Product
Microphone Preamplifier
426A11
-
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
Product
Microphone Preamplifier
426A30
-
1/2-inch preamplifier with 7-pin LEMO connector (for externally polarized microphones)
-
Product
Microphone preamplifier
PRE-01
-
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
Product
USB Microphones
-
Easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic Is esignals with the highest quality.
-
Product
Microphone Preamplifier
426B03
-
Performance: Nominal Microphone Diameter:1/4"Frequency Response: (0.1 dB) (re 1 kHz)5 to 126000 Hz5 to 126000 Hz Frequency Response
-
Product
Omni Measuring Microphone
PVR™ 2
-
Omni-directional microphone for free-field measurement. With a highly reliable circuit and a 1/4" pre-polarized condenser capsule, it boasts high stability, low distortion and low noise in performance. Its excellent flat frequency response makes it ideal for sonic analysis systems and recording.
-
Product
ICP Electret Surface Microphone
130B40
-
Low-profile surface pressure microphone and preamp, prepolarized
-
Product
Laser Levels
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
UYIGAO laser level is a construction tool which measures levelness by projecting a red or green light beam onto a flat surface. Laser levels are used to deduct how level or straight a surface is by projecting a light beam across or around it.
-
Product
Precision Condenser Microphone
2575
-
Performance:Nominal Microphone Diameter1"1" Frequency Response: Characteristic (at 0 incidence) Random IncidenceRandom Incidence Open Circuit Sensitivity: 45 mV/Pa Resonant Frequency (90 Phase Shift)8000 Hz8000 Hz[1] Inherent Noise<10 dB(A) re 20 Pa<10 dBTemperature Range (Operating)TBD FTBD C Humidity Coefficient of Sensitivity (0 to 95%, non-condensing)0.001 dB/%RH
-
Product
ICP Electret Array Microphone
130A23
-
Nominal Microphone Diameter: 1/4" Frequency Response Characteristic (at 0 incidence)Free-FieldInherent Noise (A Weighted)<30 dB(A) re 20 Pa<30 dB(A) re 20 Pa Dynamic Range (High)150Environmental Temperature Range ( Temperature Effect on Output (-10 to +50 C)<0.7 dB<0.7 dB[2] Influence of Axial Vibration Excitation Voltage 18 to 30 VDC18 to 30 VDC
-
Product
Precision Condenser Microphone
378A12
-
1/4-inch pressure prepolarized 377A12 microphone, with 1/4-inch preamplifier 426B03 and TEDS v0.9
-
Product
Phantom Powered Measurement Microphone System
7052PH
-
The 7052PH Type 1.5TM phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Type 1.5TM - a superior Type 2. Frequency Response: <3 Hz to > 20kHz typ.(capsule). Sensitivity: 22 mV/Pa (-33 dBV/Pa)typ. Dynamic Range (capsule) 1% THD: <20dBA-150dBSPL (Capsule).
-
Product
30KHZ Measurement Microphone
M30
-
Used on countless full-scale concert tours, as well as in scientific research laboratories, tropical rainforests, and rocket testing facilities, the M30 has proven to be a lab-grade audio instrument that can handle any environment.
-
Product
Level Controllers
-
Measure and control fluid levels in a contained area or facilitate automatic filling and emptying operations with Omega's dependable single and multi-sensor level controllers.
-
Product
Microphone Pre-Amp Audio Interfaces
-
Analog Devices mic pre-amp audio interfaces provide a high fidelity, high performance solution for audio products. Specifications for this family include ultralow 1.5 dB noise figures, 140 dB gain range, and high gain capability. Operating in an extended industrial temperature range of –40°C to +85°C, this portfolio of mic pre-amp audio interfaces supports many applications, including precision instrumentation, active filters, low noise amplifier front ends, surveillance systems, computerized voice recognition, and a variety of other industrial and consumer products. As the first choice for serious audio engineers, Analog Devices mic pre-amp audio interfaces can give your applications the performance needed to meet the most demanding specifications.
-
Product
Ultrasonic Level Measurement
-
Ultrasonic technology is a perfect choice for level applications that require low cost, non-contact measurement of liquids and slurries for level, distance, volume and open channel flow. These products have excellent accuracy and will handle measurements up to 30’.
-
Product
Water Level Instrument
-
HighReach Measuring & Controlling System Co.,Ltd
For long time measuring water depth(pressure) and temperature.
-
Product
Microphone Preamplifier
HT426E01
-
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
Product
Magnetostrictive Level Transmitter
DM231
-
The Drexelbrook DM231 is an explosion proof liquid level transmitter offering high accuracy measurements based on the magnetostrictive sensing technology.The DM231 comes with a Modbus RTU digital output (optional analog output converter available) for total level, interface level and temperature sensor outputs. Sensors are available in 316SS rigid designs with a choice of single or dual NPT mountings. Temperature sensors are evenly distributed over the active length of the rigid 316SS tube.Due to a wide selection of floats and mounting accessories this level transmitter fits virtually any application.The DM231 level transmitter is FM approved for Class 1 Div. 1, Zone 1 Explosion Proof hazardous area installations. It is easy to install and requires no calibration.
-
Product
Level Quadrant
LIQUA
-
F. W. Breithaupt & Sohn GmbH & Co.KG
*Clinometer with robust housing*Quick adjustment of circle with eccentric bush*Illumination of circle and level*Graduation 6400-*Scale interval 1-*Measuring range +1000- bis .600-*Accuracy ± 0,5-*Made in Germany
-
Product
Sound Level Meters
-
Precision Mastech Enterprises Co.
A portable, handheld instrument designed to measure sound pressure levels (SPL) in decibels (dB), simulating how the human ear hears.
-
Product
Level Measurement
Level Measurement
-
AMETEK Sensors, Test & Calibration
B/W Controls uses the same advanced magnetostrictive technology as in Gemco products providing high accuracy and reliability for continuous liquid level measurement.
-
Product
Sound Level Meter
DE-3301
-
LCD Display4 digits LCD DisplayLow Battery display on LCDMeasuring Range30~130dBFrequency WeightingA,CDynamic Range50dBFrequency Range31.5Hz~8kHzTime WeightingFast125 ms
-
Product
Sound Level Meters
-
Castle Group Ltd are a long standing leading manfacturer of noise measuring equipment, particularly Sound Level Meters for industrial noise monitoring. Our equipment is ideal for performing noise at work assessments to The Control of Noise at Work Regulations 2005.
-
Product
Special microphones
-
G.R.A.S. Sound & Vibration A/S
Special microphones are often required for applications where there are particular requirements regarding the methods of measurements and configurations
-
Product
Sound Level Meters
-
Complies with IEC 61672-1 class 2 standard, Measures Leq, MaxL, MinL, SPL, 64,000 Records Data Logger, PC interface
-
Product
Ultrasonic Level Transmitter
USonic
-
The Drexelbrook family of Ultrasonic technology level products offers an affordable two wire and line powered version for non-contact level measurement of liquids and slurries for level, distance, volume and open channel flow.Measurements of level, distance, volume and open channel flow is easily configured through the menu driven display. The Usonic level transmitter is offered with a two wire 4-20 mA, Hart output signal and is suitable for all Class I Div. 1, Zone 0, I.S. or XP locations. The bench configuration eliminates the need to move process material levels for calibration.