Showing results: 1 - 8 of 8 items found.
-
VX2745 -
CAEN S.p.A.
The VX2745 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64X form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.
-
V2740 -
CAEN S.p.A.
The V2740 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64 form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.
-
V2745 -
CAEN S.p.A.
The V2745 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64X form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.
-
VX2740 -
CAEN S.p.A.
The VX2740 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64X form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.
-
Hexagon Family -
CAEN S.p.A.
Hexagon is a high precision 32k MCA available in single and dual input channel versions. This compact, high performance desktop MCA includes features such as an input stage for signal conditioning, a fast analog-to-digital converter (ADC), digital signal processing algorithms, High Voltage and Preamplifier outputs for detector bias and preamp power. Hexagon is ideally suited for applications using high energy resolution semiconductor detectors such as HPGe, Silicon, CZT as well as scintillation detectors such as NaI and LaBr3. It can manage both positive and negative signals from resistive feedback or transistor reset preamplifier detectors as well as signals coming from PMT anodes.
-
Gamma Stream Family -
CAEN S.p.A.
CAEN Gamma stream is a compact and portable system for gamma ray spectroscopy with scintillation detectors, which provides an active Multi-Channel Analyzer (MCA) integrated in a 14-pin photo-multiplier tube (PMT) base. Gamma stream fully integrates in a stand-alone device the high voltage to bias the PMT, the preamplifier to shape the signal from detector, and the MCA for a complete Pulse Height Analysis online.
-
2740 Family -
CAEN S.p.A.
The 2740 Digitizer is a 64-channel digital signal processor for radiation detectors available in VME64 (V2740), VME64X (VX2740), and Desktop (DT2740) form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others. The 2740 can perform pulse height measurements (PHA), constant fraction timing (CFD), charge integration (QDC) and pulse shape discrimination (PSD) independently for each of the 64 channels.
-
2745 Family -
CAEN S.p.A.
The 2745 Digitizer is a 64-channel digital signal processor for radiation detectors available in VME64 (V2745), VME64X (VX2745), and Desktop (DT2745) form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others. The 2745 can perform pulse height measurements (PHA), constant fraction timing (CFD), charge integration (QDC) and pulse shape discrimination (PSD) independently for each of the 64 channels.