Filter Results By:

Products

Applications

Manufacturers

Goniophotometers

measure the spatial distribution of sources of light.

See Also: Goniometers, Integrating Spheres


Showing results: 1 - 15 of 28 items found.

  • Goniophotometers

    Instrument Systems Optische Messtechnik GmbH

    All goniophotometers are designed as Type C with a horizontal alignment of the optical axis (turning luminaire configuration). Each goniometer sets benchmarks in its class for precision, reliability and handling. If these goniophotometers are combined with a spectroradiometer from Instrument Systems, they are able to determine not only photometric data but also spectral quantities, such as color coordinates, color temperature, and even color rendering index as a function of angle.

  • Goniophotometer

    PIMACS CO., LTD.

    A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.

  • Goniophotometer

    GMS2000 - OptCom Company, Ltd

    In this goniophotometer, the tested luminaire rotates in the prescribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously. The combined motion of the luminaire and mirror permit luminous measurement at the direction of any horizontal or vertical angle without tilting the luminaire, therefore, the luminous intensity will be not variation. The photometer head located at a fixed position of the limiting photomet- ric distance in front of the reflecting mirror to gather the light in each direction.

  • Goniophotometer

    Lisun Electronics Inc.

    A device used for measurement of the light emitted from an object at different angles

  • GONIOPHOTOMETER

    King Design Industrial Co., Ltd.

    Dual-mirror and Dual-detector Photometer for LED luminance test

  • Goniophotometers

    SphereOptics GmbH

    Goniometer has the capability not to only fit into almost every optical laboratory, but also to provide measurement data on concise level. The type C set up of this instrument enables the developer of single LEDs, LED modules or chips to study angular performance in many development stages; fast and most important: reliable. The detector head of the goniometer is a high-quality, visible-range spectrometer, equipped with diffuser optics to collect all important measurement quantities over the customer required angular range. With a maximum allowable source sample size of 300mmx100mm and 25kg, the new benchtop goniometer covers a wide range of LED measurement requirements. The footprint of the instrument itself with 1.65mx0.60mx1.73m allows the usage also in small dark rooms and optical laboratories.

  • Goniophotometer

    Hangzhou Hopoo Optoelectronics Technology Co., Ltd

    This system uses the method of fixing the detector and rotating the lamp under test to measure the light intensity distribution of the light source or lamp under test in all directions in the space. The main shaft and the lamp shaft adopt the conductive slip ring with precious metal fiber point brush structure, which can run 360 degrees continuously without backlash for measurement. There is no need to rotate back and forth to prevent winding and never winding. According to the requirements of the measuring lamps, the system can be configured as a double-column B-β test scheme or a single-column C-γ test scheme. Used for LED lamps (semiconductor lighting), road lamps, floodlights, indoor lamps, outdoor lamps, etc. and LED, energy-saving lamps, fluorescent lamps, incandescent lamps, HID lamps and other light sources of spatial luminosity distribution

  • Compact Goniophotometer

    LSG-1200A - Lisun Electronics Inc.

    The compact goniophotometer of LSG-1200A is used to measure the luminous intensity distribution curve, intensity data, spread angle and other parameters for Chip LED, LED Module, LED Spotlight and all other light which beam angle is no more than 180 degree. • Meets the requirements of IEC, CIE and LM-79 standards • Measures beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4 intensity angle and 1/10 intensity angle which meets the special requirements. • Measured data is matched with international standard form (IES) and can be applied for lighting design by other lighting design software such as DiaLux • LSG-1200A has included a dark room, measures the maximum size of lamps: 180mm • Test range of luminosity: 0.1~30,000lx. Test accuracy of detector: Class 1 • The distance between the tested lamp and detector is 316mm/1000mm • Angle interval: Horizontal angle: 1°/5°/10°/15°/22.5°/30°/45°/90°, Vertical angle: 0.5°/2°/1.5° • The LSG-1200A horizontal automatic rotating on 0°~360° and Vertical automatic rotating on -90°~+90° • Test accuracy of angle: ±0.2° Work with the follow instruments as a System

  • Near-field Goniophotometer

    RiGO801 - TechnoTeam Bildverarbeitung GmbH

    Correct determination of the luminous intensity distributions (lid) of lamps and luminaires far within their photometric near-field range. Capture of ray data.

  • Instrument Systems Goniophotometers

    Konica Minolta Sensing Americas, Inc

    If you need assistance measuring angle dependent spectral measurements, Instrument Systems has developed a comprehensive line of goniophotometers to meet your needs. Instrument Systems Goniophotometers are used to analyze angle dependent spatial radiation properties of SSL lamps and LED modules. Instrument Systems has two varieties of goniophotometers, one used for Large SSL lamps and LED modules as well as one designed for use in small to medium SSL Luminaries and LED modules. These instruments are capable of exporting data in an easily readable EULUMDAT format and provide exceptionally accurate measurement of luminous intensity distribution and luminous flux. The LGS 1000 model has an optional addition of a luminous flux integrator. Instrument Systems also offers a Type C Design for that particular goniophotometer model which is designed with a horizontal optical axis. This makes setting up a measuring path much simpler and allows measurements for specimens up to 1900mm in diameter.

  • Rotation Luminaire Goniophotometer

    LSG-1800 - Lisun Electronics Inc.

    LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.

  • LED Goniophotometer for Lamps

    880 - Shenzhen Chuangxin Instruments Co., Ltd.

    Be used to measure the luminous intensity distribution curve intensity data spread angle and equivalent luminous flux of luminaries. Computer controls the whole test process automatically with low cost and simple operations.

  • LM-79 Moving Detector Goniophotometer

    LSG-5000 - Lisun Electronics Inc.

    Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.

  • Goniophotometer for Traffic Signal Lamps

    LSG-1950S - Lisun Electronics Inc.

    LSG-1950S is a high automatic test system for luminous intensity distribution of luminaires and can be applied to quality evaluation and quality control for signal luminaires, luminaires for cars, motors, vessels and Retro-reflectors. LSG-1950S system is a goniophotometer which can measure all kinds of lamps and luminaires.• Rotations of test samples around both vertical axis (-90°~+90°) and horizontal axis (-35°~+35°) • Accuracy of angle: 0.1° • Resolution of angle: 0.01° • Photometer detector: CIE class A (standard class) accuracy • All software control, high intellectual faculties and simple operation

  • Light Distribution Photometer Goniophotometer

    LCG-1600 - Shenzhen Chuangxin Instruments Co., Ltd.

    LCG-1600 Goniophotometeric System carries out measuring methods of fixed location and rotating luminaires. The measured luminaire is installed on the two-dimension rotating table, using “+” laser to make the luminaire lighting center superposed with the rotating center of rotating table. The mechanical equipment allows turning the tested luminaires around a vertical axis and a horizontal axis. When tested luminaires turn around horizontal axis, the detector which is at the same level with rotating table will measure the intensity of each direction at this surface. When rotating with vertical axis, the detector will measure the intensity at the vertical surface. The vertical and horizontal axis can be rotated continuously at ±180° or 0~360°. According to the measurement requirements, the system can be operated in C-γ coordinates. When getting intensity distribution data, computer will calculate other photometric parameters automatically.