 61850 network traffic.
-
UPS S3 -
Manta Test Systems
The Vanguard UPS S3 is an AC/DC adjustable output power supply designed to operate substation circuit breakers. The UPS S3’s AC and DC voltage sources can supply up to 10 Amperes during the circuit breaker coil energization and circuit breaker charging motor operation. Powered by a single phase 90-120 Vac voltage source, the UPS S3 provides an isolated adjustable AC/DC voltage source. Output voltages are variable via the front panel control knob.
-
Myrkos -
Manta Test Systems
To make informed decisions on site, you need fast and reliable data. Myrkos portable gas analyzers provide laboratory quality DGA data where you need it, when you need it. In remote locations, to confirm monitoring data, or whenever on-site diagnosis is required, Myrkos portable gas analyzers provide results as accurate as a lab through our proprietary Shake Test® syringes.
-
DOMINO USS -
Manta Test Systems
The Doble DOMINO USS (Ultimate Sampling System) gives you a fast, efficient way to measure water content in oil and/or the dewpoint of a gas.
-
F6150sv -
Manta Test Systems
This power system simulator performs the simplest through the most complex tests. The F6150sv has the highest output current of any test set on the market – all within a single box.
-
CBCT -
Manta Test Systems
The CBCT is a variable voltage DC power supply designed specifically to test substation circuit-breaker Open and Close coils. The CBCT uses the substation’s DC power supply to electronically generate a programmable output voltage from 5% to 95% of the source voltage. The CBCT can maintain up to an 80A test current while maintaining 2% or better voltage regulation during the circuit breaker coil operation.
-
MTS-5100 -
Manta Test Systems
The MTS-5100 is the only all-in-one relay test set with a direct front panel interface for all functions, without exception!
-
UPS S2 -
Manta Test Systems
The Vanguard Universal Power Supply Series 2 (UPS-S2) is designed and produced to meet a utility company’s substation needs for an independent AC/DC power source. Both the AC and DC Voltage sources are capable of supplying 10 amperes continuously.
-
DMOM-600 -
Manta Test Systems
The DMOM-600 is specifically designed for testing EHV circuit-breaker contact resistances, bushing contact joints, welding joints, or for any low-resistance measuring application. This high current and very lightweight (33 lbs/ 15 Kg) micro-ohmmeter is designed to meet the IEEE C57.09-1999 (5.15) requirement for testing circuit breaker contact resistance.
-
SGT-200 -
Manta Test Systems
The Vanguard SGT-200 Safety Ground Tester is a 200A DC micro-ohmmeter designed specifically to measure the resistance of protective in-service grounding and jumper cable assemblies. The SGT-200 can measure the resistance of the grounding cables, clamps and ferrules. The measured resistance values can be compared against the calculated values (using the ASTM 2249-03 standard) and a Pass/Fail result can be printed along with the measured resistance values. Since the SGT-200 uses a DC current, there is no need to uncoil the cable under test. It can be conveniently tested in its coiled state in a much smaller testing enviornment.
-
MCCB-250 -
Manta Test Systems
The Vanguard MCCB-250 is a programmable, high-current source designed specifically for testing molded-case circuit breakers, thermal magnetic and solid-state overload motor-protection relays.
-
TDR9100 -
Manta Test Systems
The Doble TDR9100 Circuit Breaker Analyzer is a state-of-the-art circuit breaker test set for testing all types of circuit breakers with efficient and accurate performance measurements.