High Definition TV
Digital broadcast television with higher resoultion than NTSC, SECAM and PAL.
-
Product
Digital Wattchman Monitor/Alarm Systems
Model 91091
-
The Coaxial Dynamics 'Digital Wattchman' Rack Mounted Station Monitor/Alarm is similar in function and appearance to our 81090 Series except it is designed for the accurate measurement of complex RF Waveforms such as CDMA (Code Division Multiple Access), DAB (Digital Audio Broadcast), DTV (Digital TV) and HDTV (High Definition TV), as well as CW, AM and FM.
-
Product
75 Ohm HD Coax Contact
-
Ideal for video applications.Used for high definition TV transmission.Can be used in VPC hybrid iCon modules with 20/26 GHz contacts.
-
Product
High-Power Digital Wattmeters
-
The Coaxial Dynamics High-Power Digital Wattmeters are designed for the accurate measurement of complex RF Waveforms such as CDMA (Code Division Multiple Access), DAB (Digital Audio Broadcast), DTV (Digital TV) and HDTV (High Definition TV), as well as CW, AM and FM.
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
-
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
-
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
AC / DC Current Probe, 100 KHz, 100 A
1146B
-
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
Product
RF High Frequency Probes
-
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
High Current Probes for EV Battery Packs
-
Up to 500Amps - customized connections - battery pack charging.
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
-
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
-
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
DC Coupled Current Probe
34134A
-
Measure a wide range of applications with this battery-powered, clamp-on probe; use with DMMs or voltmeters
-
Product
High-Voltage Differential Probe, 200 MHz
N2805A
-
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
-
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
SHC68-C68-RDIO2, 68-Pin VHDCI Male to 68-Pin VHDCI Male, 80 MHz, Shielded Digital Cable, 2m
156166-02
-
SHC68-C68-RDIO2 Shielded R Series High Speed Digital Male VHDCI Cable, 2m
-
Product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
-
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
-
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
Alternate 24.00 (680.00) - 96.00 (2722.00) Godzilla High Current Probe
HC375F-6
-
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
SHC68-68-RDIO, 68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable, 1m
191667-01
-
68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable 1m
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
-
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
-
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Brute High Current Probe
P4301-2R
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
K-50 Series Probes
-
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
-
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
-
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
High-Voltage Differential Probe, 25 MHz
N2791A
-
Use the N2791A 25-MHz low-cost high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2791A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 700 V of differential voltage and common mode voltage.
-
Product
Brute Hight Current Probes
P4301
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
-
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
-
Your product description goes here.





























