BTAS-16 -
JFM Engineering
The task of testing an aircraft’s Nickel-Cadmium batteries is complicated and involved because of the high number of cell voltage readings that need to be taken during testing. Taking voltage readings from all 20 cells in the typical nickle-cadmium aviation battery multiple times is laborious and error prone, but must be done to properly estimate the condition of the battery under test.
-
KAL1000 Series -
Dr. Strauss Messtechnik GmbH
The impulse calibration system KAL1000 is a modular system to perform tests on complete impulse voltage measuring systems and on digital recorders for the measurement of high impulse voltages and impulse currents. The modular design allows an optimal KAL-configuration depending on the actual application.Additional, this modularity allows to up-grade or modify and existing KAL1000 system in case of changing or additional requirements
-
STG 600 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR STG 600. The STG 600 surge and test generator is a multifunctional cable fault locator for low voltage networks. The surge and test generator is used for cable testing as well as for precise location of high-resistive and intermittent faults in low voltage cables.* Specifically for use in low-voltage networks* High surge energy: 600 or 1000 J** Light, compact and transportable* Single systems for cable testing and faults location
-
CV30P650 -
Frothingham Electronics Corporation
The CV30 P650 test station is currently the highest voltage pulser in a series of exponential pulse generators that can be connected to our FEC200E tester. This gives you all the versatility of the proven FEC200 with the addition of high power exponential pulses. The CV30 P650 pulse adapter can produce a maximum current of 100A at up to 600V using exponential pulses up the 10/1000 waveform. The pulser is rated at 30KW from 300V to 650V. Voltage compliance at 100A is 600V. The station can also include all of the usual FEC200 tests in the same test program.
-
Applied Relay Testing Ltd.
When used in conjunction with ART's own parametric relay test systems such as the RT290, the RT900 offers high speed AC and DC Hipot (dielectric withstand voltage) and Leakage testing of relays or other multi-pin passive devices.
-
1132 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.
-
HH2009 -
Colluck Company Limited
Large LCD display 6000 count with symbolic signs. Auto Ranging High Voltage test up to 600V DC and 600V AC. Higher Current test up to 600A AC/DC. Continuity check. DC A zero adjust function. Low Battery Indication. Data Hold and Auto-Off Function
-
HH2205K -
Colluck Company Limited
Basic Accuracy 1.0%. Jumbo LCD display 2000 count, 23.5mm figure heigh. Manual Ranging at your choice (19 Range). Rated CAT II 1000V. High Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A (fuse protected)
-
HH2106 -
Colluck Company Limited
Basic Accuracy 1.2%. Jumbo LCD display 2000 count, 11mm figure height. Manual Ranging at your choice (6 Range). Manual Ranging at your choice. High Voltage test up to AC 500V and DC 200V. Resistance test up to 2000KΩ. Diode test. Independent 12V "A23" power supply
-
HH0308C -
Colluck Company Limited
Double Injection Casing. High Accuracy (basic accuracy 0.3%). 6000 count Jumbo LCD display with symbolic signs. Auto Ranging High Voltage test up to 1000V DC and 750V AC. Higher Current test up to 20A AC/DC. Diode and Continuity Check. Measure Resistance up to 60MΩ. Measure Temperature up to 300c. Measure Frequency up to 600k Hz
-
Keithley PCT -
Tektronix, Inc.
Developing and using MOSFETS, IGBTs, diodes and other high power devices requires comprehensive device-level characterization such as breakdown voltage, on-state current and capacitance measurements. Keithley's line of high power Parametric Curve Tracer configurations supports the full spectrum of device types and test parameters. Keithley's Parametric Curve Tracer configurations include everything necessary for the characterization engineer to develop a complete test system quickly.
-
IT6100 Series -
I-TECH Electronic Co., Ltd
IT6100 series assure you accurate measurements with 0.1mV/0.1mA high resolution and high accuracy. With high-speed List mode output and voltage rise speed up to 20ms, it can independently edit and perform the default voltage waveform to meet the high-speed test needs. IT6100 series has built-in 5 1/2 digital voltmeter and milliohm meter, which can measure additional signals. IT6100 series supports SCPI communication protocol, GPIB/USB/RS232 interfaces are optional for customers.
-
SCR ELEKTRONIKS
Electrical Safety is the most primary and essential product conformity requirement for any product that uses electricity. The clauses of safety testing of electrical products laid by worldwide agencies such as UL, CE, BIS, etc. are stringent. The products need to pass through tests such as the high voltage test, insulation resistance test, earth bond test, leakage current test and so on. And to conform to such tests, SCR Elektroniks have developed for the testing of Geyser. In addition to the conventional safety tests, test for performance is also included.
-
Electromechanica, Inc.
The rail inverter test system uses a pulse test methodology to verify proper operation of the IGBT switching elements in a subway car motor control. The system is designed to verify proper commutation of the switching elements. A large capacitor bank allows testing at DC voltages up to 1kV and peak currents of up to 3kA into reactive loads.The system also integrates self test capabilities and safe-to-turn-on (STTO) diagnostics to ensure no gross faults are present prior to the application of high voltages. Further the system includes dielectric withstand (hi-pot) test capability to ensure electrical safety.
-
M9185A -
Keysight Technologies
The M9185A is a fully independent, isolated D/A converter that is capable of supplying high voltage levels in parallel of up to eight or sixteen channels. Each channel is able to output up to 16V as stimulus signals to Device Under Tests (DUTs).