Showing results: 31 - 45 of 289 items found.
-
GT00YB00ZV -
GAO Tek Inc.
The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can store 3900 sets of data and enables online and real time monitoring, historical data inquiry, read, inquire storage, generation, and printing of a fitting curve. It is widely used in 380/220 power systems. It complies with IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ (600 V), and IEC61326 (EMC standard) safety codes.
-
MEWOI Electronics Co.,ltd
High Accuracy Clamp AC Leakage Sensor use permalloy magnetic cores, with small size, high accuracy, good stability, strong anti-interference ability characteristics. It is applied with double shield technology, which insure strong anti-interference ability.
-
ST-05 -
Criterion Instruments Limited
Safety Tester Model ST-05 is a test set for testing small equipment powered by 120V 60 Hz, from an approved U-ground source. Test also can be run on double-insulated tools an on appliances with two-pin parallel plugs.
-
-
M-1141XR -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Waveform display is possible with connection to a smartphone・Measurement data is to be accumulated in the server, and it is available for graph and CSV output・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency (fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight
-
SECULIFE UL Series -
GMC-I Messtechnik GmbH
The SECULIFE UL Series is specifically designed to test the electrical safety of all types of diagnostic ultrasound transducers, totally independent of the ultrasound machines on which they are typically used. Although the SECULIFE UL can be used on virtually any type of ultrasound transducer, it is especially recommended in the testing of TEE (Transesophageal Echocardiography) transducers prior to each use.
-
TH2686N -
Changzhou Tonghui Electronic Co., Ltd.
■ Test voltage: 0-200V, 0-500V ■ Voltage accuracy: 1% set value + 1 word ■ Measuring range: 10nA-19.99mA, resolution: 1nA ■ Current accuracy: 2% reading + 2 words ■ Intelligent type, microprocessor control
-
TH300-C32 -
Changzhou Tonghui Electronic Co., Ltd.
■ Standard 32-channel synchronous charging and discharging ■ Standard 32-channel scan test ■ Can be expanded to more channels according to actual needs ■ Basic accuracy 0.3%
-
TH2686C -
Changzhou Tonghui Electronic Co., Ltd.
■ Test voltage: 0-200V, 0-500V ■ Voltage accuracy: 2% set value + 2 words ■ Measuring range: 0-30mA, 10 gears ■ Current accuracy: 2% of reading +0.5 grid
-
MCL-400IR+ -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).
-
-
MLD-18 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・The LED will blink when detection leakage current exceeds AC 15mA.・Supports ELB with high-speed detection of 20ms.・The operating period is about one month, which is suitable for detecting intermittent leakage current.
-
-
IGR Series -
Jaeshininfo Co. Ltd
IGR Leakage Current Analyzer is invented as the world first, and also can measure Insulation Resistance (MO) without power cut-off. This patented instrument can analyze leakage current, and display Igr(resistive), Igc(capacitive), and Io(vector sum), Ground Insulation Resistance, and the phase angle between voltage and current. (IGR ELB) - Operates due to Igr. - Properly-operating in spite of IGC in digital era. ( Not tripping on UPS load and Harmonics and noise area) - Possible to go down Igr for safety of people and animals. - Possible to manufacture high sensitive ELB. - Possible to prevent fire from electric leakage current.
-