Filter Results By:

Products

Applications

Manufacturers

Magnetic Permeability

the ability to become magnetized.

See Also: Magnetic, Permeability, Magnetic Test, Magnetic Field, Magnetic Head, Magnetic Susceptibility, Magnetic Flux, Magnetic Stripe, H-field, Hysteresis


Showing results: 1 - 15 of 19 items found.

  • Magnetic Permeability Meter Ferromaster

    Stefan Mayer Instruments

    Instrument for easy measurement of the relative magnetic permeability µr of feebly magnetic materials and workpieces with a permeability between 1.001 and 1.999. The permeability is measured by touching the workpiece with the probe tip and reading the result from the display. Typical applications are: non-destructive testing of materials, e. g. quality control of stainless steel, material selection for electron-/ion-beam equipment, detection of material defects induced by mechanical or thermal stress.

  • Magnetic Field And Permeability Measurement

    MAGNETOMAT 1.790 - Foerster Instruments, Incorporated

    The MAGNETOMAT 1.790 is a measuring system for the precision detection of magnetic flux density and relative permeability. The MAGNETOMAT software is used for displaying the measured values and saving and exporting data. The wide range of probes facilitates optimal adjustment to the conditions of the application, such as the measurement of relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys. Further applications include the long-term monitoring of the magnetic environment, e.g. prior to installing magnetically sensitive devices, and the localization of ferrite enclosures in stainless steel and NE materials. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.

  • Magnetic Field and Permeability Measurement

    MAGNETOSCOP® 1.070 - Foerster Instruments, Incorporated

    The MAGNETOSCOP 1.070 is a portable magnetometer system with microprocessor and probes for measuring the magnetic flux density as an absolute or differential value (gradient). It has a USB port for simple data transfer and an SD card for saving measurement data and parameters. The measuring system also facilitates the recognition and saving of peak values and the adjustment of thresholds for limit values. The unit can be used for series and individual measurements. The data can be easily analyzed and documented with the PC software included in the scope of delivery. The MAGNETOSCOP 1.070 thus facilitates the portable and fast measurement of the relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys as well as the localization of ferrite enclosures. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.

  • Non Destructive Testing Relative Magnetic Permeability

    Keighley Laboratories LTD

    Now covered under our UKAS accreditation to include specifications such as BS 5884, ASTM A342 and A.U.W.E. 29108, Magnetic Permeability is the ability of a material to become magnetized. Carried out using both balance bridge and digital meters, available both in house and on site (Not UKAS accredited).

  • DC Hysteresis Graph

    DX-2012SD - Dexing Magnet Tech. Co., Ltd

    Automatic measurement on basic magnetization curve and magnetic hysteresis loop under static state of soft magnetic material, accurate measurement on static magnetic characteristic parameters such as initial permeability µi, maximum permeability µm, saturation magnetic induction Bs, remanence Br, coercive Hc and hysteresis losses Pu.

  • Magnetic Material Test Fixture

    16454A - Keysight Technologies

    The 16454A is designed for accurate permeability measurements of toroidal-shaped magnetic materials. Since the construction of this fixture creates one turn around the toroid (with no magnetic flux leakage), the need of winding a wire around the toroid is unnecessary. Complex permeability is calculated from the inductance with and without the toroid. When the E4991A/4291B with option 002 is used as the measurement instrument, direct readouts of complex permeability are possible. In addition, it is furnished with a small and a large fixture to adapt to a wide range of sizes.

  • AC Hysteresis Graph Test System

    DX-2012SA - Dexing Magnet Tech. Co., Ltd

    Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.

  • Magnetic Property Characteristics Measurement System (from 100kHz to 14GHz)

    KEYCOM Corp

    KEYCOM’s magnetic property characteristics measurement system delivers ideal measurement solutions for complex permeability μr''- jμr'''', ferromagnetic resonance relaxation coefficient α, resonant line width ΔH in wideband from 100kHz up to 14GHz.

  • Electrical Measurements Test

    Aero Nav Laboratories, Inc.

    The tests are performed to measure and collect data from electrical and electronic parts using various measurement methods including, but not limited, to the following: capacitance, resistance, winding resistance, insulation resistance, magnetic permeability, power input, and quality factor Q.

  • Zero Gauss Chamber

    IDR-800 - Integrity Design and Reseach Corp.

    Two cylindrical tubes are equal in length (12"), one is inside the other, both of them are closed at one end. At the other end, the inner tube is open (Radius=1").The cylindrical tubes are made from high permeability material.The magnetic field inside the inner tube is almost annulled.Optional use with the Geomagnetometer IDR-321 to provide a zero gauss (magnetic field-free environment) reference, enabling you to take absolute readings of the ambient magnetic field (the Earth's magnetic field is typically around 500 mG)

  • Test and Calibration

    Ferrites India

    Ferrites India offers testing of materials for measurement of their magnetic properties. These materials are in the shape of laminations, stacks, solid toroids, laminated toroids, solid rods or magnets. The testing can be done under wide range of frequency and test specifications and various magnetic properties like B-H Curve, Loss, Permeability, Coersivity, Remnancy, Saturation Magnetization are measured. The testing is done as according with ASTIM/IEC/IS standards.

  • CTGcalc™ Software

    Compass Technology Group, llc

    CTGcalc™ is a Windows application that sets up microwave network analyzers, acquires measured S-parameter data, and analyzes the acquired data for CTG’s various measurement fixtures. CTGcalc™ allows the user to extract complex dielectric permittivity, magnetic permeability, or sheet impedance of the measured specimens.

  • AC Hysteresis Graph Test System

    DX-2012M - Dexing Magnet Tech. Co., Ltd

    Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.

  • Epstein Tester

    VET-1608 - Veer Electronics

    VEER make Digital Epstein Tester VET-1608 is complete stand alone instrument to measure AC magnetic properties of electrical steel of all grade and gauges mostly. It refers ASTM-343 standard. It also refers IEC 60404-2 & IS:649. Epstein Frame method is standard & worldwide accepted method to test important magnetic parameters like Watt/kg, VA/kg, Magnetizing Force, Permeability, Form Factor etc on different induction.

  • Potential Transformer Test Set

    Supreme Instrument Laboratories

    The two voltage vectors, one from Standard Potential Transformer and the other from the Potential Transformer under test energies the high permeability magnetic core and then associated windings try to annual the residual magnetism which occurs due to error. The differential vectors will be proportional to phase error and ratio error magnitudes.