Filter Results By:

Products

Applications

Manufacturers

Gamma

Nuclear transition radiating a wavelength <1 pm and frequency (Hz) between 10 to the 20th and 10 to the 24th power.


Showing results: 91 - 102 of 102 items found.

  • Digital Multi Channel Analyzer

    DT5770 - CAEN S.p.A.

    The DT5770 is a compact portable 16k Digital MCA for Gamma Spectroscopy, integrating analog front-end with programmable gain and possible AC coupling. It is ideally suited for high energy resolution semiconductor detectors, like HPGe and Silicon, connected to a Charge Sensitive Preamplifier (CSP). The unit can also properly operate directly connected to a PMT with inorganic scintillators (e.g. Nal or Csl scintillators), provided exponential pulse shape and decay time above 200 ns.

  • Total Flux Measurement Systems

    Gamma Scientific Inc.

    LED’s and Luminaires must be characterized and tested for brightness and color, for production quality control and also for R&D. The Gamma Scientific Total Flux Measurement System combines our accurate Radoma Spectrometer and an integrating sphere for total flux (total power) and color measurements of LED, micro LED and Luminaires. Measurement parameters include spectrum, lumens, total power, peak and dominant wavelength, CRI, CCT, FWHM and other optical properties.

  • NED-LMD Near-Eye Display Measurement Systems

    NED-LMD WG Series - Gamma Scientific Inc.

    Gamma Scientific is introducing the NED-LMD Waveguide Tester as the world’s first specialized near-eye display measurement system that mimics human visual perception for fast, accurate and repeatable characterization of next generation optical waveguide-based Augmented/Mixed Reality displays and display components (light engine, waveguide, etc.). This comprehensive offering features a ‘robotic eye’ to help device manufacturers predict how the human eye would perceive their AR/MR displays, quantifying end user experience mapping the entire display field of view.

  • LED, Micro LED And VCSEL Measurement Systems

    Gamma Scientific Inc.

    With a track record spanning decades, Gamma Scientific is a leading provider of custom, high-precision light measurement solutions for LED, micro LED, and luminaires in both the laboratory and production environment.  The combination of our extensive competencies and commercial expertise has led to the development of a range of modular test solutions that can be readily integrated within the various phases of light source development and manufacturing. Each of these test modules includes measurement instrumentation, a system controller, all peripheral components, and top-level software interfaces.

  • Spectroscopic Personal Radiation Detector

    identiFINDER® R200 - Teledyne FLIR

    identiFINDER® R200 instruments are rugged, pager-sized Spectroscopic Personal Radiation Detectors (SPRD). They provide full ANSI N42.32 Personal Radiation Detector (PRD) compliance and feature next-generation solid state detector read-out technology that delivers ANSI N42.48 SPRD compliance with nuclide identification. The R200-G detects and identifies gamma radiation and the R200-GN additionally provides neutron detection capability. Law enforcement agencies and first responders use the R200 during routine traffic stops or high visibility events and in mass transit or critical infrastructure entry control points. The OneTouch Reachback™ feature uses the latest advancements in Bluetooth® and web server technologies to provide large-scale situational awareness by alerting others before arriving on-scene.

  • General Purpose Geiger Counter

    Radalert® 100X - International Medcom

    The Radalert® 100X is a general purpose geiger counter that measures alpha, beta, gamma, and X-radiation. Features of the Radalert® 100X, include a three-second update and a Utility Menu that allows you to change the default settings for several operating parameters. Its digital liquid crystal display (LCD) shows the current radiation level in your choice of SI units (microsieverts per hour) from .000 to 1,100 and counts per minute (CPM) from 0 to 350,000 or counts per second (CPS) from 0 to 3,500. For users of conventional units mR/hr (milliroentgens per hour) from .000 to 110 and CPM are optional in the Utility Menu. This instrument also offers an accumulated total and timer function, up to 9,999,000 counts and 40 hours.

  • Board Cameras

    e-con Systems Inc.

    e-CAM & See3CAM Series of Camera Boards. e-CAM camera board is e-con's reference design featuring a board camera interfaced to a processor on its high speed CMOS interface. Board cameras are available for Jetson Developer kits and NXP i.MX6 boards. For processors, that don't have the Camera ISP pipeline, e-con Systems provides the complete software stack for raw image sensors. The software stack has a wide variety of features ranging from color correction, gamma correction, dead pixel correction, color space conversion, sharpen filter etc.

  • Reflectance And Transmission Test Solutions

    Gamma Scientific Inc.

    Gamma Scientific provides unique, high-performance solutions for reflectance and transmission testing. These reflectivity measurement devices and light transmission testing systems capture complete spectral and colorimetric properties of thin film coatings with scan times typically less than one second. Uniquely, the 191F Specular Reflectometer can non-destructively measure first-surface reflectance on transparent substrates up to 0.3mm thick, with 100% exclusion of backside reflectance and no backside preparation or additional interference. Second-surface or second layer intermediate reflectance can also be characterized on intermediate surfaces by excluding reflectance from other surfaces within the substrate.

  • NIM-Modules

    FAST ComTec GmbH

    The "dual channel" TDC'''' - Model 7072T - converts time directly to a digital output. They offer improved performance and linearity specifications compared to separate TAC and ADC modules. There is also the Wilkinson-type ADC, Model 7070 which is suitable for high resolution HPGe detectors. Our Constant-Fraction discriminators are still state-of-the-art even after a more than 20 Year history. The Differential CFD - Model 7029A - still offers the highest counting rate (>50 MHz) of any such devices. Our Pulse-Shape Discriminator - Model 2160A - can be used to separate neutron and gamma particles, alphas and protons, electrons and alphas etc depending on the detector used.

  • Radiation Testers

    MRC ltd.

    The Ranger is a small, handheld, digital survey meter which offers excellent sensitivity to low levels of alpha, beta, gamma, and x-rays. It has built in efficiencies for common isotopes to calculate activity in Bq and DPM. It has a backlit display and a count light and abeeper that sounds with each count detected. Other features include selectable alert levels, an adjustable timer, and an optional wipe test plate. Internal memory and the free Observer USB Software allow you to download your data, set computer alarms, and calibrate your instrument! The Bluetooth and Observer BLE enables saving, sharing,and automation of surveys and RadResponder compatibility

  • Radiation Detectors

    PCE Instruments

    A radiation detector is a device for measuring nuclear, electromagnetic or light radiation. A nuclear radiation detector identifies nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a geiger counter, a nuclear radiation detector consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or nuclear radiation detector.

  • Radiation Microdosimeters

    Teledyne Defense Electronics

    Teledyne e2v HiRel Microdosimeter is a compact hybrid microcircuit which directly measures total ionizing dose (TID) absorbed by an internal silicon test mass. The test mass simulates silicon die of integrated circuits on-board a host spacecraft in critical mission payloads and subsystems. By accurately measuring the energy absorbed from electrons, protons, and gamma rays, an estimate of the dose absorbed by other electronic devices on the same vehicle can be made. The Microdosimeter can operate from a wide range of input voltages. The accumulated dose is presented to three dc linear outputs and one pseudo-logarithmic output giving a dose resolution of 14 µrads and a measurement range up to 40 krads. These outputs are intended to be directly connected to most analog-to-digital converters (ADCs) or spacecraft housekeeping analog inputs (0-5 V range), which makes minimal demands on the host vehicle. The Microdosimeter incorporates a test function to allow electrical testing of the hybrid without the need for a radiation source.

Get Help