Showing results: 2011 - 2025 of 5211 items found.
-
Weshine Electric Manufacturing Co., Ltd
The induction withstand voltage test of transformers and transformers is an important test to ensure that the quality of transformers conforms to national standards. The longitudinal insulation induction withstand voltage test of the inter-turn, inter-layer, inter-section and inter-phase insulation of the transformer winding is an important item in the transformer insulation test.
-
SKZ130 -
SKZ Industrial Co., Ltd
Used for the determination of the abrasion resistance of the test piece. Friction hammer reciprocating movement, specimen clamping on the test bench by the weight increase generated frictional resistance, During the test by automatic counting counter and display, the number reached the set, automatic shutdown.
-
MS-139 -
Misum Systech Co., Ltd.
This equipment is used for inspecting the current, voltage and temperature of Smart Module in lap top battery. It can do EEPROM data read / verify.
-
Weshine Electric Manufacturing Co., Ltd
The DC test method is adopted to simulate the actual use of the battery in a real and objective way, which can effectively eliminate the hidden dangers such as deficiency, deficiency and connection failure between batteries while measuring the internal resistance of the battery.
-
Weshine Electric Manufacturing Co., Ltd
1. The instrument has an automatic measurement function.2. The instrument has a perfect back-EMF protection function.3. The instrument uses a 5-inch 65K color LCD touch screen, which is easy to operate.
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
MDPPTSTUSB -
Matco Tools
*Provides the user with a simple way to test a USB socket on a vehicle*Mini probe will light up when 4.4V - 5.25V is detected
-
King Design Industrial Co., Ltd.
*Spectrum mis-match: IEC 60904-9 class A*Non-uniformity <5%*Instability <5% ( within 30 mins)*Irradiance range: 800 W/m2 ~ 1200W/m2*Effective range: 30cm x 30cm; 1.1m x 1.4m*(customize accepatble)*Temperature:40℃ ~ 90℃*Humidity: 20% ~ 85%
-
Compliance West USA, Inc
designed to perform the 60 Hz power line cross test/AC power fault tests required in GR 1089 issue 6 table 4.5 surge test 3,4, 4.3,and 6, and for UL 1950 section 6.4 paragraph 3 and 4.. Preset and Adjustable Time Settings Measuring Terminals including Voltage Sense and Current Shunt portals provide a safe location for users to accurately measure test voltages and output current while setting up tests. Calibration of the Mini_PT-600 is designed to be performed with a simple handheld multi-meter and the removable Currents Shunts can be easily sent to a calibration laboratory if required.
-
Sheen Instruments
Using the magnetic attraction principle, this traditional gauge offers reliable thickness measurement of coatings, electroplating, enamel, rubber, electroplated nickel on steel, or electroplated nickel on non-ferrous substrates.
-
Pilot 4D V8 -
SEICA SpA
The Pilot 4D V8 represents the latest frontier in flying probe test technology; it is the complete solution for those who want maximum performance: the highest test speed, low to medium volume, test coverage and flexibility, for prototyping, manufacturing, or repairing any type of board. Its vertical architecture is the optimum solution for probing both sides of the UUT simultaneously.
-
TN130 -
TESTEX Testing Equipment Systems Ltd.
A piece of standard absorption media is placed under and the specimen, the combined sample are placed in a tilted pad, measuring when a specific amount of artificial urine to flow downward to the combined sample, the liquid penetrate nonwovens and be absorbed by absorption medium. Weigh the standard absorption media before and after test, the performance of fluid loss of nonwoven samples is evaluated according to the change of the weight of the absorption media
-
DE-5030 -
DER EE Electrical Instrument
Earth resistance range0~12 / 0~120 / 0~1200 Normal operation conditionsBattery voltagein range of "BATT.GOOD" Earth voltage measurementmax. AC 30V Output current3mA Response timewithin 1 sec. Insulation resistancemin. 100M / DC1000V between input terminals and case Withstand voltageAC3700V (50 / 60Hz) for 1 min. between input terminals and case Battery Check Battery1.5V x 4 Safety standardIEC 61010-1 CAT.III 300V IEC 61557, IEC61010-031
-
29500 -
Lisle Corp.
The low-side checks AC and DC current up to 28 volts with power on. The high-side checks spark plug wires without piercing. Complete with insulated clip.
-
DZ900S -
Shanghai Aoboor Electric Co., Ltd.
Test objects include stators for single-phase AC motors. three-phase AC motors, servo motors, stepper motors, brushless motors series excitaion motors, hub motors, shaded pole motors as well asspecial winding stators.